CWE-121

Stack-based Buffer Overflow

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

CVE-2024-4124 (GCVE-0-2024-4124)

Vulnerability from cvelistv5 – Published: 2024-04-24 18:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E SetRemoteWebManage formSetRemoteWebManage stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261867. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261867 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261867 signaturepermissions-required
https://vuldb.com/?submit.317829 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e Affected: 15.11.0.14
    cpe:2.3:a:tenda:w15e:15.11.0.14:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:w15e:15.11.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "affected",
            "product": "w15e",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.14"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4124",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-09T16:00:13.187226Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:10.405Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.518Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261867 | Tenda W15E SetRemoteWebManage formSetRemoteWebManage stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261867"
          },
          {
            "name": "VDB-261867 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261867"
          },
          {
            "name": "Submit #317829 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317829"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetRemoteWebManage.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261867. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda W15E 15.11.0.14 gefunden. Es geht dabei um die Funktion formSetRemoteWebManage der Datei /goform/SetRemoteWebManage. Dank Manipulation des Arguments remoteIP mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T18:31:06.901Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261867 | Tenda W15E SetRemoteWebManage formSetRemoteWebManage stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261867"
        },
        {
          "name": "VDB-261867 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261867"
        },
        {
          "name": "Submit #317829 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317829"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetRemoteWebManage.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:58.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E SetRemoteWebManage formSetRemoteWebManage stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4124",
    "datePublished": "2024-04-24T18:31:06.901Z",
    "dateReserved": "2024-04-24T08:19:22.592Z",
    "dateUpdated": "2024-08-01T20:33:52.518Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4125 (GCVE-0-2024-4125)

Vulnerability from cvelistv5 – Published: 2024-04-24 19:00 – Updated: 2024-09-03 19:19
VLAI
Title
Tenda W15E setStaticRoute formSetStaticRoute stack-based overflow
Summary
A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. This vulnerability affects the function formSetStaticRoute of the file /goform/setStaticRoute. The manipulation of the argument staticRouteIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261868. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261868 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261868 signaturepermissions-required
https://vuldb.com/?submit.317830 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e_firmware Affected: 15.11.0.14
    cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.367Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261868 | Tenda W15E setStaticRoute formSetStaticRoute stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261868"
          },
          {
            "name": "VDB-261868 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261868"
          },
          {
            "name": "Submit #317830 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317830"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetStaticRoute.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w15e_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.14"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4125",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T16:22:30.607375Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-03T19:19:55.056Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. This vulnerability affects the function formSetStaticRoute of the file /goform/setStaticRoute. The manipulation of the argument staticRouteIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261868. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda W15E 15.11.0.14 wurde eine kritische Schwachstelle gefunden. Dabei geht es um die Funktion formSetStaticRoute der Datei /goform/setStaticRoute. Mit der Manipulation des Arguments staticRouteIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T19:00:05.576Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261868 | Tenda W15E setStaticRoute formSetStaticRoute stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261868"
        },
        {
          "name": "VDB-261868 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261868"
        },
        {
          "name": "Submit #317830 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317830"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetStaticRoute.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:59.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E setStaticRoute formSetStaticRoute stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4125",
    "datePublished": "2024-04-24T19:00:05.576Z",
    "dateReserved": "2024-04-24T08:19:25.474Z",
    "dateUpdated": "2024-09-03T19:19:55.056Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4126 (GCVE-0-2024-4126)

Vulnerability from cvelistv5 – Published: 2024-04-24 19:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E SetSysTimeCfg formSetSysTime stack-based overflow
Summary
A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. This issue affects the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument manualTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261869 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261869 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261869 signaturepermissions-required
https://vuldb.com/?submit.317831 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e_firmware Affected: 15.11.0.14
    cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w15e_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.14"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4126",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-30T16:19:23.773429Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:53:16.645Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.364Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261869 | Tenda W15E SetSysTimeCfg formSetSysTime stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261869"
          },
          {
            "name": "VDB-261869 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261869"
          },
          {
            "name": "Submit #317831 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317831"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetSysTime.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. This issue affects the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument manualTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261869 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda W15E 15.11.0.14 gefunden. Hierbei geht es um die Funktion formSetSysTime der Datei /goform/SetSysTimeCfg. Durch die Manipulation des Arguments manualTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T19:31:04.982Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261869 | Tenda W15E SetSysTimeCfg formSetSysTime stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261869"
        },
        {
          "name": "VDB-261869 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261869"
        },
        {
          "name": "Submit #317831 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317831"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetSysTime.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:25:02.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E SetSysTimeCfg formSetSysTime stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4126",
    "datePublished": "2024-04-24T19:31:04.982Z",
    "dateReserved": "2024-04-24T08:19:28.404Z",
    "dateUpdated": "2024-08-01T20:33:52.364Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4127 (GCVE-0-2024-4127)

