  <entry>
    <id>https://vulnerability.circl.lu/vuln/cve-2026-3611</id>
    <title>CVE-2026-3611 — Honeywell IQ4x BMS Controller Missing authentication for critical function</title>
    <updated>2026-09-29T22:33:42.605069+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> Honeywell IQ4E, Honeywell IQ412, Honeywell IQ422, Honeywell IQ4NC, Honeywell IQ41x, Honeywell IQ3, Honeywell IQECO</p>
<p>The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.</p></div>
    </content>
    <link href="https://vulnerability.circl.lu/vuln/cve-2026-3611"/>
  </entry>
  <entry>
    <id>https://vulnerability.circl.lu/vuln/icsa-26-069-03</id>
    <title>ICSA-26-069-03 — Honeywell IQ4x BMS Controller</title>
    <updated>2026-09-29T22:33:42.605199+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.</p>
      </div>
    </content>
    <link href="https://vulnerability.circl.lu/vuln/icsa-26-069-03"/>
  </entry>