CWE-77

Improper Neutralization of Special Elements used in a Command ('Command Injection')

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

CVE-2025-23196 (GCVE-0-2025-23196)

Vulnerability from cvelistv5 – Published: 2025-01-21 21:23 – Updated: 2025-02-03 08:22
VLAI
Title
Apache Ambari: Code Injection Vulnerability in Ambari Alert Definition
Summary
A code injection vulnerability exists in the Ambari Alert Definition feature, allowing authenticated users to inject and execute arbitrary shell commands. The vulnerability arises when defining alert scripts, where the script filename field is executed using `sh -c`. An attacker with authenticated access can exploit this vulnerability to inject malicious commands, leading to remote code execution on the server. The issue has been fixed in the latest versions of Ambari.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
Apache Software Foundation Apache Ambari Affected: 8 , < 2.7.9 (semver)
Create a notification for this product.
Credits
Liyw979 robinzeng2015 fcgboy wk2025 Tari from Sangfor Company
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-01-21T23:02:44.790Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://www.openwall.com/lists/oss-security/2025/01/21/8"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-23196",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-22T14:47:59.283725Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-22T14:48:12.311Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Apache Ambari",
          "vendor": "Apache Software Foundation",
          "versions": [
            {
              "lessThan": "2.7.9",
              "status": "affected",
              "version": "8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Liyw979"
        },
        {
          "lang": "en",
          "type": "reporter",
          "value": "robinzeng2015"
        },
        {
          "lang": "en",
          "type": "reporter",
          "value": "fcgboy"
        },
        {
          "lang": "en",
          "type": "reporter",
          "value": "wk2025"
        },
        {
          "lang": "en",
          "type": "reporter",
          "value": "Tari from Sangfor Company"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A code injection vulnerability exists in the Ambari Alert Definition \nfeature, allowing authenticated users to inject and execute arbitrary \nshell commands. The vulnerability arises when defining alert scripts, \nwhere the script filename field is executed using `sh -c`. An attacker \nwith authenticated access can exploit this vulnerability to inject \nmalicious commands, leading to remote code execution on the server. The \nissue has been fixed in the latest versions of Ambari."
            }
          ],
          "value": "A code injection vulnerability exists in the Ambari Alert Definition \nfeature, allowing authenticated users to inject and execute arbitrary \nshell commands. The vulnerability arises when defining alert scripts, \nwhere the script filename field is executed using `sh -c`. An attacker \nwith authenticated access can exploit this vulnerability to inject \nmalicious commands, leading to remote code execution on the server. The \nissue has been fixed in the latest versions of Ambari."
        }
      ],
      "metrics": [
        {
          "other": {
            "content": {
              "text": "important"
            },
            "type": "Textual description of severity"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-03T08:22:56.454Z",
        "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
        "shortName": "apache"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://lists.apache.org/thread/70g1l5lxvko7kvhyxmtmklhhfrlon837"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Apache Ambari: Code Injection Vulnerability in Ambari Alert Definition",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
    "assignerShortName": "apache",
    "cveId": "CVE-2025-23196",
    "datePublished": "2025-01-21T21:23:41.389Z",
    "dateReserved": "2025-01-13T14:43:54.173Z",
    "dateUpdated": "2025-02-03T08:22:56.454Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-23239 (GCVE-0-2025-23239)

