CWE-1188

Initialization of a Resource with an Insecure Default

The product initializes or sets a resource with a default that is intended to be changed by the product's installer, administrator, or maintainer, but the default is not secure.

CVE-2025-2129 (GCVE-0-2025-2129)

Vulnerability from cvelistv5 – Published: 2025-03-09 20:00 – Updated: 2025-03-10 17:59 Disputed
VLAI
Title
Mage AI insecure default initialization of resource
Summary
A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecure default initialization of resource. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. After 7 months of repeated follow-ups by the researcher, Mage AI has decided to not accept this issue as a valid security vulnerability and has confirmed that they will not be addressing it.
SSVC
Exploitation: poc Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Insecure Default Initialization of Resource
Assigner
References
Impacted products
Vendor Product Version
n/a Mage AI Affected: 0.9.75
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2129",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-10T17:57:58.490863Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-10T17:59:05.752Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mage AI",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "0.9.75"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecure default initialization of resource. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. After 7 months of repeated follow-ups by the researcher, Mage AI has decided to not accept this issue as a valid security vulnerability and has confirmed that they will not be addressing it."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Mage AI 0.9.75 ausgemacht. Sie wurde als problematisch eingestuft. Betroffen hiervon ist ein unbekannter Ablauf. Durch die Manipulation mit unbekannten Daten kann eine insecure default initialization of resource-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Die Komplexit\u00e4t eines Angriffs ist eher hoch. Sie ist schwierig auszunutzen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung. Die wahre Existenz der vermeintlichen Schwachstelle wird zur Zeit in Frage gestellt."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.1,
            "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "Insecure Default Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-09T20:00:09.867Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-299049 | Mage AI insecure default initialization of resource",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.299049"
        },
        {
          "name": "VDB-299049 | CTI Indicators (IOB, IOC)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.299049"
        },
        {
          "name": "Submit #510690 | Mage AI Mage AI Framwork 0.9.75 Insecure Default Initialization of Resource",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.510690"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/zn9988/publications/blob/main/2.Mage-AI%20-%20Insecure%20Default%20Authentication%20Setup%20Leading%20to%20Zero-Click%20RCE/README.md"
        }
      ],
      "tags": [
        "disputed"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-03-09T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-03-09T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-03-09T07:58:35.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Mage AI insecure default initialization of resource"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-2129",
    "datePublished": "2025-03-09T20:00:09.867Z",
    "dateReserved": "2025-03-09T06:53:31.277Z",
    "dateUpdated": "2025-03-10T17:59:05.752Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2441 (GCVE-0-2025-2441)

Vulnerability from cvelistv5 – Published: 2025-04-09 10:23 – Updated: 2025-04-09 13:40
VLAI
Summary
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the product does not correctly initialize all data.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Insecure Default Initialization of Resource
Assigner
Impacted products
Vendor Product Version
Schneider Electric Trio Q Licensed Data Radio Affected: Versions prior to v2.7.2
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2441",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T13:38:22.617937Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-09T13:40:05.280Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Trio Q Licensed Data Radio",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to v2.7.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of\nconfidentiality when a malicious user, having physical access, sets the radio in factory default mode where the\nproduct does not correctly initialize all data.\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of\nconfidentiality when a malicious user, having physical access, sets the radio in factory default mode where the\nproduct does not correctly initialize all data."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "PHYSICAL",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Insecure Default Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-09T10:23:45.536Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-098-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-098-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2025-2441",
    "datePublished": "2025-04-09T10:23:45.536Z",
    "dateReserved": "2025-03-17T16:00:19.880Z",
    "dateUpdated": "2025-04-09T13:40:05.280Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2442 (GCVE-0-2025-2442)

