3 vulnerabilities found for guardian_link_2_transmitter_mmt-7775_firmware by medtronic

FKIE_CVE-2022-32537

Vulnerability from fkie_nvd - Published: 2022-12-12 13:15 - Updated: 2024-11-21 07:06
Summary
A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance
Impacted products
Vendor Product Version
medtronic guardian_link_2_transmitter_mmt-7730_firmware -
medtronic guardian_link_2_transmitter_mmt-7730 -
medtronic guardian_link_2_transmitter_mmt-7731_firmware -
medtronic guardian_link_2_transmitter_mmt-7731 -
medtronic guardian_link_2_transmitter_mmt-7738_firmware -
medtronic guardian_link_2_transmitter_mmt-7738 -
medtronic guardian_link_2_transmitter_mmt-7775_firmware -
medtronic guardian_link_2_transmitter_mmt-7775 -
medtronic guardian_link_3_transmitter_mmt-7810_firmware -
medtronic guardian_link_3_transmitter_mmt-7810 -
medtronic guardian_link_3_transmitter_mmt-7811_firmware -
medtronic guardian_link_3_transmitter_mmt-7811 -
medtronic minimed_620g_mmt-1750_firmware -
medtronic minimed_620g_mmt-1750 -
medtronic minimed_630g_mmt-1715_firmware -
medtronic minimed_630g_mmt-1715 -
medtronic minimed_630g_mmt-1754_firmware -
medtronic minimed_630g_mmt-1754 -
medtronic minimed_630g_mmt-1755_firmware -
medtronic minimed_630g_mmt-1755 -
medtronic minimed_640g_mmt-1711_firmware -
medtronic minimed_640g_mmt-1711 -
medtronic minimed_640g_mmt-1712_firmware -
medtronic minimed_640g_mmt-1712 -
medtronic minimed_640g_mmt-1751_firmware -
medtronic minimed_640g_mmt-1751 -
medtronic minimed_640g_mmt-1752_firmware -
medtronic minimed_640g_mmt-1752 -
medtronic minimed_670g_mmt-1740_firmware -
medtronic minimed_670g_mmt-1740 -
medtronic minimed_670g_mmt-1741_firmware -
medtronic minimed_670g_mmt-1741 -
medtronic minimed_670g_mmt-1742_firmware -
medtronic minimed_670g_mmt-1742 -
medtronic minimed_670g_mmt-1760_firmware -
medtronic minimed_670g_mmt-1760 -
medtronic minimed_670g_mmt-1761_firmware -
medtronic minimed_670g_mmt-1761 -
medtronic minimed_670g_mmt-1762_firmware -
medtronic minimed_670g_mmt-1762 -
medtronic minimed_670g_mmt-1780_firmware -
medtronic minimed_670g_mmt-1780 -
medtronic minimed_670g_mmt-1781_firmware -
medtronic minimed_670g_mmt-1781 -
medtronic minimed_670g_mmt-1782_firmware -
medtronic minimed_670g_mmt-1782 -
medtronic mmt-1151_firmware -
medtronic mmt-1151 -
medtronic mmt-1152_firmware -
medtronic mmt-1152 -
medtronic mmt-1351_firmware -
medtronic mmt-1351 -
medtronic mmt-1352_firmware -
medtronic mmt-1352 -
medtronic mmt-7306_firmware -
medtronic mmt-7306 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7730_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C5AA07C-EB49-4DB1-91C5-5B7FF9BC60DE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:guardian_link_2_transmitter_mmt-7730:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "615FEF55-7051-4CE2-9D10-2D8643C8E599",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7731_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1E499AF-6392-4D48-A2AA-6DF89B725CF5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:guardian_link_2_transmitter_mmt-7731:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "60CD7CC1-83A0-4890-9C3D-80CFC435469A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7738_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D61D148-8A08-402B-8252-A0C7E2C1606D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:guardian_link_2_transmitter_mmt-7738:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A183442-FB5F-4BD0-A390-05E1D2BB9B9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7775_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53B3B95A-1706-45A3-A70E-1B598F7E6E24",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:guardian_link_2_transmitter_mmt-7775:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CB928B7-ABD2-40A7-9CBE-DA77A2FB3FC6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:guardian_link_3_transmitter_mmt-7810_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "795ADE03-3C93-48DB-B0C0-9D732A56619A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:guardian_link_3_transmitter_mmt-7810:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "209B1C70-6ABE-4AAE-B413-36BCED848C1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:guardian_link_3_transmitter_mmt-7811_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "827E4A1F-E3A7-4BC1-8671-2E29A9690885",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:guardian_link_3_transmitter_mmt-7811:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A710ACB1-FB33-4410-ACB5-628BEF78B2DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_620g_mmt-1750_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "52100FBF-B15B-4C23-AF3E-D5B08A20138C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_620g_mmt-1750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C6E5125-613D-4318-8894-A0EA7E70A23A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_630g_mmt-1715_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7A62CB9-0CB5-4E69-865B-6DCCC5E52623",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_630g_mmt-1715:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "71B6DDBD-7710-48F0-AE17-666B0ABD85C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_630g_mmt-1754_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD1DAC2D-E81E-4A9F-8EC3-475B68D08E4D