All the vulnerabilites related to Mitsubishi Electric Corporation - Mitsubishi Electric CNC C80 Series C80
cve-2024-7316
Vulnerability from cvelistv5
Published
2024-10-17 21:52
Modified
2024-10-18 20:09
Severity ?
EPSS score ?
Summary
Denial of Service (DoS) Vulnerability in Mitsubishi Electric CNC Series
References
▼ | URL | Tags |
---|---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-007_en.pdf | vendor-advisory | |
https://jvn.jp/vu/JVNVU92054409/index.html | government-resource | |
https://www.cisa.gov/news-events/ics-advisories/icsa-24-291-03 | government-resource |
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-7316", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-18T20:09:24.254479Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-18T20:09:37.573Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M800V Series M800VW", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2051W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M800V Series M800VS", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2052W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M80V Series M80V", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2053W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M80V Series M80VW", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2054W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M800 Series M800W", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2005W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M800 Series M800S", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2006W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M80 Series M80", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2007W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M80 Series M80W", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2008W000all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC E80 Series E80", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2009W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC C80 Series C80", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-2036W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M700V Series M720VW", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1015W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M700V Series M730VW", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1015W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M700V Series M750VW", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1015W002 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M700V Series M720VS", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1012W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M700V Series M730VS", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1012W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M700V Series M750VS", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1012W002 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC M70V Series M70V", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1018W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC E70 Series E70", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1022W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC Software Tools NC Trainer2", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1802W000 all versions" } ] }, { "defaultStatus": "unaffected", "product": "Mitsubishi Electric CNC Software Tools NC Trainer2 plus", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "System Number BND-1803W000 all versions" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric CNC Series allows a remote unauthenticated attacker to cause Denial of Service (DoS) condition on the product by sending specially crafted packets to TCP port 683, causing an emergency stop." } ], "value": "Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric CNC Series allows a remote unauthenticated attacker to cause Denial of Service (DoS) condition on the product by sending specially crafted packets to TCP port 683, causing an emergency stop." } ], "impacts": [ { "descriptions": [ { "lang": "en", "value": "Denial of Service (DoS)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1284", "description": "CWE-1284 Improper Validation of Specified Quantity in Input", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-17T21:52:22.864Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-007_en.pdf" }, { "tags": [ "government-resource" ], "url": "https://jvn.jp/vu/JVNVU92054409/index.html" }, { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-291-03" } ], "source": { "discovery": "UNKNOWN" }, "title": "Denial of Service (DoS) Vulnerability in Mitsubishi Electric CNC Series", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2024-7316", "datePublished": "2024-10-17T21:52:22.864Z", "dateReserved": "2024-07-30T22:11:46.399Z", "dateUpdated": "2024-10-18T20:09:37.573Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }