  <entry>
    <id>https://vulnerability.circl.lu/vuln/cve-2025-40002</id>
    <title>CVE-2025-40002 — thunderbolt: Fix use-after-free in tb_dp_dprx_work</title>
    <updated>2026-09-28T23:54:56.842980+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> Linux</p>
<p>In the Linux kernel, the following vulnerability has been resolved:</p>
<p>thunderbolt: Fix use-after-free in tb_dp_dprx_work</p>
<p>The original code relies on cancel_delayed_work() in tb_dp_dprx_stop(),
which does not ensure that the delayed work item tunnel-&gt;dprx_work has
fully completed if it was already running. This leads to use-after-free
scenarios where tb_tunnel is deallocated by tb_tunnel_put(), while
tunnel-&gt;dprx_work remains active and attempts to dereference tb_tunnel
in tb_dp_dprx_work().</p>
<p>A typical race condition is illustrated below:</p>
<p>CPU 0                            | CPU 1
tb_dp_tunnel_active()            |
  tb_deactivate_and_free_tunnel()| tb_dp_dprx_start()
    tb_tunnel_deactivate()       |   queue_delayed_work()
      tb_dp_activate()           |
        tb_dp_dprx_stop()        | tb_dp_dprx_work() //delayed worker
          cancel_delayed_work()  |
    tb_tunnel_put(tunnel);       |
                                 |   tunnel = container_of(...); //UAF
                                 |   tunnel-&gt; //UAF</p>
<p>Replacing cancel_delayed_work() with cancel_delayed_work_sync() is
not feasible as it would introduce a deadlock: both tb_dp_dprx_work()
and the cleanup path acquire tb-&gt;lock, and cancel_delayed_work_sync()
would wait indefinitely for the work item that cannot proceed.</p>
<p>Instead, implement proper reference counting:
- If cancel_delayed_work() returns true (work is pending), we release
  the reference in the stop function.
- If it returns false (work is executing o…</p></div>