Search criteria
12 vulnerabilities found for wc7600_firmware by netgear
FKIE_CVE-2020-26931
Vulnerability from fkie_nvd - Published: 2020-10-09 07:15 - Updated: 2024-11-21 05:20
Severity ?
5.9 (Medium) - CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wc7500_firmware | * | |
| netgear | wc7500 | - | |
| netgear | wc7600_firmware | * | |
| netgear | wc7600 | - | |
| netgear | wc7600_firmware | * | |
| netgear | wc7600 | v2 | |
| netgear | wc9500_firmware | * | |
| netgear | wc9500 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C7EBAEB-4D71-4F10-8B42-F5C844E1B71E",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB22B065-8EC8-4DA7-984A-CCB6919AF8F3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93AD60DB-0EBB-467B-AD0C-5C107DCC446F",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF16A53E-FFFD-4F11-831A-82BB76675CBD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93AD60DB-0EBB-467B-AD0C-5C107DCC446F",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "10DD5BCE-4C6F-4524-94C0-9779E897BFB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23E6496E-07CD-4191-B117-530D063514EE",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "113D0DF6-C719-4A43-80B2-463EC4323009",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial.\u0026#xa0;Esto afecta a WC7500 versiones anteriores a 6.5.5.24, WC7600 versiones anteriores a 6.5.5.24, WC7600v2 versiones anteriores a 6.5.5.24 y WC9500 versiones anteriores a 6.5.5.24"
}
],
"id": "CVE-2020-26931",
"lastModified": "2024-11-21T05:20:31.537",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 4.2,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-10-09T07:15:18.653",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-26923
Vulnerability from fkie_nvd - Published: 2020-10-09 07:15 - Updated: 2024-11-21 05:20
Severity ?
4.3 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wc7500_firmware | * | |
| netgear | wc7500 | - | |
| netgear | wc7600_firmware | * | |
| netgear | wc7600 | - | |
| netgear | wc7600v2_firmware | * | |
| netgear | wc7600v2 | - | |
| netgear | wc9500_firmware | * | |
| netgear | wc9500 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C7EBAEB-4D71-4F10-8B42-F5C844E1B71E",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB22B065-8EC8-4DA7-984A-CCB6919AF8F3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93AD60DB-0EBB-467B-AD0C-5C107DCC446F",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF16A53E-FFFD-4F11-831A-82BB76675CBD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "470918A5-9FE0-4F63-8455-5527CF138F54",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C8BB1F1-A12D-43CC-A6D0-9633E99D746B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23E6496E-07CD-4191-B117-530D063514EE",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "113D0DF6-C719-4A43-80B2-463EC4323009",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado.\u0026#xa0;Esto afecta a WC7500 versiones anteriores a 6.5.5.24, WC7600 versiones anteriores a 6.5.5.24, WC7600v2 versiones anteriores a 6.5.5.24 y WC9500 versiones anteriores a 6.5.5.24"
}
],
"id": "CVE-2020-26923",
"lastModified": "2024-11-21T05:20:30.363",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 2.7,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-10-09T07:15:17.950",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-26922
Vulnerability from fkie_nvd - Published: 2020-10-09 07:15 - Updated: 2024-11-21 05:20
Severity ?
6.4 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wc7500_firmware | * | |
| netgear | wc7500 | - | |
| netgear | wc7600_firmware | * | |
| netgear | wc7600 | - | |
| netgear | wc7600v2_firmware | * | |
| netgear | wc7600v2 | - | |
| netgear | wc9500_firmware | * | |
| netgear | wc9500 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C7EBAEB-4D71-4F10-8B42-F5C844E1B71E",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB22B065-8EC8-4DA7-984A-CCB6919AF8F3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93AD60DB-0EBB-467B-AD0C-5C107DCC446F",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF16A53E-FFFD-4F11-831A-82BB76675CBD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "470918A5-9FE0-4F63-8455-5527CF138F54",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C8BB1F1-A12D-43CC-A6D0-9633E99D746B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23E6496E-07CD-4191-B117-530D063514EE",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "113D0DF6-C719-4A43-80B2-463EC4323009",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado.\u0026#xa0;Esto afecta a WC7500 versiones anteriores a 6.5.5.24, WC7600 versiones anteriores a 6.5.5.24, WC7600v2 versiones anteriores a 6.5.5.24 y WC9500 versiones anteriores a 6.5.5.24"
}
],
"id": "CVE-2020-26922",
"lastModified": "2024-11-21T05:20:30.220",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.5,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-10-09T07:15:17.857",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-21123
Vulnerability from fkie_nvd - Published: 2020-04-22 16:15 - Updated: 2024-11-21 04:02
Severity ?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wc7500_firmware | * | |
| netgear | wc7500 | - | |
| netgear | wc7520_firmware | * | |
| netgear | wc7520 | - | |
| netgear | wc7600_firmware | * | |
| netgear | wc7600 | v1 | |
| netgear | wc7600_firmware | * | |
| netgear | wc7600 | v2 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "457896CF-BF39-42F9-93B4-3B98B043D56A",
"versionEndExcluding": "6.5.3.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB22B065-8EC8-4DA7-984A-CCB6919AF8F3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7520_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C28CDB2B-9E25-40A5-AE57-39954BD8EC4F",