Vulnerability from cvelistv5 – Published: 2025-04-09 10:26 – Updated: 2025-04-09 13:36
VLAI
Summary
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Insecure Default Initialization of Resource
Assigner
Impacted products
Vendor Product Version
Schneider Electric Trio Q Licensed Data Radio Affected: Versions prior to v2.7.2
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2442",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T13:27:12.458920Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-09T13:36:42.766Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Trio Q Licensed Data Radio",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to v2.7.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to\nunauthorized access which could result in the loss of confidentially, integrity and availability when a malicious\nuser, having physical access, sets the radio to the factory default mode.\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to\nunauthorized access which could result in the loss of confidentially, integrity and availability when a malicious\nuser, having physical access, sets the radio to the factory default mode."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "PHYSICAL",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Insecure Default Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-09T10:26:01.874Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-098-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-098-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2025-2442",
    "datePublished": "2025-04-09T10:26:01.874Z",
    "dateReserved": "2025-03-17T16:00:22.475Z",
    "dateUpdated": "2025-04-09T13:36:42.766Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-25271 (GCVE-0-2025-25271)

Vulnerability from cvelistv5 – Published: 2025-07-08 07:01 – Updated: 2025-07-22 07:50
VLAI
Title
OCPP Backend Configuration via Insecure Defaults
Summary
An unauthenticated adjacent attacker is able to configure a new OCPP backend, due to insecure defaults for the configuration interface.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Insecure Default Initialization of Resource
Assigner
References
Impacted products
Credits
Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-25271",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-08T14:23:31.539913Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-08T14:28:44.675Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CHARX SEC-3150",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "1.7.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CHARX SEC-3100",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "1.7.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CHARX SEC-3050",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "1.7.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CHARX SEC-3000",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "1.7.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated adjacent attacker is able to configure a new OCPP backend, due to insecure defaults for the configuration interface.\u003cbr\u003e"
            }
          ],
          "value": "An unauthenticated adjacent attacker is able to configure a new OCPP backend, due to insecure defaults for the configuration interface."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Insecure Default Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T07:50:50.592Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-019"
        }
      ],
      "source": {
        "advisory": "VDE-2025-019",
        "defect": [
          "CERT@VDE#641747"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "OCPP Backend Configuration via Insecure Defaults",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-25271",
    "datePublished": "2025-07-08T07:01:33.274Z",
    "dateReserved": "2025-02-06T13:19:38.484Z",
    "dateUpdated": "2025-07-22T07:50:50.592Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27443 (GCVE-0-2025-27443)

Vulnerability from cvelistv5 – Published: 2025-04-08 16:16 – Updated: 2025-04-08 20:32
VLAI
Title
Zoom Workplace Apps for Windows - Insecure Default Variable Initialization
Summary
Insecure default variable initialization in some Zoom Workplace Apps for Windows may allow an authenticated user to conduct a loss of integrity via local access.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Insecure Default Initialization of Resource
Assigner
Impacted products
Date Public
2025-04-08 12:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27443",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T20:32:03.387603Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T20:32:12.324Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "Zoom Workplace Apps for Windows",
          "vendor": "Zoom Communications, Inc",
          "versions": [
            {
              "status": "affected",
              "version": "See references.",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T12:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Insecure default variable initialization in some Zoom Workplace Apps for Windows may allow an authenticated user to conduct a loss of integrity via local access.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Insecure default variable initialization in some Zoom Workplace Apps for Windows may allow an authenticated user to conduct a loss of integrity via local access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 2.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Insecure Default Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T16:16:38.148Z",
        "orgId": "99b9af0d-a833-4a5d-9e2f-8b1324f35351",
        "shortName": "Zoom"
      },
      "references": [
        {
          "url": "https://www.zoom.com/en/trust/security-bulletin/zsb-25014"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Zoom Workplace Apps for Windows - Insecure Default Variable Initialization",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99b9af0d-a833-4a5d-9e2f-8b1324f35351",
    "assignerShortName": "Zoom",
    "cveId": "CVE-2025-27443",
    "datePublished": "2025-04-08T16:16:38.148Z",
    "dateReserved": "2025-02-25T18:35:04.401Z",
    "dateUpdated": "2025-04-08T20:32:12.324Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27809 (GCVE-0-2025-27809)

Vulnerability from cvelistv5 – Published: 2025-03-25 00:00 – Updated: 2025-03-25 16:49
VLAI
Summary
Mbed TLS before 2.28.10 and 3.x before 3.6.3, on the client side, accepts servers that have trusted certificates for arbitrary hostnames unless the TLS client application calls mbedtls_ssl_set_hostname.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Initialization of a Resource with an Insecure Default
Assigner
Impacted products
Vendor Product Version
Mbed mbedtls Affected: 0 , < 2.28.10 (semver)
Affected: 3.0.0 , < 3.6.3 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27809",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-25T14:41:49.022536Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-25T14:42:17.226Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-03-25T16:49:13.269Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://mastodon.social/@bagder/114219540623402700"
          },
          {
            "url": "https://github.com/Mbed-TLS/mbedtls/issues/466"
          }
        ],
        "title": "CVE Program Container",
        "x_generator": {
          "engine": "ADPogram 0.0.1"
        }
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "mbedtls",
          "vendor": "Mbed",
          "versions": [
            {
              "lessThan": "2.28.10",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThan": "3.6.3",
              "status": "affected",
              "version": "3.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mbed:mbedtls:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "2.28.10",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mbed:mbedtls:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "3.6.3",
                  "versionStartIncluding": "3.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Mbed TLS before 2.28.10 and 3.x before 3.6.3, on the client side, accepts servers that have trusted certificates for arbitrary hostnames unless the TLS client application calls mbedtls_ssl_set_hostname."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Initialization of a Resource with an Insecure Default",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-25T05:33:08.068Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Mbed-TLS/mbedtls/releases"
        },
        {
          "url": "https://mbed-tls.readthedocs.io/en/latest/security-advisories/mbedtls-security-advisory-2025-03-1/"
        }
      ],
      "x_generator": {
        "engine": "enrichogram 0.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-27809",
    "datePublished": "2025-03-25T00:00:00.000Z",
    "dateReserved": "2025-03-07T00:00:00.000Z",
    "dateUpdated": "2025-03-25T16:49:13.269Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-29985 (GCVE-0-2025-29985)

Vulnerability from cvelistv5 – Published: 2025-04-08 10:44 – Updated: 2025-04-08 13:02
VLAI
Summary
Dell Common Event Enabler, version(s) CEE 9.0.0.0, contain(s) an Initialization of a Resource with an Insecure Default vulnerability in the Common Anti-Virus Agent (CAVA). An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Initialization of a Resource with an Insecure Default
Assigner
References
Impacted products
Vendor Product Version
Dell Common Event Enabler Affected: N/A , < 9.0.0.0 (semver)
Create a notification for this product.
Date Public
2025-04-07 06:30
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-29985",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T13:02:32.508705Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T13:02:58.691Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Common Event Enabler",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.0.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-04-07T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Common Event Enabler, version(s) CEE 9.0.0.0, contain(s) an Initialization of a Resource with an Insecure Default vulnerability in the Common Anti-Virus Agent (CAVA). An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access.\u003cbr\u003e"
            }
          ],
          "value": "Dell Common Event Enabler, version(s) CEE 9.0.0.0, contain(s) an Initialization of a Resource with an Insecure Default vulnerability in the Common Anti-Virus Agent (CAVA). An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188: Initialization of a Resource with an Insecure Default",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T10:44:24.736Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000303931/dsa-2025-158-security-update-for-dell-common-event-enabler-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-29985",
    "datePublished": "2025-04-08T10:44:24.736Z",
    "dateReserved": "2025-03-13T05:03:56.322Z",
    "dateUpdated": "2025-04-08T13:02:58.691Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31930 (GCVE-0-2025-31930)

Vulnerability from cvelistv5 – Published: 2025-05-13 09:38 – Updated: 2025-05-13 14:46
VLAI
Summary
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Initialization of a Resource with an Insecure Default
Assigner
Impacted products
Vendor Product Version
Siemens IEC 1Ph 7.4kW Child socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 1Ph 7.4kW Child socket/ shutter Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 1Ph 7.4kW Parent cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 1Ph 7.4kW Parent cable 7m incl. SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 1Ph 7.4kW Parent socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 1Ph 7.4kW Parent socket incl. SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 1Ph 7.4kW Parent socket/ shutter Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 1Ph 7.4kW Parent socket/ shutter SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 3Ph 22kW Child cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 3Ph 22kW Child socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 3Ph 22kW Child socket/ shutter Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 3Ph 22kW Parent cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 3Ph 22kW Parent cable 7m incl. SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 3Ph 22kW Parent socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 3Ph 22kW Parent socket incl. SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 3Ph 22kW Parent socket/ shutter Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC 3Ph 22kW Parent socket/ shutter SIM Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC ERK 3Ph 22 kW Child cable 7m Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC ERK 3Ph 22 kW Child socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC ERK 3Ph 22 kW Parent socket Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens IEC ERK 3Ph 22 kW Parent socket incl. SI Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Cellular 48A NTEP Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Child 40A w/ 15118 HW Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Child 48A BA Compliant Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Child 48A w/ 15118 HW Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Parent 40A with Simcard Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Parent 48A (USPS) Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Parent 48A BA Compliant Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Parent 48A with Simcard BA Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Parent 48A, 15118, 25ft Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens UL Commercial Parent 48A,15118 25ft Sim Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Siemens VersiCharge Blue™ 80A AC Cellular Affected: 0 , < V2.135 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31930",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-13T14:18:38.660134Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-13T14:46:55.188Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Child socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Child socket/ shutter",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent cable 7m incl. SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent socket incl. SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent socket/ shutter",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 1Ph 7.4kW Parent socket/ shutter SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Child cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Child socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Child socket/ shutter",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent cable 7m incl. SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent socket incl. SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent socket/ shutter",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC 3Ph 22kW Parent socket/ shutter SIM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Child cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Child cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Child cable 7m",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Child socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Parent socket",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IEC ERK 3Ph 22 kW Parent socket incl. SI",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Cellular 48A NTEP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Child 40A w/ 15118 HW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Child 48A BA Compliant",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Child 48A w/ 15118 HW",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 40A with Simcard",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A (USPS)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A BA Compliant",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A with Simcard BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A, 15118, 25ft",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A, 15118, 25ft",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A, 15118, 25ft",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "UL Commercial Parent 48A,15118 25ft Sim",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "VersiCharge Blue\u2122 80A AC Cellular",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.135",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions \u003c V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions \u003c V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions \u003c V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions \u003c V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions \u003c V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions \u003c V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions \u003c V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions \u003c V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions \u003c V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions \u003c V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions \u003c V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions \u003c V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions \u003c V2.135), VersiCharge Blue\u2122 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions \u003c V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188: Initialization of a Resource with an Insecure Default",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-13T09:38:43.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-556937.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-31930",
    "datePublished": "2025-05-13T09:38:43.000Z",
    "dateReserved": "2025-04-01T16:45:21.675Z",
    "dateUpdated": "2025-05-13T14:46:55.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31974 (GCVE-0-2025-31974)

Vulnerability from cvelistv5 – Published: 2026-05-06 18:01 – Updated: 2026-05-06 18:32
VLAI
Title
HCL BigFix Service Management (SM) is susceptible to a Root File System Not Mounted as Read-Only
Summary
HCL BigFix Service Management (SM) is susceptible to a Root File System Not Mounted as Read-Only. An improperly configured root file system may allow unintended modifications to critical system components, potentially increasing the risk of system compromise or unauthorized changes.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Initialization of a resource with an insecure default
Assigner
HCL
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31974",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-06T18:32:03.589483Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-06T18:32:13.506Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "BigFix Service Management (SM)",
          "vendor": "HCL Software",
          "versions": [
            {
              "status": "affected",
              "version": "23"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "HCL BigFix Service Management (SM) is susceptible to a Root File System Not Mounted as Read-Only. An improperly configured root file system may allow\n\u003cbr\u003eunintended modifications to critical system components, potentially increasing the risk of system compromise or unauthorized changes."
            }
          ],
          "value": "HCL BigFix Service Management (SM) is susceptible to a Root File System Not Mounted as Read-Only. An improperly configured root file system may allow\n\nunintended modifications to critical system components, potentially increasing the risk of system compromise or unauthorized changes."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 3.9,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Initialization of a resource with an insecure default",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-06T18:01:39.794Z",
        "orgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
        "shortName": "HCL"
      },
      "references": [
        {
          "url": "https://support.hcl-software.com/csm?id=kb_article\u0026sysparm_article=KB0128144"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "HCL BigFix Service Management (SM) is susceptible to a Root File System Not Mounted as Read-Only",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
    "assignerShortName": "HCL",
    "cveId": "CVE-2025-31974",
    "datePublished": "2026-05-06T18:01:39.794Z",
    "dateReserved": "2025-04-01T18:46:26.620Z",
    "dateUpdated": "2026-05-06T18:32:13.506Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-35021 (GCVE-0-2025-35021)