Vulnerability from cvelistv5 – Published: 2024-04-24 19:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda W15E guestWifiRuleRefresh stack-based overflow
Summary
A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. Affected is the function guestWifiRuleRefresh. The manipulation of the argument qosGuestDownstream leads to stack-based buffer overflow. It is possible to launch the attack remotely. VDB-261870 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261870 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261870 signaturepermissions-required
https://vuldb.com/?submit.317832 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… related
Impacted products
Vendor Product Version
Tenda W15E Affected: 15.11.0.14
Create a notification for this product.
tenda w15e Affected: 15.11.0.14
    cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w15e",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.14"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4127",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-30T17:15:20.534508Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:53:38.517Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.421Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261870 | Tenda W15E guestWifiRuleRefresh stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261870"
          },
          {
            "name": "VDB-261870 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261870"
          },
          {
            "name": "Submit #317832 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317832"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/guestWifiRuleRefresh.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W15E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. Affected is the function guestWifiRuleRefresh. The manipulation of the argument qosGuestDownstream leads to stack-based buffer overflow. It is possible to launch the attack remotely. VDB-261870 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda W15E 15.11.0.14 ausgemacht. Es betrifft die Funktion guestWifiRuleRefresh. Durch Manipulation des Arguments qosGuestDownstream mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T19:31:06.560Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261870 | Tenda W15E guestWifiRuleRefresh stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261870"
        },
        {
          "name": "VDB-261870 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261870"
        },
        {
          "name": "Submit #317832 | Tenda W15EV1.0 V15.11.0.14 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317832"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/guestWifiRuleRefresh.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:25:03.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W15E guestWifiRuleRefresh stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4127",
    "datePublished": "2024-04-24T19:31:06.560Z",
    "dateReserved": "2024-04-24T08:19:31.277Z",
    "dateUpdated": "2024-08-01T20:33:52.421Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4164 (GCVE-0-2024-4164)

Vulnerability from cvelistv5 – Published: 2024-04-25 10:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda G3 ModifyPppAuthWhiteMac formModifyPppAuthWhiteMac stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.17(9502). This issue affects the function formModifyPppAuthWhiteMac of the file /goform/ModifyPppAuthWhiteMac. The manipulation of the argument pppoeServerWhiteMacIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261983. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261983 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261983 signaturepermissions-required
https://vuldb.com/?submit.318588 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda G3 Affected: 15.11.0.17(9502)
Create a notification for this product.
tenda g3 Affected: 15.11.0.17(9502)
    cpe:2.3:h:tenda:g3:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_tu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:g3:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "g3",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.17(9502)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4164",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-17T14:06:35.265836Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-17T14:08:11.828Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.490Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261983 | Tenda G3 ModifyPppAuthWhiteMac formModifyPppAuthWhiteMac stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261983"
          },
          {
            "name": "VDB-261983 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261983"
          },
          {
            "name": "Submit #318588 | Tenda G3 V15.11.0.17(9502) Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.318588"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/G3V15/formModifyPppAuthWhiteMac.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "G3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.17(9502)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.17(9502). This issue affects the function formModifyPppAuthWhiteMac of the file /goform/ModifyPppAuthWhiteMac. The manipulation of the argument pppoeServerWhiteMacIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261983. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda G3 15.11.0.17(9502) entdeckt. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formModifyPppAuthWhiteMac der Datei /goform/ModifyPppAuthWhiteMac. Durch das Manipulieren des Arguments pppoeServerWhiteMacIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T10:31:04.703Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261983 | Tenda G3 ModifyPppAuthWhiteMac formModifyPppAuthWhiteMac stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261983"
        },
        {
          "name": "VDB-261983 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261983"
        },
        {
          "name": "Submit #318588 | Tenda G3 V15.11.0.17(9502) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.318588"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/G3V15/formModifyPppAuthWhiteMac.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-25T06:46:10.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda G3 ModifyPppAuthWhiteMac formModifyPppAuthWhiteMac stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4164",
    "datePublished": "2024-04-25T10:31:04.703Z",
    "dateReserved": "2024-04-25T04:41:06.126Z",
    "dateUpdated": "2024-08-01T20:33:52.490Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4165 (GCVE-0-2024-4165)