Vulnerability from cvelistv5 – Published: 2025-02-05 17:31 – Updated: 2026-02-26 19:09
VLAI
Title
BIG-IP iControl REST vulnerability
Summary
When running in Appliance mode, and logged into a highly-privileged role, an authenticated remote command injection vulnerability exists in an undisclosed iControl REST endpoint. A successful exploit can allow the attacker to cross a security boundary. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
f5
References
Impacted products
Vendor Product Version
F5 BIG-IP Affected: 17.1.1 , < 17.1.2 (custom)
Unaffected: 16.1.0 , < * (custom)
Unaffected: 15.1.0 , < * (custom)
Create a notification for this product.
Date Public
2025-02-05 15:00
Credits
F5
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23239",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-06T04:55:25.457568Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T19:09:23.346Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "modules": [
            "All Modules"
          ],
          "product": "BIG-IP",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "17.1.2",
              "status": "affected",
              "version": "17.1.1",
              "versionType": "custom"
            },
            {
              "lessThan": "*",
              "status": "unaffected",
              "version": "16.1.0",
              "versionType": "custom"
            },
            {
              "lessThan": "*",
              "status": "unaffected",
              "version": "15.1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "F5"
        }
      ],
      "datePublic": "2025-02-05T15:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWhen running in Appliance mode, and logged into a highly-privileged role, an authenticated remote command injection vulnerability exists in an undisclosed iControl REST endpoint. A successful exploit can allow the attacker to cross a security boundary.\u003c/span\u003e\u003c/span\u003e\n\n \n\n\nNote: Software versions which have reached End of Technical Support (EoTS) are not evaluated."
            }
          ],
          "value": "When running in Appliance mode, and logged into a highly-privileged role, an authenticated remote command injection vulnerability exists in an undisclosed iControl REST endpoint. A successful exploit can allow the attacker to cross a security boundary.\n\n \n\n\nNote: Software versions which have reached End of Technical Support (EoTS) are not evaluated."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-03T00:39:58.310Z",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://my.f5.com/manage/s/article/K000138757"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "BIG-IP iControl REST vulnerability",
      "x_generator": {
        "engine": "F5 SIRTBot v1.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2025-23239",
    "datePublished": "2025-02-05T17:31:03.286Z",
    "dateReserved": "2025-01-22T00:16:50.328Z",
    "dateUpdated": "2026-02-26T19:09:23.346Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-2367 (GCVE-0-2025-2367)

Vulnerability from cvelistv5 – Published: 2025-03-17 07:31 – Updated: 2025-03-17 14:28
VLAI
Title
Oiwtech OIW-2431APGN-HP Personal Script Submenu formScript os command injection
Summary
A vulnerability has been found in Oiwtech OIW-2431APGN-HP 2.5.3-B20131128 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formScript of the component Personal Script Submenu. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.299866 vdb-entry
https://vuldb.com/?ctiid.299866 signaturepermissions-required
https://vuldb.com/?submit.515126 third-party-advisory
Impacted products
Vendor Product Version
Oiwtech OIW-2431APGN-HP Affected: 2.5.3-B20131128
Create a notification for this product.
Credits
Havook (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2367",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-17T14:28:04.477064Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-17T14:28:33.312Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Personal Script Submenu"
          ],
          "product": "OIW-2431APGN-HP",
          "vendor": "Oiwtech",
          "versions": [
            {
              "status": "affected",
              "version": "2.5.3-B20131128"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Havook (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Oiwtech OIW-2431APGN-HP 2.5.3-B20131128 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formScript of the component Personal Script Submenu. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Oiwtech OIW-2431APGN-HP 2.5.3-B20131128 wurde eine kritische Schwachstelle gefunden. Das betrifft eine unbekannte Funktionalit\u00e4t der Datei /boafrm/formScript der Komponente Personal Script Submenu. Mittels Manipulieren mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-17T07:31:03.916Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-299866 | Oiwtech OIW-2431APGN-HP Personal Script Submenu formScript os command injection",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.299866"
        },
        {
          "name": "VDB-299866 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.299866"
        },
        {
          "name": "Submit #515126 | Oiwtech OIWTECH-OIW-2431APGN-HP-V2.5.3-B20131128 v2.5.3 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.515126"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-03-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-03-16T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-03-16T13:24:37.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Oiwtech OIW-2431APGN-HP Personal Script Submenu formScript os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-2367",
    "datePublished": "2025-03-17T07:31:03.916Z",
    "dateReserved": "2025-03-16T12:19:33.933Z",
    "dateUpdated": "2025-03-17T14:28:33.312Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-24049 (GCVE-0-2025-24049)

Vulnerability from cvelistv5 – Published: 2025-03-11 16:59 – Updated: 2026-02-13 19:39
VLAI
Title
Azure Command Line Integration (CLI) Elevation of Privilege Vulnerability
Summary
Improper neutralization of special elements used in a command ('command injection') in Azure Command Line Integration (CLI) allows an unauthorized attacker to elevate privileges locally.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Microsoft Azure CLI Affected: 2.0.0 , < 2.69.0 (custom)
Create a notification for this product.
Date Public
2025-03-11 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-24049",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T18:25:32.882728Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T18:29:46.282Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Azure CLI",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "2.69.0",
              "status": "affected",
              "version": "2.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:azure_command-line_interface:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "2.69.0",
                  "versionStartIncluding": "2.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2025-03-11T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Improper neutralization of special elements used in a command (\u0027command injection\u0027) in Azure Command Line Integration (CLI) allows an unauthorized attacker to elevate privileges locally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-13T19:39:06.152Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Azure Command Line Integration (CLI) Elevation of Privilege Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2025-24049"
        }
      ],
      "title": "Azure Command Line Integration (CLI) Elevation of Privilege Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2025-24049",
    "datePublished": "2025-03-11T16:59:21.485Z",
    "dateReserved": "2025-01-16T23:11:19.732Z",
    "dateUpdated": "2026-02-13T19:39:06.152Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-24861 (GCVE-0-2025-24861)

