Search criteria
9 vulnerabilities found for n300rh-v3_firmware by totolink
FKIE_CVE-2020-25499
Vulnerability from fkie_nvd - Published: 2020-12-09 21:15 - Updated: 2024-11-21 05:18
Severity ?
Summary
TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system's 'Run Command'. An attacker can use this functionality to execute arbitrary OS commands on the router.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2 | Exploit, Third Party Advisory | |
| cve@mitre.org | https://www.totolink.net/home/index/newsss/id/196.html | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.totolink.net/home/index/newsss/id/196.html | Patch, Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:a3002r_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E5AA5F65-A666-4A60-91D7-EABF708170EB",
"versionEndExcluding": "1.1.1-b20200824.0128",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:a3002r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2CBBBC48-8918-4D59-8059-285404AE7716",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:a3002ru-v1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4E0F90C0-EC26-4F57-8624-0EB1057302D3",
"versionEndExcluding": "3.4.0-b20201030.1754",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:a3002ru-v1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5CD41BE-CDB7-4837-82D1-6C0B66037CD3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:a3002ru-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4C4A5C22-01E2-429D-867C-9351822F20E6",
"versionEndExcluding": "2.1.1-b20200911.1756",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:a3002ru-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "720DB583-0A2B-4538-88A4-F90D32FC67EE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:a702r-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56024E88-14F8-485D-B222-0DBFBF8AEBBE",
"versionEndExcluding": "1.0.0-b20201028.1743",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:a702r-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4793791A-832B-4CE9-904A-CD2C42A1B2CC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:a702r-v3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E956F23E-F4F0-42FE-B53A-62F13E6EA7DD",
"versionEndExcluding": "1.0.0-b20201103.1713",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:a702r-v3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4402B575-14BC-441C-BF49-A5E0275650D8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n100re-v3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C533E019-DF7C-4AF1-8530-03E879AE49BD",
"versionEndExcluding": "3.4.0-b20201030.0926",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n100re-v3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3EAEB0A7-37C9-418C-9658-FA321594F9BB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n150rt_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43BF4C58-31C2-4AE7-8858-2C5C4BED4A74",
"versionEndExcluding": "3.4.0-b20201030.1142",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n150rt:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7525BE05-F394-4ED7-B7A6-F9005EDE90D7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n200re-v3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8E2C8202-4F82-4A74-9919-0E8C4A97A113",
"versionEndExcluding": "3.4.0-b20201029.1811",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n200re-v3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0BA1AA4B-5CFA-4200-B132-75D8B8981396",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n200re-v4_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2E9DDDBB-F4C0-417E-BB39-2324D4A25EEC",
"versionEndExcluding": "4.0.0-b20200805.1507",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n200re-v4:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4BFDB792-2EB3-4045-A5A8-A57B72B8368E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n210re_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56450DF0-5C38-4D19-9E50-222BBB1C0329",
"versionEndExcluding": "1.0.0-b20201030.2030",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n210re:-:*:*:*:*:*:*:*",
"matchCriteriaId": "93445A4F-C8AA-4A55-80A7-41CAAB588A99",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n300rh-v3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5F391AC8-AEF5-4E97-97AC-58ECFCFDD626",
"versionEndExcluding": "3.2.4-b20201029.1838",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n300rh-v3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "058F675A-3C67-4B73-808C-8C65D7D65C12",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n300rt_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C6A01759-06EE-40F0-AE11-8FFFAB3074F6",
"versionEndExcluding": "3.4.0-b20201026.2033",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n300rt:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0581174-E6B1-4E3D-8384-7852EC53FC14",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n302r_plus_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E2DCBB0C-FEB1-45B4-BA07-F73F08BCBE47",
"versionEndExcluding": "3.4.0-b20201028.2224",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n302r_plus:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C06D3FD9-582D-4E26-9928-DF3609EF3373",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system\u0027s \u0027Run Command\u0027. An attacker can use this functionality to execute arbitrary OS commands on the router."
},
{
"lang": "es",
"value": "TOTOLINK A3002RU-V2.0.0 versi\u00f3n B20190814.1034, permite a usuarios remotos autenticados modificar el \"Run Command\" del sistema.\u0026#xa0;Un atacante puede usar esta funcionalidad para ejecutar comandos arbitrarios del sistema operativo en el enrutador"
}
],
"id": "CVE-2020-25499",
"lastModified": "2024-11-21T05:18:04.130",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-12-09T21:15:15.477",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
},
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.totolink.net/home/index/newsss/id/196.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.totolink.net/home/index/newsss/id/196.html"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
},
{
"lang": "en",
"value": "CWE-862"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2015-9551
Vulnerability from fkie_nvd - Published: 2020-11-24 21:15 - Updated: 2024-11-21 02:40
Severity ?
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| totolink | a850r-v1_firmware | * | |
| totolink | a850r-v1 | - | |
| totolink | f1-v2_firmware | * | |
| totolink | f1-v2 | - | |
| totolink | f2-v1_firmware | * | |
| totolink | f2-v1 | - | |
| totolink | n150rt-v2_firmware | * | |
| totolink | n150rt-v2 | - | |
| totolink | n151rt-v2_firmware | * | |
| totolink | n151rt-v2 | - | |
| totolink | n300rh-v2_firmware | * | |
| totolink | n300rh-v2 | - | |
| totolink | n300rh-v3_firmware | * | |
| totolink | n300rh-v3 | - | |
| totolink | n300rt-v2_firmware | * | |
| totolink | n300rt-v2 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:a850r-v1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "29DDFAFC-3538-45B5-AB36-3895F16BD764",
"versionEndExcluding": "1.0.1-b20150707.1612",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:a850r-v1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "74953383-D90B-4B54-B02B-617BCF8010E9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:f1-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FBC80064-797F-487C-99C1-D8F4981D4990",
"versionEndExcluding": "2.1.1-b20150708.1646",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:f1-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "611785C4-C11E-4F73-BB8B-DFEE66F3FB6A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:f2-v1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6844CA14-C66E-4E6B-ABC6-1D083EEF9D82",
"versionEndExcluding": "2.1.0-b20150320.1611",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:f2-v1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B693CF6C-A0C7-42DD-AA82-36887087BCED",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n150rt-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "572842ED-48C4-4D90-B107-EF6DBFC19585",
"versionEndExcluding": "2.1.1-b20150708.1548",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n150rt-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0251C2F8-9BCC-4B34-8747-09CA39E6CE7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n151rt-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F7E9FE34-8EBD-47BD-AD90-F07381E0C06A",
"versionEndExcluding": "1.1-b20150708.1559",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n151rt-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "00922E42-2177-4214-8A1E-8FEB6BDE2869",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n300rh-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1D436BD3-1C39-49CE-BC15-50C890F58931",
"versionEndExcluding": "2.0.1-b20150708.1625",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n300rh-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B0ECED9E-930D-4061-ABB4-CC2DD2346BBC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n300rh-v3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3BC6C344-01DD-4EB6-B1A3-60B782E81BA4",
"versionEndExcluding": "3.0.0-b20150331.0858",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n300rh-v3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "058F675A-3C67-4B73-808C-8C65D7D65C12",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n300rt-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74971352-B072-4A9A-B07E-4E92F35C716A",
"versionEndExcluding": "2.1.1-b20150708.1613",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n300rt-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4637323A-10A8-4841-BC49-3EF2894C5F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos TOTOLINK A850R-V1 versiones hasta 1.0.1-B20150707.1612 y F1-V2 versiones hasta 1.1-B20150708.1646.\u0026#xa0;Se presenta una Ejecuci\u00f3n de C\u00f3digo Remota en la interfaz de administraci\u00f3n por medio del par\u00e1metro formSysCmd sysCmd"
}
],
"id": "CVE-2015-9551",
"lastModified": "2024-11-21T02:40:54.613",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-24T21:15:11.417",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2015-9550
Vulnerability from fkie_nvd - Published: 2020-11-24 21:15 - Updated: 2024-11-21 02:40
Severity ?
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| totolink | a850r-v1_firmware | * | |
| totolink | a850r-v1 | - | |
| totolink | f1-v2_firmware | * | |
| totolink | f1-v2 | - | |
| totolink | f2-v1_firmware | * | |
| totolink | f2-v1 | - | |
| totolink | n150rt-v2_firmware | * | |
| totolink | n150rt-v2 | - | |
| totolink | n151rt-v2_firmware | * | |
| totolink | n151rt-v2 | - | |
| totolink | n300rh-v2_firmware | * | |
| totolink | n300rh-v2 | - | |
| totolink | n300rh-v3_firmware | * | |
| totolink | n300rh-v3 | - | |
| totolink | n300rt-v2_firmware | * | |
| totolink | n300rt-v2 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:a850r-v1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "29DDFAFC-3538-45B5-AB36-3895F16BD764",
"versionEndExcluding": "1.0.1-b20150707.1612",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:a850r-v1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "74953383-D90B-4B54-B02B-617BCF8010E9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:f1-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FBC80064-797F-487C-99C1-D8F4981D4990",
"versionEndExcluding": "2.1.1-b20150708.1646",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:f1-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "611785C4-C11E-4F73-BB8B-DFEE66F3FB6A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:f2-v1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6844CA14-C66E-4E6B-ABC6-1D083EEF9D82",
"versionEndExcluding": "2.1.0-b20150320.1611",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:f2-v1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B693CF6C-A0C7-42DD-AA82-36887087BCED",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n150rt-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "572842ED-48C4-4D90-B107-EF6DBFC19585",
"versionEndExcluding": "2.1.1-b20150708.1548",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n150rt-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0251C2F8-9BCC-4B34-8747-09CA39E6CE7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n151rt-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F7E9FE34-8EBD-47BD-AD90-F07381E0C06A",
"versionEndExcluding": "1.1-b20150708.1559",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n151rt-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "00922E42-2177-4214-8A1E-8FEB6BDE2869",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n300rh-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1D436BD3-1C39-49CE-BC15-50C890F58931",
"versionEndExcluding": "2.0.1-b20150708.1625",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n300rh-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B0ECED9E-930D-4061-ABB4-CC2DD2346BBC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n300rh-v3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3BC6C344-01DD-4EB6-B1A3-60B782E81BA4",
"versionEndExcluding": "3.0.0-b20150331.0858",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n300rh-v3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "058F675A-3C67-4B73-808C-8C65D7D65C12",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:n300rt-v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74971352-B072-4A9A-B07E-4E92F35C716A",
"versionEndExcluding": "2.1.1-b20150708.1613",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:n300rt-v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4637323A-10A8-4841-BC49-3EF2894C5F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en los dispositivos TOTOLINK A850R-V1 versiones hasta 1.0.1-B20150707.1612 y F1-V2 versiones hasta 1.1-B20150708.1646.\u0026#xa0;Mediante el env\u00edo de un paquete hel,xasf espec\u00edfico hacia la interfaz WAN, es posible abrir la interfaz de administraci\u00f3n web sobre la interfaz WAN"
}
],
"id": "CVE-2015-9550",
"lastModified": "2024-11-21T02:40:54.460",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-24T21:15:11.353",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-668"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-25499 (GCVE-0-2020-25499)
Vulnerability from cvelistv5 – Published: 2020-12-09 20:30 – Updated: 2024-08-04 15:33
VLAI?
