CWE-121

Stack-based Buffer Overflow

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

CVE-2024-4116 (GCVE-0-2024-4116)

Vulnerability from cvelistv5 – Published: 2024-04-24 16:00 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E DelDhcpRule formDelDhcpRule stack-based overflow
Summary
A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this vulnerability is the function formDelDhcpRule of the file /goform/DelDhcpRule. The manipulation of the argument delDhcpIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261859. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261859 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261859 signaturepermissions-required
https://vuldb.com/?submit.317819 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e Affected: 15.11.0.14
    cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w15e",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.14"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4116",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-17T13:31:11.940050Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-17T13:32:48.261Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.131Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261859 | Tenda W15E DelDhcpRule formDelDhcpRule stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261859"
          },
          {
            "name": "VDB-261859 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261859"
          },
          {
            "name": "Submit #317819 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317819"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this vulnerability is the function formDelDhcpRule of the file /goform/DelDhcpRule. The manipulation of the argument delDhcpIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261859. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda W15E 15.11.0.14 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion formDelDhcpRule der Datei /goform/DelDhcpRule. Durch Manipulation des Arguments delDhcpIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T16:00:04.851Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261859 | Tenda W15E DelDhcpRule formDelDhcpRule stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261859"
        },
        {
          "name": "VDB-261859 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261859"
        },
        {
          "name": "Submit #317819 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317819"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:46.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E DelDhcpRule formDelDhcpRule stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4116",
    "datePublished": "2024-04-24T16:00:04.851Z",
    "dateReserved": "2024-04-24T08:18:59.156Z",
    "dateUpdated": "2024-08-01T20:33:52.131Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41166 (GCVE-0-2024-41166)

Vulnerability from cvelistv5 – Published: 2025-02-12 21:20 – Updated: 2025-02-13 19:46
VLAI
Summary
Stack-based buffer overflow in some Intel(R) PROSet/Wireless WiFi and Killerâ„¢ WiFi software for Windows before version 23.80 may allow an unauthenticated user to potentially enable denial of service via adjacent access.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • Denial of Service
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
n/a Intel(R) PROSet/Wireless WiFi and Killer(TM) WiFi software for Windows Affected: before version 23.80
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-41166",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-13T19:46:47.656960Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-13T19:46:54.348Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) PROSet/Wireless WiFi and Killer(TM) WiFi software for Windows",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version 23.80"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow in some Intel(R) PROSet/Wireless WiFi and Killer\u00e2\u201e\u00a2 WiFi software for Windows before version 23.80 may allow an unauthenticated user to potentially enable denial of service via adjacent access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "cvssV4_0": {
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Denial of Service",
              "lang": "en"
            },
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-12T21:20:07.730Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://intel.com/content/www/us/en/security-center/advisory/intel-sa-01224.html",
          "url": "https://intel.com/content/www/us/en/security-center/advisory/intel-sa-01224.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2024-41166",
    "datePublished": "2025-02-12T21:20:07.730Z",
    "dateReserved": "2024-07-17T03:00:05.100Z",
    "dateUpdated": "2025-02-13T19:46:54.348Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4117 (GCVE-0-2024-4117)

Vulnerability from cvelistv5 – Published: 2024-04-24 16:00 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E DelPortMapping formDelPortMapping stack-based overflow
Summary
A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261860 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261860 signaturepermissions-required
https://vuldb.com/?submit.317822 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4117",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T18:29:38.163596Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:54:28.292Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.356Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261860 | Tenda W15E DelPortMapping formDelPortMapping stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261860"
          },
          {
            "name": "VDB-261860 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261860"
          },
          {
            "name": "Submit #317822 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317822"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelPortMapping.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda W15E 15.11.0.14 gefunden. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion formDelPortMapping der Datei /goform/DelPortMapping. Mittels dem Manipulieren des Arguments portMappingIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T16:00:06.374Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261860 | Tenda W15E DelPortMapping formDelPortMapping stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261860"
        },
        {
          "name": "VDB-261860 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261860"
        },
        {
          "name": "Submit #317822 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317822"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelPortMapping.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:47.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E DelPortMapping formDelPortMapping stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4117",
    "datePublished": "2024-04-24T16:00:06.374Z",
    "dateReserved": "2024-04-24T08:19:01.960Z",
    "dateUpdated": "2024-08-01T20:33:52.356Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41170 (GCVE-0-2024-41170)