Vulnerability from cvelistv5 – Published: 2025-02-13 21:20 – Updated: 2025-02-14 15:47
VLAI
Title
Outback Power Mojave Inverter Command Injection
Summary
An attacker may inject commands via specially-crafted post requests.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
Outback Power Mojave Inverter Affected: All versions
Create a notification for this product.
Credits
Jon Hurtado of Sandia National Laboratory reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-24861",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-14T15:37:12.816629Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-14T15:47:37.776Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Mojave Inverter",
          "vendor": "Outback Power",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jon Hurtado of Sandia National Laboratory reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An attacker may inject commands via specially-crafted post requests."
            }
          ],
          "value": "An attacker may inject commands via specially-crafted post requests."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-13T21:20:05.837Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-044-17"
        },
        {
          "url": "https://old.outbackpower.com/about-outback/contact/contact-us"
        }
      ],
      "source": {
        "advisory": "ICSA-25-044-17",
        "discovery": "EXTERNAL"
      },
      "title": "Outback Power Mojave Inverter Command Injection",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The Mojave Inverter was a product of Enersys. When Outback Power was \nsplit off from Enersys recently, Mojave Inverter was moved to Outback \nPower, but without the resources to maintain the product. Outback Power \nmay discontinue this product and has not yet addressed these \nvulnerabilities. CISA recommends disabling the networking features of \nthis product until a replacement product can be acquired.\n\n\u003cbr\u003e"
            }
          ],
          "value": "The Mojave Inverter was a product of Enersys. When Outback Power was \nsplit off from Enersys recently, Mojave Inverter was moved to Outback \nPower, but without the resources to maintain the product. Outback Power \nmay discontinue this product and has not yet addressed these \nvulnerabilities. CISA recommends disabling the networking features of \nthis product until a replacement product can be acquired."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-24861",
    "datePublished": "2025-02-13T21:20:05.837Z",
    "dateReserved": "2025-02-12T16:21:30.233Z",
    "dateUpdated": "2025-02-14T15:47:37.776Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-26331 (GCVE-0-2025-26331)

Vulnerability from cvelistv5 – Published: 2025-03-07 08:06 – Updated: 2026-02-26 19:09
VLAI
Summary
Dell ThinOS 2411 and prior, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell Wyse Proprietary OS (Modern ThinOS) Affected: N/A , < ThinOS 2502 (semver)
Create a notification for this product.
Date Public
2025-03-04 06:30
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26331",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T03:55:18.145197Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T19:09:44.393Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://www.incibe.es/incibe-cert/alerta-temprana/vulnerabilidades/cve-2025-26331"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "ThinOS",
            "Latitude 3420",
            "Latitude 3440",
            "Latitude 5440",
            "Latitude 5450",
            "OptiPlex 3000 Thin Client",
            "OptiPlex 5400 All-in-One",
            "OptiPlex AIO 7410",
            "OptiPlex AIO 7420",
            "Wyse 5070 Thin Client",
            "Wyse 5470 All-in-One Thin Client",
            "Wyse 5470 Mobile Thin Client"
          ],
          "product": "Wyse Proprietary OS (Modern ThinOS)",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "ThinOS 2502",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-03-04T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell ThinOS 2411 and prior, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.\u003cbr\u003e"
            }
          ],
          "value": "Dell ThinOS 2411 and prior, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-07T08:06:12.680Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000289886/dsa-2025-107"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-26331",
    "datePublished": "2025-03-07T08:06:12.680Z",
    "dateReserved": "2025-02-07T06:04:04.738Z",
    "dateUpdated": "2026-02-26T19:09:44.393Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26385 (GCVE-0-2025-26385)

