<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://vulnerability.circl.lu</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sun, 04 Oct 2026 23:36:23 +0000</lastBuildDate>
    <item>
      <title>CVE-2026-64502 — iio: adc: ad_sigma_delta: fix clear_pending_event for registerless devices</title>
      <link>https://vulnerability.circl.lu/vuln/cve-2026-64502</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Linux&lt;/p&gt;
&lt;p&gt;In the Linux kernel, the following vulnerability has been resolved:&lt;/p&gt;
&lt;p&gt;iio: adc: ad_sigma_delta: fix clear_pending_event for registerless devices&lt;/p&gt;
&lt;p&gt;ad_sigma_delta_clear_pending_event() falls through to the status register
read path for devices with has_registers = false and no rdy_gpiod. For
such devices, ad_sd_read_reg() skips the address byte entirely and clocks
raw MISO bytes with no address phase — making it byte-for-byte identical
to reading conversion data. If a pending conversion result is present,
this partially consumes it and corrupts the data stream for the subsequent
ad_sd_read_reg() call in ad_sigma_delta_single_conversion().&lt;/p&gt;
&lt;p&gt;Furthermore, with num_resetclks = 0 on these devices, data_read_len
evaluates to 0. If the clocked byte has bit 7 clear, pending_event is set
and the code attempts memset(data + 2, 0xff, 0 - 1), overflowing to
SIZE_MAX and corrupting the heap.&lt;/p&gt;
&lt;p&gt;Fix by returning 0 immediately when neither rdy_gpiod nor has_registers
is set. This is safe for all current registerless devices: ad7191 and
ad7780 (with powerdown GPIO) are reset between conversions by CS
deassertion, so there is no stale result to drain; ad7780 (without
powerdown GPIO) and max11205 are continuously-converting and cycle ~DRDY
at the output data rate regardless of whether the previous result was
read, so the next falling edge fires naturally.&lt;/p&gt;
&lt;p&gt;A future registerless device that holds ~DRDY asserted until data is read
would be broken by this early return and would require either
num_res…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Linux&lt;/p&gt;
&lt;p&gt;In the Linux kernel, the following vulnerability has been resolved:&lt;/p&gt;
&lt;p&gt;iio: adc: ad_sigma_delta: fix clear_pending_event for registerless devices&lt;/p&gt;
&lt;p&gt;ad_sigma_delta_clear_pending_event() falls through to the status register
read path for devices with has_registers = false and no rdy_gpiod. For
such devices, ad_sd_read_reg() skips the address byte entirely and clocks
raw MISO bytes with no address phase — making it byte-for-byte identical
to reading conversion data. If a pending conversion result is present,
this partially consumes it and corrupts the data stream for the subsequent
ad_sd_read_reg() call in ad_sigma_delta_single_conversion().&lt;/p&gt;
&lt;p&gt;Furthermore, with num_resetclks = 0 on these devices, data_read_len
evaluates to 0. If the clocked byte has bit 7 clear, pending_event is set
and the code attempts memset(data + 2, 0xff, 0 - 1), overflowing to
SIZE_MAX and corrupting the heap.&lt;/p&gt;
&lt;p&gt;Fix by returning 0 immediately when neither rdy_gpiod nor has_registers
is set. This is safe for all current registerless devices: ad7191 and
ad7780 (with powerdown GPIO) are reset between conversions by CS
deassertion, so there is no stale result to drain; ad7780 (without
powerdown GPIO) and max11205 are continuously-converting and cycle ~DRDY
at the output data rate regardless of whether the previous result was
read, so the next falling edge fires naturally.&lt;/p&gt;
&lt;p&gt;A future registerless device that holds ~DRDY asserted until data is read
would be broken by this early return and would require either
num_res…&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://vulnerability.circl.lu/vuln/cve-2026-64502</guid>