Vulnerability from cvelistv5 – Published: 2024-09-10 09:36 – Updated: 2024-09-10 15:08
VLAI
Summary
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0015), Tecnomatix Plant Simulation V2404 (All versions < V2404.0004). The affected applications contain a stack based overflow vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Siemens Tecnomatix Plant Simulation V2302 Affected: 0 , < V2302.0015 (custom)
Create a notification for this product.
Siemens Tecnomatix Plant Simulation V2404 Affected: 0 , < V2404.0004 (custom)
Create a notification for this product.
siemens tecnomatix_plant_simulation Affected: 2302.0 , < 2302.0015 (custom)
Affected: 2404.0 , < 2404.0004 (custom)
    cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tecnomatix_plant_simulation",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "2302.0015",
                "status": "affected",
                "version": "2302.0",
                "versionType": "custom"
              },
              {
                "lessThan": "2404.0004",
                "status": "affected",
                "version": "2404.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-41170",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-10T15:04:15.592651Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-10T15:08:25.467Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2302",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2302.0015",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Tecnomatix Plant Simulation V2404",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2404.0004",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0015), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0004). The affected applications contain a stack based overflow vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:36:44.999Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-427715.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-41170",
    "datePublished": "2024-09-10T09:36:44.999Z",
    "dateReserved": "2024-07-17T09:39:41.088Z",
    "dateUpdated": "2024-09-10T15:08:25.467Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4118 (GCVE-0-2024-4118)

Vulnerability from cvelistv5 – Published: 2024-04-24 16:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E addIpMacBind formIPMacBindAdd stack-based overflow
Summary
A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. This affects the function formIPMacBindAdd of the file /goform/addIpMacBind. The manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261861 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261861 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261861 signaturepermissions-required
https://vuldb.com/?submit.317823 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e_firmware Affected: 15.11.0.14
    cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w15e_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.14"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4118",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-30T19:39:38.857222Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:54:54.700Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.765Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261861 | Tenda W15E addIpMacBind formIPMacBindAdd stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261861"
          },
          {
            "name": "VDB-261861 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261861"
          },
          {
            "name": "Submit #317823 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317823"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formIPMacBindAdd.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. This affects the function formIPMacBindAdd of the file /goform/addIpMacBind. The manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261861 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda W15E 15.11.0.14 ausgemacht. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion formIPMacBindAdd der Datei /goform/addIpMacBind. Mittels Manipulieren des Arguments IPMacBindRule mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T16:31:04.948Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261861 | Tenda W15E addIpMacBind formIPMacBindAdd stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261861"
        },
        {
          "name": "VDB-261861 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261861"
        },
        {
          "name": "Submit #317823 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317823"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formIPMacBindAdd.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:49.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E addIpMacBind formIPMacBindAdd stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4118",
    "datePublished": "2024-04-24T16:31:04.948Z",
    "dateReserved": "2024-04-24T08:19:04.626Z",
    "dateUpdated": "2024-08-01T20:33:52.765Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4119 (GCVE-0-2024-4119)

Vulnerability from cvelistv5 – Published: 2024-04-24 17:00 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E delIpMacBind formIPMacBindDel stack-based overflow
Summary
A vulnerability was found in Tenda W15E 15.11.0.14. It has been declared as critical. This vulnerability affects the function formIPMacBindDel of the file /goform/delIpMacBind. The manipulation of the argument IPMacBindIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261862 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261862 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261862 signaturepermissions-required
https://vuldb.com/?submit.317824 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e Affected: 15.11.0.14
    cpe:2.3:a:tenda:w15e:15.11.0.14:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:w15e:15.11.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w15e",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.14"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4119",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-09T16:02:07.050226Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:55:40.492Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.420Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261862 | Tenda W15E delIpMacBind formIPMacBindDel stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261862"
          },
          {
            "name": "VDB-261862 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261862"
          },
          {
            "name": "Submit #317824 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317824"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formIPMacBindDel.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda W15E 15.11.0.14. It has been declared as critical. This vulnerability affects the function formIPMacBindDel of the file /goform/delIpMacBind. The manipulation of the argument IPMacBindIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261862 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda W15E 15.11.0.14 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion formIPMacBindDel der Datei /goform/delIpMacBind. Durch das Manipulieren des Arguments IPMacBindIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T17:00:05.059Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261862 | Tenda W15E delIpMacBind formIPMacBindDel stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261862"
        },
        {
          "name": "VDB-261862 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261862"
        },
        {
          "name": "Submit #317824 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317824"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formIPMacBindDel.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:51.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E delIpMacBind formIPMacBindDel stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4119",
    "datePublished": "2024-04-24T17:00:05.059Z",
    "dateReserved": "2024-04-24T08:19:07.763Z",
    "dateUpdated": "2024-08-01T20:33:52.420Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4120 (GCVE-0-2024-4120)

Vulnerability from cvelistv5 – Published: 2024-04-24 17:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E modifyIpMacBind formIPMacBindModify stack-based overflow
Summary
A vulnerability was found in Tenda W15E 15.11.0.14. It has been rated as critical. This issue affects the function formIPMacBindModify of the file /goform/modifyIpMacBind. The manipulation of the argument IPMacBindRuleId/IPMacBindRuleIp/IPMacBindRuleMac/IPMacBindRuleRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261863. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261863 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261863 signaturepermissions-required
https://vuldb.com/?submit.317825 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e Affected: 15.11.0.14
    cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w15e",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.14"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4120",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-25T16:46:10.912613Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:53:58.385Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.505Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261863 | Tenda W15E modifyIpMacBind formIPMacBindModify stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261863"
          },
          {
            "name": "VDB-261863 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261863"
          },
          {
            "name": "Submit #317825 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317825"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formIPMacBindModify.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda W15E 15.11.0.14. It has been rated as critical. This issue affects the function formIPMacBindModify of the file /goform/modifyIpMacBind. The manipulation of the argument IPMacBindRuleId/IPMacBindRuleIp/IPMacBindRuleMac/IPMacBindRuleRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261863. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda W15E 15.11.0.14 ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formIPMacBindModify der Datei /goform/modifyIpMacBind. Durch Manipulieren des Arguments IPMacBindRuleId/IPMacBindRuleIp/IPMacBindRuleMac/IPMacBindRuleRemark mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T17:31:05.162Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261863 | Tenda W15E modifyIpMacBind formIPMacBindModify stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261863"
        },
        {
          "name": "VDB-261863 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261863"
        },
        {
          "name": "Submit #317825 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317825"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formIPMacBindModify.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:52.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E modifyIpMacBind formIPMacBindModify stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4120",
    "datePublished": "2024-04-24T17:31:05.162Z",
    "dateReserved": "2024-04-24T08:19:10.839Z",
    "dateUpdated": "2024-08-01T20:33:52.505Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4121 (GCVE-0-2024-4121)

Vulnerability from cvelistv5 – Published: 2024-04-24 18:00 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E formQOSRuleDel stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261864 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261864 signaturepermissions-required
https://vuldb.com/?submit.317826 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… related
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e_firmware Affected: 15.11.0.14
    cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w15e_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.14"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4121",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-30T15:08:58.999891Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:54:46.614Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.570Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261864 | Tenda W15E formQOSRuleDel stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261864"
          },
          {
            "name": "VDB-261864 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261864"
          },
          {
            "name": "Submit #317826 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317826"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda W15E 15.11.0.14 entdeckt. Betroffen hiervon ist die Funktion formQOSRuleDel. Durch das Beeinflussen des Arguments qosIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T18:00:06.618Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261864 | Tenda W15E formQOSRuleDel stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261864"
        },
        {
          "name": "VDB-261864 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261864"
        },
        {
          "name": "Submit #317826 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317826"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:53.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E formQOSRuleDel stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4121",
    "datePublished": "2024-04-24T18:00:06.618Z",
    "dateReserved": "2024-04-24T08:19:14.033Z",
    "dateUpdated": "2024-08-01T20:33:52.570Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4122 (GCVE-0-2024-4122)

Vulnerability from cvelistv5 – Published: 2024-04-24 18:00 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E setDebugCfg formSetDebugCfg stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Affected by this vulnerability is the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261865 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261865 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261865 signaturepermissions-required
https://vuldb.com/?submit.317827 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e Affected: -
    cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w15e",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4122",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-25T18:09:06.576874Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:54:59.902Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.409Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261865 | Tenda W15E setDebugCfg formSetDebugCfg stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261865"
          },
          {
            "name": "VDB-261865 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261865"
          },
          {
            "name": "Submit #317827 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317827"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetDebugCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Affected by this vulnerability is the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261865 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda W15E 15.11.0.14 wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion formSetDebugCfg der Datei /goform/setDebugCfg. Durch Beeinflussen des Arguments enable/level/module mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T18:00:08.424Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261865 | Tenda W15E setDebugCfg formSetDebugCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261865"
        },
        {
          "name": "VDB-261865 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261865"
        },
        {
          "name": "Submit #317827 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317827"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetDebugCfg.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E setDebugCfg formSetDebugCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4122",
    "datePublished": "2024-04-24T18:00:08.424Z",
    "dateReserved": "2024-04-24T08:19:16.994Z",
    "dateUpdated": "2024-08-01T20:33:52.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4123 (GCVE-0-2024-4123)

Vulnerability from cvelistv5 – Published: 2024-04-24 18:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E SetPortMapping formSetPortMapping stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261866 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261866 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261866 signaturepermissions-required
https://vuldb.com/?submit.317828 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4123",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T18:27:25.556651Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:55:36.175Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.416Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261866 | Tenda W15E SetPortMapping formSetPortMapping stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261866"
          },
          {
            "name": "VDB-261866 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261866"
          },
          {
            "name": "Submit #317828 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317828"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetPortMapping.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261866 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda W15E 15.11.0.14 entdeckt. Es geht hierbei um die Funktion formSetPortMapping der Datei /goform/SetPortMapping. Dank der Manipulation des Arguments portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T18:31:05.431Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261866 | Tenda W15E SetPortMapping formSetPortMapping stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261866"
        },
        {
          "name": "VDB-261866 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261866"
        },
        {
          "name": "Submit #317828 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317828"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetPortMapping.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:57.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E SetPortMapping formSetPortMapping stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4123",
    "datePublished": "2024-04-24T18:31:05.431Z",
    "dateReserved": "2024-04-24T08:19:19.690Z",
    "dateUpdated": "2024-08-01T20:33:52.416Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-10

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation

Phase: Architecture and Design

Description:

  • Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation

Phase: Implementation

Description:

  • Implement and perform bounds checking on input.
Mitigation

Phase: Implementation

Description:

  • Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.

Back to CWE stats page