Vulnerability from cvelistv5 – Published: 2026-01-30 11:05 – Updated: 2026-01-30 12:38
VLAI
Title
Metasys product command injection vulnerability could allow remote SQL execution
Summary
Johnson Controls Metasys component listed below have Improper Neutralization of Special Elements used in a Command (Command Injection) Vulnerability . Successful exploitation of this vulnerability could allow remote SQL execution This issue affects  * Metasys: Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation,  * Extended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation,  * LCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1,  * System Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior,  * Controller Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
jci
Impacted products
Vendor Product Version
Johnson Controls Metasys Affected: Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation (custom)
Affected: Extended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation (custom)
Affected: LCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1 (custom)
Affected: System Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior (custom)
Affected: Controller Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior (custom)
Create a notification for this product.
Date Public
2026-01-27 10:39
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26385",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T12:37:58.863009Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-30T12:38:11.405Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Application and Data Server (ADS)",
            "Extended Application and Data Server",
            "LCS8500 or NAE8500  (ADX)",
            "Controller Configuration Tool (CCT)",
            "System Configuration Tool (SCT)"
          ],
          "product": "Metasys",
          "vendor": "Johnson Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "Extended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "LCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "System Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "Controller Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2026-01-27T10:39:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u0026nbsp;Johnson Controls Metasys component listed below have  Improper Neutralization of Special Elements used in a Command (Command Injection) Vulnerability . Successful exploitation of this vulnerability could allow remote SQL execution \u003cp\u003eThis issue affects\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eMetasys: Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation,\u0026nbsp;\u003c/li\u003e\u003cli\u003eExtended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation,\u0026nbsp;\u003c/li\u003e\u003cli\u003eLCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1,\u0026nbsp;\u003c/li\u003e\u003cli\u003eSystem Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior,\u0026nbsp;\u003c/li\u003e\u003cli\u003eController Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Johnson Controls Metasys component listed below have  Improper Neutralization of Special Elements used in a Command (Command Injection) Vulnerability . Successful exploitation of this vulnerability could allow remote SQL execution This issue affects\u00a0\n\n\n\n  *  Metasys: Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation,\u00a0\n  *  Extended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation,\u00a0\n  *  LCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1,\u00a0\n  *  System Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior,\u00a0\n  *  Controller Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 9.5,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-30T11:05:16.688Z",
        "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "shortName": "jci"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-04"
        },
        {
          "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "a.  Follow the Johnson Controls hardening guide steps to ensure your Metasys installation is on a segmented network, not exposed to untrusted networks such as the internet\u003cbr\u003eb.  Download and execute the Metasys patch for GIV-165989 from the License Portal \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://software.jci.com/licenseportal/\"\u003ehttps://software.jci.com/licenseportal/\u003c/a\u003e.  Login credentials are required\u003cbr\u003ec.  Close incoming TCP port 1433\u003cbr\u003ed.  For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-02 at the following location: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.johnsoncontrols.com/cyber-solutions/security-advisories\"\u003ehttps://www.johnsoncontrols.com/cyber-solutions/security-advisories\u003c/a\u003e\u003cbr\u003e"
            }
          ],
          "value": "a.  Follow the Johnson Controls hardening guide steps to ensure your Metasys installation is on a segmented network, not exposed to untrusted networks such as the internet\nb.  Download and execute the Metasys patch for GIV-165989 from the License Portal  https://software.jci.com/licenseportal/ .  Login credentials are required\nc.  Close incoming TCP port 1433\nd.  For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-02 at the following location:  https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Metasys product command injection vulnerability could allow remote SQL execution",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
    "assignerShortName": "jci",
    "cveId": "CVE-2025-26385",
    "datePublished": "2026-01-30T11:05:16.688Z",
    "dateReserved": "2025-02-07T14:15:53.880Z",
    "dateUpdated": "2026-01-30T12:38:11.405Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-26627 (GCVE-0-2025-26627)

Vulnerability from cvelistv5 – Published: 2025-03-11 16:59 – Updated: 2026-02-13 19:39
VLAI
Title
Azure Arc Installer Elevation of Privilege Vulnerability
Summary
Improper neutralization of special elements used in a command ('command injection') in Azure Arc allows an authorized attacker to elevate privileges locally.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Microsoft Azure ARC Affected: 1.0.0 , < 1.0.10 (custom)
Create a notification for this product.
Date Public
2025-03-11 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26627",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T18:25:30.321392Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T18:28:36.722Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Azure ARC",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "1.0.10",
              "status": "affected",
              "version": "1.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:azure_arc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "1.0.10",
                  "versionStartIncluding": "1.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2025-03-11T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Improper neutralization of special elements used in a command (\u0027command injection\u0027) in Azure Arc allows an authorized attacker to elevate privileges locally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-13T19:39:06.783Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Azure Arc Installer Elevation of Privilege Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2025-26627"
        }
      ],
      "title": "Azure Arc Installer Elevation of Privilege Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2025-26627",
    "datePublished": "2025-03-11T16:59:22.159Z",
    "dateReserved": "2025-02-12T19:23:29.267Z",
    "dateUpdated": "2026-02-13T19:39:06.783Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-2701 (GCVE-0-2025-2701)