"versionEndExcluding": "6.5.3.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7520:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A58C9FE8-4BD5-41F9-9714-2D8083A51D98",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACC819C7-3CAE-4C52-96CD-B9F8E0DCD816",
"versionEndExcluding": "6.5.3.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600:v1:*:*:*:*:*:*:*",
"matchCriteriaId": "1DE67DAE-CB9A-497B-8B23-94E1DE93329B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACC819C7-3CAE-4C52-96CD-B9F8E0DCD816",
"versionEndExcluding": "6.5.3.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "10DD5BCE-4C6F-4524-94C0-9779E897BFB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a WC7500 versiones anteriores a 6.5.3.9, WC7520 versiones anteriores a 6.5.3.9, WC7600v1 versiones anteriores a 6.5.3.9 y WC7600v2 versiones anteriores a 6.5.3.9."
}
],
"id": "CVE-2018-21123",
"lastModified": "2024-11-21T04:02:57.413",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-22T16:15:12.420",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-74"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-26922 (GCVE-0-2020-26922)
Vulnerability from cvelistv5 – Published: 2020-10-09 06:28 – Updated: 2024-08-04 16:03
VLAI?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity ?
6.4 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:22.927Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:28:06",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26922",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26922",
"datePublished": "2020-10-09T06:28:06",
"dateReserved": "2020-10-09T00:00:00",
"dateUpdated": "2024-08-04T16:03:22.927Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26923 (GCVE-0-2020-26923)
Vulnerability from cvelistv5 – Published: 2020-10-09 06:27 – Updated: 2024-08-04 16:03
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity ?
4.3 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:22.835Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:27:48",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26923",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26923",
"datePublished": "2020-10-09T06:27:48",
"dateReserved": "2020-10-09T00:00:00",
"dateUpdated": "2024-08-04T16:03:22.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26931 (GCVE-0-2020-26931)
Vulnerability from cvelistv5 – Published: 2020-10-09 06:24 – Updated: 2024-08-04 16:03
VLAI?
Summary
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity ?
5.9 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:23.058Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:24:55",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26931",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26931",
"datePublished": "2020-10-09T06:24:55",
"dateReserved": "2020-10-09T00:00:00",
"dateUpdated": "2024-08-04T16:03:23.058Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21123 (GCVE-0-2018-21123)
Vulnerability from cvelistv5 – Published: 2020-04-22 15:48 – Updated: 2024-08-05 12:19
VLAI?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:19:27.638Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-09-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-22T15:48:06",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21123",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21123",
"datePublished": "2020-04-22T15:48:06",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T12:19:27.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26922 (GCVE-0-2020-26922)
Vulnerability from nvd – Published: 2020-10-09 06:28 – Updated: 2024-08-04 16:03
VLAI?
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity ?
6.4 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:22.927Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:28:06",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26922",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26922",
"datePublished": "2020-10-09T06:28:06",
"dateReserved": "2020-10-09T00:00:00",
"dateUpdated": "2024-08-04T16:03:22.927Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26923 (GCVE-0-2020-26923)
Vulnerability from nvd – Published: 2020-10-09 06:27 – Updated: 2024-08-04 16:03
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity ?
4.3 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:22.835Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:27:48",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26923",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26923",
"datePublished": "2020-10-09T06:27:48",
"dateReserved": "2020-10-09T00:00:00",
"dateUpdated": "2024-08-04T16:03:22.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26931 (GCVE-0-2020-26931)
Vulnerability from nvd – Published: 2020-10-09 06:24 – Updated: 2024-08-04 16:03
VLAI?
Summary
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity ?
5.9 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:23.058Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:24:55",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26931",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26931",
"datePublished": "2020-10-09T06:24:55",
"dateReserved": "2020-10-09T00:00:00",
"dateUpdated": "2024-08-04T16:03:23.058Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21123 (GCVE-0-2018-21123)
Vulnerability from nvd – Published: 2020-04-22 15:48 – Updated: 2024-08-05 12:19
VLAI?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:19:27.638Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-09-26T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-22T15:48:06",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21123",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21123",
"datePublished": "2020-04-22T15:48:06",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T12:19:27.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}