Vulnerability from cvelistv5 – Published: 2025-11-04 00:23 – Updated: 2025-11-05 14:54
VLAI
Title
Abilis CPX Fallback Shell Connection Relay
Summary
By failing to authenticate three times to an unconfigured Abilis CPX device via SSH, an attacker can login to a restricted shell on the fourth attempt, and from there, relay connections.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-1188 - Insecure Default Initialization of Resource
Assigner
AHA
References
URL Tags
https://www.runzero.com/advisories/abilis-cpx-aut… technical-descriptionthird-party-advisory
https://takeonme.org/gcves/GCVE-1337-2025-0000000… technical-descriptionthird-party-advisory
https://support.abilis.net/relnotes/cpx2k/R9.0.ht… vendor-advisory
Impacted products
Vendor Product Version
Abilis CPX Affected: 0 , < 9.0.7 (semver)
Create a notification for this product.
Date Public
2025-11-04 00:06
Credits
HD Moore Tod Beardsley AHA!
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-35021",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-05T14:54:07.847887Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-05T14:54:15.000Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CPX",
          "vendor": "Abilis",
          "versions": [
            {
              "lessThan": "9.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "HD Moore"
        },
        {
          "lang": "en",
          "type": "reporter",
          "value": "Tod Beardsley"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "AHA!"
        }
      ],
      "datePublic": "2025-11-04T00:06:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "By failing to authenticate three times to an unconfigured Abilis CPX device via SSH, an attacker can login to a restricted shell on the fourth attempt, and from there, relay connections."
            }
          ],
          "value": "By failing to authenticate three times to an unconfigured Abilis CPX device via SSH, an attacker can login to a restricted shell on the fourth attempt, and from there, relay connections."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Insecure Default Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-04T14:55:16.723Z",
        "orgId": "26969f82-7e87-44d8-9cb5-f6fb926ddd43",
        "shortName": "AHA"
      },
      "references": [
        {
          "tags": [
            "technical-description",
            "third-party-advisory"
          ],
          "url": "https://www.runzero.com/advisories/abilis-cpx-authentication-bypass-cve-2025-35021/"
        },
        {
          "tags": [
            "technical-description",
            "third-party-advisory"
          ],
          "url": "https://takeonme.org/gcves/GCVE-1337-2025-00000000000000000000000000000000000000000000000001011111111111011111111110000000000000000000000000000000000000000000000000000000100"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://support.abilis.net/relnotes/cpx2k/R9.0.html#R9.0.7"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Abilis CPX Fallback Shell Connection Relay",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "26969f82-7e87-44d8-9cb5-f6fb926ddd43",
    "assignerShortName": "AHA",
    "cveId": "CVE-2025-35021",
    "datePublished": "2025-11-04T00:23:23.924Z",
    "dateReserved": "2025-04-15T20:40:32.308Z",
    "dateUpdated": "2025-11-05T14:54:15.000Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

No mitigation information available for this CWE.

CAPEC-665: Exploitation of Thunderbolt Protection Flaws

An adversary leverages a firmware weakness within the Thunderbolt protocol, on a computing device to manipulate Thunderbolt controller firmware in order to exploit vulnerabilities in the implementation of authorization and verification schemes within Thunderbolt protection mechanisms. Upon gaining physical access to a target device, the adversary conducts high-level firmware manipulation of the victim Thunderbolt controller SPI (Serial Peripheral Interface) flash, through the use of a SPI Programing device and an external Thunderbolt device, typically as the target device is booting up. If successful, this allows the adversary to modify memory, subvert authentication mechanisms, spoof identities and content, and extract data and memory from the target device. Currently 7 major vulnerabilities exist within Thunderbolt protocol with 9 attack vectors as noted in the Execution Flow.

Back to CWE stats page