      <title>CVE-2026-74413 — wifi: rtw89: fix wrong pci_get_drvdata type in AER handlers</title>
      <link>https://vulnerability.circl.lu/vuln/cve-2026-74413</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Linux&lt;/p&gt;
&lt;p&gt;In the Linux kernel, the following vulnerability has been resolved:&lt;/p&gt;
&lt;p&gt;wifi: rtw89: fix wrong pci_get_drvdata type in AER handlers&lt;/p&gt;
&lt;p&gt;rtw89 stores an ieee80211_hw pointer via pci_set_drvdata() at probe
time, but io_error_detected() and io_resume() retrieve it as a
net_device pointer.  This causes netif_device_detach/attach to
operate on an ieee80211_hw struct, reading and writing at wrong
offsets.  The adjacent io_slot_reset() already does it correctly.&lt;/p&gt;
&lt;p&gt;Use ieee80211_stop_queues/wake_queues instead, consistent with
every other queue stop/start path in the driver.&lt;/p&gt;
&lt;p&gt;Tested on RTL8852CE by calling the handlers from a test module
before and after the fix.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Linux&lt;/p&gt;
&lt;p&gt;In the Linux kernel, the following vulnerability has been resolved:&lt;/p&gt;
&lt;p&gt;wifi: rtw89: fix wrong pci_get_drvdata type in AER handlers&lt;/p&gt;
&lt;p&gt;rtw89 stores an ieee80211_hw pointer via pci_set_drvdata() at probe
time, but io_error_detected() and io_resume() retrieve it as a
net_device pointer.  This causes netif_device_detach/attach to
operate on an ieee80211_hw struct, reading and writing at wrong
offsets.  The adjacent io_slot_reset() already does it correctly.&lt;/p&gt;
&lt;p&gt;Use ieee80211_stop_queues/wake_queues instead, consistent with
every other queue stop/start path in the driver.&lt;/p&gt;
&lt;p&gt;Tested on RTL8852CE by calling the handlers from a test module
before and after the fix.&lt;/p&gt;</content:encoded>