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_630g_mmt-1754:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3AD50208-75AD-4201-B50B-9B3C2B92D4B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_630g_mmt-1755_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E7195EE-CFDC-4592-A40C-E4C809B3A299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_630g_mmt-1755:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFB1067F-85DD-4AC3-9A2D-96AF7487A169",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_640g_mmt-1711_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DE3A51F-C0B9-4FE8-937F-3D0A65447B86",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_640g_mmt-1711:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D08E98-E921-48B6-860F-941AEAE6A1C6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_640g_mmt-1712_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D58A6AA9-E899-4EB0-B43A-5B55142037C9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_640g_mmt-1712:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "45D90195-01D6-40BC-B4CF-36FA555D1EC2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_640g_mmt-1751_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB9F223A-63E6-4A62-B7D1-BA58547E8611",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_640g_mmt-1751:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "256F9F01-2109-4857-ABE5-3EA1284F8D93",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_640g_mmt-1752_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF1C533C-43A1-407D-88DF-C9467D2B63E8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_640g_mmt-1752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6685F923-556D-4274-99B4-6DB7A2FC75B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1740_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "22187A09-60DA-4359-B310-F9C982795EEF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1740:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0000AE0-FD3F-4CC8-B00D-A1C58EE1BB1B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1741_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F8B6AAF-5043-48B7-A638-98F3624202ED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1741:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12584AA5-E57C-473A-8E1F-4398ADADFCD7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1742_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5AEA1F9-2259-44F7-B175-0C26ECDF228A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1742:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49C86FAB-7C0D-4F81-9CA2-2AF809760029",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1760_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF1A796D-25D0-4640-BF69-DE2886608F9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1760:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F110C3E4-808E-4DF0-9952-E3C38EA36D66",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1761_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4235875-59AE-42FB-B66C-03EDE76B12F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1761:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A78FB8FF-C0C1-4678-B686-295ED7040659",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1762_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7BC3BEE-987F-4B65-9FE3-604FCB2487BC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1762:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B931BE-24E0-4D5F-866D-E715E4673474",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1780_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "665944D0-B221-4BC3-BE1B-0A6F77B4BCF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1780:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9123F954-4788-417D-B06C-3EA8F9C08165",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1781_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "52C27006-E33E-4025-B20A-60A2D9DB451B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1781:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "48985412-63A5-4296-9EBD-7FBE617E5FC1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:minimed_670g_mmt-1782_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0BB979C-5A06-4975-83B7-D92A29E1FC03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:minimed_670g_mmt-1782:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EEE3ED1A-6C7D-4D7F-A650-E905C8E92C2C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:mmt-1151_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9700FDA5-541C-48FF-A0FE-5B14B6B8A60A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:mmt-1151:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3056ECAE-8567-4704-ABEB-F07E2E16D50A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:mmt-1152_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B8B0E02-BA08-4EBF-9D71-AD1B35252E5F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:mmt-1152:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5037978F-0204-4304-83BC-4201CCDCEB5C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:mmt-1351_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB0E24E7-9E50-4BA3-9F8A-4B44F84BF765",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:mmt-1351:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08AC3AC-ED38-43FA-932E-93821076040D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:mmt-1352_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B54B7156-1903-4274-9743-9D69DF1D52D6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:mmt-1352:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08D75197-E41F-47BD-8079-38DB5659CF21",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:medtronic:mmt-7306_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0967A9CC-66FF-4C20-80BA-BEA5945EB793",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:medtronic:mmt-7306:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F3D5290-AC9A-4687-B634-CFF21FEB84FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance\n"
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad que podr\u00eda permitir que un usuario no autorizado conozca aspectos del protocolo de comunicaci\u00f3n utilizado para emparejar componentes del sistema mientras la bomba se empareja con otros componentes del sistema. La explotaci\u00f3n requiere proximidad de se\u00f1al inal\u00e1mbrica cercana con el paciente y el dispositivo; Se requieren conocimientos t\u00e9cnicos avanzados para su explotaci\u00f3n. Consulte el Bolet\u00edn de seguridad de productos de Medtronic para obtener orientaci\u00f3n."
    }
  ],
  "id": "CVE-2022-32537",
  "lastModified": "2024-11-21T07:06:35.333",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.6,
        "source": "security@medtronic.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-12-12T13:15:12.263",
  "references": [
    {
      "source": "security@medtronic.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.html"
    },
    {
      "source": "security@medtronic.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-263-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-263-01"
    }
  ],
  "sourceIdentifier": "security@medtronic.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-693"
        }
      ],
      "source": "security@medtronic.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2022-32537 (GCVE-0-2022-32537)

Vulnerability from cvelistv5 – Published: 2022-11-17 20:47 – Updated: 2025-04-29 14:44
VLAI?
Summary
A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance
CWE
Assigner
Impacted products
Vendor Product Version
Medtronic Minimed 600 Series Insulin Pump Affected: 620G, 630G, 640G, 670G
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:46:43.499Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-263-01"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-32537",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T14:44:04.441292Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T14:44:21.348Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Minimed 600 Series Insulin Pump",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "620G, 630G, 640G, 670G"
            }
          ]
        }
      ],
      "datePublic": "2022-09-20T19:31:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-693",
              "description": "CWE-693",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-12T12:51:56.582Z",
        "orgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
        "shortName": "Medtronic"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-263-01"
        },
        {
          "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Medtronic MiniMed 600 Series Pump System Communication Issue",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
    "assignerShortName": "Medtronic",
    "cveId": "CVE-2022-32537",
    "datePublished": "2022-11-17T20:47:05.258Z",
    "dateReserved": "2022-06-07T21:26:39.432Z",
    "dateUpdated": "2025-04-29T14:44:21.348Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-32537 (GCVE-0-2022-32537)

Vulnerability from nvd – Published: 2022-11-17 20:47 – Updated: 2025-04-29 14:44
VLAI?
Summary
A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance
CWE
Assigner
Impacted products
Vendor Product Version
Medtronic Minimed 600 Series Insulin Pump Affected: 620G, 630G, 640G, 670G
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:46:43.499Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-263-01"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-32537",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T14:44:04.441292Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T14:44:21.348Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Minimed 600 Series Insulin Pump",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "620G, 630G, 640G, 670G"
            }
          ]
        }
      ],
      "datePublic": "2022-09-20T19:31:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-693",
              "description": "CWE-693",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-12T12:51:56.582Z",
        "orgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
        "shortName": "Medtronic"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-263-01"
        },
        {
          "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Medtronic MiniMed 600 Series Pump System Communication Issue",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
    "assignerShortName": "Medtronic",
    "cveId": "CVE-2022-32537",
    "datePublished": "2022-11-17T20:47:05.258Z",
    "dateReserved": "2022-06-07T21:26:39.432Z",
    "dateUpdated": "2025-04-29T14:44:21.348Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}