Vulnerability from cvelistv5 – Published: 2024-04-25 11:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda G3 modifyDhcpRule stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.17(9502). Affected is the function modifyDhcpRule of the file /goform/modifyDhcpRule. The manipulation of the argument bindDhcpIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261984. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261984 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261984 signaturepermissions-required
https://vuldb.com/?submit.318589 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda G3 Affected: 15.11.0.17(9502)
Create a notification for this product.
tenda g3 Affected: 15.11.0.17 (9502)
    cpe:2.3:h:tenda:g3:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_tu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:g3:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "g3",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.11.0.17 (9502)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4165",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-25T17:54:13.026370Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:06.993Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.512Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261984 | Tenda G3 modifyDhcpRule stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261984"
          },
          {
            "name": "VDB-261984 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261984"
          },
          {
            "name": "Submit #318589 | Tenda G3 V15.11.0.17(9502) Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.318589"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/G3V15/modifyDhcpRule.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "G3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.17(9502)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.17(9502). Affected is the function modifyDhcpRule of the file /goform/modifyDhcpRule. The manipulation of the argument bindDhcpIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261984. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda G3 15.11.0.17(9502) gefunden. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion modifyDhcpRule der Datei /goform/modifyDhcpRule. Durch Manipulieren des Arguments bindDhcpIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T11:31:04.731Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261984 | Tenda G3 modifyDhcpRule stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261984"
        },
        {
          "name": "VDB-261984 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261984"
        },
        {
          "name": "Submit #318589 | Tenda G3 V15.11.0.17(9502) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.318589"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/G3V15/modifyDhcpRule.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-25T06:46:14.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda G3 modifyDhcpRule stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4165",
    "datePublished": "2024-04-25T11:31:04.731Z",
    "dateReserved": "2024-04-25T04:41:08.828Z",
    "dateUpdated": "2024-08-01T20:33:52.512Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4166 (GCVE-0-2024-4166)

Vulnerability from cvelistv5 – Published: 2024-04-25 11:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda 4G300 sub_41E858 stack-based overflow
Summary
A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261985 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261985 signaturepermissions-required
https://vuldb.com/?submit.318981 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… related
Impacted products
Vendor Product Version
Tenda 4G300 Affected: 1.01.42
Create a notification for this product.
tenda 4g300_firmware Affected: 1.01.42
    cpe:2.3:o:tenda:4g300_firmware:1.01.42:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:4g300_firmware:1.01.42:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "4g300_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.01.42"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4166",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-02T17:41:52.582061Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T15:24:06.576Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.527Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261985 | Tenda 4G300 sub_41E858 stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261985"
          },
          {
            "name": "VDB-261985 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261985"
          },
          {
            "name": "Submit #318981 | Tenda 4G300 V1.01.42 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.318981"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_41E858_GO.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "4G300",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.01.42"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda 4G300 1.01.42 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um die Funktion sub_41E858. Durch das Beeinflussen des Arguments GO/page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T11:31:06.063Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261985 | Tenda 4G300 sub_41E858 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261985"
        },
        {
          "name": "VDB-261985 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261985"
        },
        {
          "name": "Submit #318981 | Tenda 4G300 V1.01.42 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.318981"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_41E858_GO.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-25T06:46:18.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda 4G300 sub_41E858 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4166",
    "datePublished": "2024-04-25T11:31:06.063Z",
    "dateReserved": "2024-04-25T04:41:12.861Z",
    "dateUpdated": "2024-08-01T20:33:52.527Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4167 (GCVE-0-2024-4167)

Vulnerability from cvelistv5 – Published: 2024-04-25 12:00 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda 4G300 sub_422AA4 stack-based overflow
Summary
A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261986 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261986 signaturepermissions-required
https://vuldb.com/?submit.318983 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… related
Impacted products
Vendor Product Version
Tenda 4G300 Affected: 1.01.42
Create a notification for this product.
tenda 4g300 Affected: -
    cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "4g300",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4167",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-02T17:32:59.611346Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:53:19.796Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.666Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261986 | Tenda 4G300 sub_422AA4 stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261986"
          },
          {
            "name": "VDB-261986 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261986"
          },
          {
            "name": "Submit #318983 | Tenda 4G300 V1.01.42 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.318983"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_422AA4.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "4G300",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.01.42"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda 4G300 1.01.42 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion sub_422AA4. Durch Beeinflussen des Arguments year/month/day/hour/minute/second mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T12:00:05.316Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261986 | Tenda 4G300 sub_422AA4 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261986"
        },
        {
          "name": "VDB-261986 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261986"
        },
        {
          "name": "Submit #318983 | Tenda 4G300 V1.01.42 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.318983"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_422AA4.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-25T06:46:29.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda 4G300 sub_422AA4 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4167",
    "datePublished": "2024-04-25T12:00:05.316Z",
    "dateReserved": "2024-04-25T04:41:16.861Z",
    "dateUpdated": "2024-08-01T20:33:52.666Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4168 (GCVE-0-2024-4168)

Vulnerability from cvelistv5 – Published: 2024-04-25 12:00 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda 4G300 sub_4260F0 stack-based overflow
Summary
A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261987 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261987 signaturepermissions-required
https://vuldb.com/?submit.318987 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… related
Impacted products
Vendor Product Version
Tenda 4G300 Affected: 1.01.42
Create a notification for this product.
tenda 4g300 Affected: 1.01.42
    cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "4g300",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.01.42"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4168",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-26T18:36:21.833544Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:30.744Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.702Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261987 | Tenda 4G300 sub_4260F0 stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261987"
          },
          {
            "name": "VDB-261987 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261987"
          },
          {
            "name": "Submit #318987 | Tenda 4G300 V1.01.42 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.318987"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_4260F0.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "4G300",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.01.42"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda 4G300 1.01.42 ausgemacht. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion sub_4260F0. Dank der Manipulation des Arguments upfilen mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T12:00:06.832Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261987 | Tenda 4G300 sub_4260F0 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261987"
        },
        {
          "name": "VDB-261987 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261987"
        },
        {
          "name": "Submit #318987 | Tenda 4G300 V1.01.42 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.318987"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_4260F0.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-25T06:46:35.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda 4G300 sub_4260F0 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4168",
    "datePublished": "2024-04-25T12:00:06.832Z",
    "dateReserved": "2024-04-25T04:41:28.184Z",
    "dateUpdated": "2024-08-01T20:33:52.702Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4169 (GCVE-0-2024-4169)

Vulnerability from cvelistv5 – Published: 2024-04-25 12:31 – Updated: 2024-08-01 20:33
VLAI
Title
Tenda 4G300 sub_4279CC stack-based overflow
Summary
A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.261988 vdb-entrytechnical-description
https://vuldb.com/?ctiid.261988 signaturepermissions-required
https://vuldb.com/?submit.318988 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… related
Impacted products
Vendor Product Version
Tenda 4G300 Affected: 1.01.42
Create a notification for this product.
tenda 4g300 Affected: 1.01.42
    cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:4g300:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "4g300",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.01.42"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4169",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-25T16:16:36.621949Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:55:55.670Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.514Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261988 | Tenda 4G300 sub_4279CC stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261988"
          },
          {
            "name": "VDB-261988 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261988"
          },
          {
            "name": "Submit #318988 | Tenda 4G300 V1.01.42 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.318988"
          },
          {
            "tags": [
              "related",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_42775C.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "4G300",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.01.42"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda 4G300 1.01.42 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion sub_42775C/sub_4279CC. Dank Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T12:31:04.756Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261988 | Tenda 4G300 sub_4279CC stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261988"
        },
        {
          "name": "VDB-261988 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261988"
        },
        {
          "name": "Submit #318988 | Tenda 4G300 V1.01.42 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.318988"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/G3/4G300/sub_42775C.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-25T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-25T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-25T06:46:40.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda 4G300 sub_4279CC stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4169",
    "datePublished": "2024-04-25T12:31:04.756Z",
    "dateReserved": "2024-04-25T04:41:33.737Z",
    "dateUpdated": "2024-08-01T20:33:52.514Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-10

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation

Phase: Architecture and Design

Description:

  • Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation

Phase: Implementation

Description:

  • Implement and perform bounds checking on input.
Mitigation

Phase: Implementation

Description:

  • Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.

Back to CWE stats page