Summary
TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system's 'Run Command'. An attacker can use this functionality to execute arbitrary OS commands on the router.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.689Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.totolink.net/home/index/newsss/id/196.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2020-10-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system\u0027s \u0027Run Command\u0027. An attacker can use this functionality to execute arbitrary OS commands on the router."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-09T20:30:55",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.totolink.net/home/index/newsss/id/196.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25499",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system\u0027s \u0027Run Command\u0027. An attacker can use this functionality to execute arbitrary OS commands on the router."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.totolink.net/home/index/newsss/id/196.html",
"refsource": "CONFIRM",
"url": "https://www.totolink.net/home/index/newsss/id/196.html"
},
{
"name": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2",
"refsource": "MISC",
"url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25499",
"datePublished": "2020-12-09T20:30:55",
"dateReserved": "2020-09-14T00:00:00",
"dateUpdated": "2024-08-04T15:33:05.689Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-9550 (GCVE-0-2015-9550)
Vulnerability from cvelistv5 – Published: 2020-11-24 21:01 – Updated: 2024-08-06 08:51
VLAI?
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T08:51:05.311Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-24T21:01:41",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-9550",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html",
"refsource": "MISC",
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-9550",
"datePublished": "2020-11-24T21:01:41",
"dateReserved": "2020-11-24T00:00:00",
"dateUpdated": "2024-08-06T08:51:05.311Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-9551 (GCVE-0-2015-9551)
Vulnerability from cvelistv5 – Published: 2020-11-24 21:01 – Updated: 2024-08-06 08:58
VLAI?
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T08:58:24.569Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-24T21:01:27",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-9551",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html",
"refsource": "MISC",
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-9551",
"datePublished": "2020-11-24T21:01:27",
"dateReserved": "2020-11-24T00:00:00",
"dateUpdated": "2024-08-06T08:58:24.569Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25499 (GCVE-0-2020-25499)
Vulnerability from nvd – Published: 2020-12-09 20:30 – Updated: 2024-08-04 15:33
VLAI?
Summary
TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system's 'Run Command'. An attacker can use this functionality to execute arbitrary OS commands on the router.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.689Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.totolink.net/home/index/newsss/id/196.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2020-10-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system\u0027s \u0027Run Command\u0027. An attacker can use this functionality to execute arbitrary OS commands on the router."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-09T20:30:55",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.totolink.net/home/index/newsss/id/196.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25499",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system\u0027s \u0027Run Command\u0027. An attacker can use this functionality to execute arbitrary OS commands on the router."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.totolink.net/home/index/newsss/id/196.html",
"refsource": "CONFIRM",
"url": "https://www.totolink.net/home/index/newsss/id/196.html"
},
{
"name": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2",
"refsource": "MISC",
"url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25499",
"datePublished": "2020-12-09T20:30:55",
"dateReserved": "2020-09-14T00:00:00",
"dateUpdated": "2024-08-04T15:33:05.689Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-9550 (GCVE-0-2015-9550)
Vulnerability from nvd – Published: 2020-11-24 21:01 – Updated: 2024-08-06 08:51
VLAI?
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T08:51:05.311Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-24T21:01:41",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-9550",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html",
"refsource": "MISC",
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-9550",
"datePublished": "2020-11-24T21:01:41",
"dateReserved": "2020-11-24T00:00:00",
"dateUpdated": "2024-08-06T08:51:05.311Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-9551 (GCVE-0-2015-9551)
Vulnerability from nvd – Published: 2020-11-24 21:01 – Updated: 2024-08-06 08:58
VLAI?
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T08:58:24.569Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-24T21:01:27",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-9551",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html",
"refsource": "MISC",
"url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-9551",
"datePublished": "2020-11-24T21:01:27",
"dateReserved": "2020-11-24T00:00:00",
"dateUpdated": "2024-08-06T08:58:24.569Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}