    <id>https://vulnerability.circl.lu/vuln/cve-2026-87672</id>
    <title>CVE-2026-87672</title>
    <updated>2026-10-10T08:09:19.977165+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> Brocade Fabric OS</p>
<p>An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.</p></div>