Vulnerability from cvelistv5 – Published: 2025-03-24 09:00 – Updated: 2025-03-24 12:04
VLAI
Title
AMTT Hotel Broadband Operation System port_setup.php popen os command injection
Summary
A vulnerability classified as critical was found in AMTT Hotel Broadband Operation System 1.0. This vulnerability affects the function popen of the file /manager/network/port_setup.php. The manipulation of the argument SwitchVersion/SwitchWrite/SwitchIP/SwitchIndex/SwitchState leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.300718 vdb-entrytechnical-description
https://vuldb.com/?ctiid.300718 signaturepermissions-required
https://vuldb.com/?submit.516089 third-party-advisory
https://github.com/zian10001/cve/blob/main/rce.md exploit
Impacted products
Credits
zianA (VulDB User) zianA (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2701",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-24T12:04:26.502205Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-24T12:04:44.527Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Hotel Broadband Operation System",
          "vendor": "AMTT",
          "versions": [
            {
              "status": "affected",
              "version": "1.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "zianA (VulDB User)"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "zianA (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in AMTT Hotel Broadband Operation System 1.0. This vulnerability affects the function popen of the file /manager/network/port_setup.php. The manipulation of the argument SwitchVersion/SwitchWrite/SwitchIP/SwitchIndex/SwitchState leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In AMTT Hotel Broadband Operation System 1.0 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion popen der Datei /manager/network/port_setup.php. Dank der Manipulation des Arguments SwitchVersion/SwitchWrite/SwitchIP/SwitchIndex/SwitchState mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-24T09:00:06.117Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-300718 | AMTT Hotel Broadband Operation System port_setup.php popen os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.300718"
        },
        {
          "name": "VDB-300718 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.300718"
        },
        {
          "name": "Submit #516089 | Anmei Century (Beijing) Technology Co., Ltd. Anmei Digital Hotel Broadband Operation System v1.0 Command Execution",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.516089"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/zian10001/cve/blob/main/rce.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-03-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-03-23T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-03-24T07:39:40.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "AMTT Hotel Broadband Operation System port_setup.php popen os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-2701",
    "datePublished": "2025-03-24T09:00:06.117Z",
    "dateReserved": "2025-03-23T18:09:07.506Z",
    "dateUpdated": "2025-03-24T12:04:44.527Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27146 (GCVE-0-2025-27146)

Vulnerability from cvelistv5 – Published: 2025-02-25 20:04 – Updated: 2025-02-25 20:33
VLAI
Title
Matrix IRC Bridge allows IRC command injection to own puppeted user
Summary
matrix-appservice-irc is a Node.js IRC bridge for Matrix. The matrix-appservice-irc bridge up to version 3.0.3 contains a vulnerability which can lead to arbitrary IRC command execution as the puppeted user. The attacker can only inject commands executed as their own IRC user. The vulnerability has been patched in matrix-appservice-irc version 3.0.4.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • CWE-88 - Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27146",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-25T20:30:53.918731Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-25T20:33:36.095Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "matrix-appservice-irc",
          "vendor": "matrix-org",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 3.0.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "matrix-appservice-irc is a Node.js IRC bridge for Matrix. The matrix-appservice-irc bridge up to version 3.0.3 contains a vulnerability which can lead to arbitrary IRC command execution as the puppeted user. The attacker can only inject commands executed as their own IRC user. The vulnerability has been patched in matrix-appservice-irc version 3.0.4."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-88",
              "description": "CWE-88: Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-25T20:04:40.400Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/matrix-org/matrix-appservice-irc/security/advisories/GHSA-5mvm-89c9-9gm5",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/matrix-org/matrix-appservice-irc/security/advisories/GHSA-5mvm-89c9-9gm5"
        },
        {
          "name": "https://github.com/matrix-org/matrix-appservice-irc/commit/74f02c8e11f16ed1b355700092c1aa9c036a11bd",
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/matrix-org/matrix-appservice-irc/commit/74f02c8e11f16ed1b355700092c1aa9c036a11bd"
        }
      ],
      "source": {
        "advisory": "GHSA-5mvm-89c9-9gm5",
        "discovery": "UNKNOWN"
      },
      "title": "Matrix IRC Bridge allows IRC command injection to own puppeted user"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2025-27146",
    "datePublished": "2025-02-25T20:04:40.400Z",
    "dateReserved": "2025-02-19T16:30:47.778Z",
    "dateUpdated": "2025-02-25T20:33:36.095Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Description:

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
Mitigation

Phase: Implementation

Description:

  • If possible, ensure that all external commands called from the program are statically created.
Mitigation ID: MIT-5

Phase: Implementation

Strategy: Input Validation

Description:

  • Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
  • When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
  • Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
Mitigation

Phase: Operation

Description:

  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
Mitigation

Phase: System Configuration

Description:

  • Assign permissions that prevent the user from accessing/opening privileged files.
CAPEC-136: LDAP Injection

An attacker manipulates or crafts an LDAP query for the purpose of undermining the security of the target. Some applications use user input to create LDAP queries that are processed by an LDAP server. For example, a user might provide their username during authentication and the username might be inserted in an LDAP query during the authentication process. An attacker could use this input to inject additional commands into an LDAP query that could disclose sensitive information. For example, entering a * in the aforementioned query might return information about all users on the system. This attack is very similar to an SQL injection attack in that it manipulates a query to gather additional information or coerce a particular return value.

CAPEC-15: Command Delimiters

An attack of this type exploits a programs' vulnerabilities that allows an attacker's commands to be concatenated onto a legitimate command with the intent of targeting other resources such as the file system or database. The system that uses a filter or denylist input validation, as opposed to allowlist validation is vulnerable to an attacker who predicts delimiters (or combinations of delimiters) not present in the filter or denylist. As with other injection attacks, the attacker uses the command delimiter payload as an entry point to tunnel through the application and activate additional attacks through SQL queries, shell commands, network scanning, and so on.

CAPEC-183: IMAP/SMTP Command Injection

An adversary exploits weaknesses in input validation on web-mail servers to execute commands on the IMAP/SMTP server. Web-mail servers often sit between the Internet and the IMAP or SMTP mail server. User requests are received by the web-mail servers which then query the back-end mail server for the requested information and return this response to the user. In an IMAP/SMTP command injection attack, mail-server commands are embedded in parts of the request sent to the web-mail server. If the web-mail server fails to adequately sanitize these requests, these commands are then sent to the back-end mail server when it is queried by the web-mail server, where the commands are then executed. This attack can be especially dangerous since administrators may assume that the back-end server is protected against direct Internet access and therefore may not secure it adequately against the execution of malicious commands.

CAPEC-248: Command Injection

An adversary looking to execute a command of their choosing, injects new items into an existing command thus modifying interpretation away from what was intended. Commands in this context are often standalone strings that are interpreted by a downstream component and cause specific responses. This type of attack is possible when untrusted values are used to build these command strings. Weaknesses in input validation or command construction can enable the attack and lead to successful exploitation.

CAPEC-40: Manipulating Writeable Terminal Devices

This attack exploits terminal devices that allow themselves to be written to by other users. The attacker sends command strings to the target terminal device hoping that the target user will hit enter and thereby execute the malicious command with their privileges. The attacker can send the results (such as copying /etc/passwd) to a known directory and collect once the attack has succeeded.

CAPEC-43: Exploiting Multiple Input Interpretation Layers

An attacker supplies the target software with input data that contains sequences of special characters designed to bypass input validation logic. This exploit relies on the target making multiples passes over the input data and processing a "layer" of special characters with each pass. In this manner, the attacker can disguise input that would otherwise be rejected as invalid by concealing it with layers of special/escape characters that are stripped off by subsequent processing steps. The goal is to first discover cases where the input validation layer executes before one or more parsing layers. That is, user input may go through the following logic in an application: <parser1> --> <input validator> --> <parser2>. In such cases, the attacker will need to provide input that will pass through the input validator, but after passing through parser2, will be converted into something that the input validator was supposed to stop.

CAPEC-75: Manipulating Writeable Configuration Files

Generally these are manually edited files that are not in the preview of the system administrators, any ability on the attackers' behalf to modify these files, for example in a CVS repository, gives unauthorized access directly to the application, the same as authorized users.

CAPEC-76: Manipulating Web Input to File System Calls

An attacker manipulates inputs to the target software which the target software passes to file system calls in the OS. The goal is to gain access to, and perhaps modify, areas of the file system that the target software did not intend to be accessible.

Back to CWE stats page