    CVE-2025-58319 (GCVE-0-2025-58319)

    Vulnerability from nvd – Published: 2025-09-24 06:42 – Updated: 2025-09-24 13:10
    VLAI
    Title
    File Parsing Memory Corruption in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-24 13:09 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , < 2.1.0.34 (custom)
    Create a notification for this product.
    Date Public
    2025-09-24 06:02
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58319",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-24T13:09:42.496667Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-24T13:10:05.302Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "2.1.0.34",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Jessie Cooper of CISA"
            }
          ],
          "datePublic": "2025-09-24T06:02:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-24T06:42:08.525Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00017_CNCSoft-G2_File%20Parsing%20Stack-based%20Buffer%20Overflow%20Vulnerability.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Download and update to: v2.1.0.34 or later\u003cbr\u003e"
                }
              ],
              "value": "Download and update to: v2.1.0.34 or later"
            }
          ],
          "source": {
            "defect": [
              "CISA"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "File Parsing Memory Corruption in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-58319",
        "datePublished": "2025-09-24T06:42:08.525Z",
        "dateReserved": "2025-08-28T06:15:58.626Z",
        "dateUpdated": "2025-09-24T13:10:05.302Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-58317 (GCVE-0-2025-58317)

    Vulnerability from nvd – Published: 2025-09-24 06:38 – Updated: 2026-03-18 05:26
    VLAI
    Title
    File Parsing Memory Corruption in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-24 13:13 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , < 2.1.0.34 (custom)
    Create a notification for this product.
    Date Public
    2025-09-24 06:02
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58317",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-24T13:13:22.686691Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-24T13:13:34.500Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "2.1.0.34",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Natnael Samson working with Trend Micro Zero Day Initiative"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "CISA"
            }
          ],
          "datePublic": "2025-09-24T06:02:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-18T05:26:08.198Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00017_CNCSoft-G2_File%20Parsing%20Stack-based%20Buffer%20Overflow%20Vulnerability.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Download and update to: v2.1.0.34 or later\u003cbr\u003e"
                }
              ],
              "value": "Download and update to: v2.1.0.34 or later"
            }
          ],
          "source": {
            "defect": [
              "CISA"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "File Parsing Memory Corruption in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-58317",
        "datePublished": "2025-09-24T06:38:43.161Z",
        "dateReserved": "2025-08-28T06:15:58.626Z",
        "dateUpdated": "2026-03-18T05:26:08.198Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-47728 (GCVE-0-2025-47728)

    Vulnerability from nvd – Published: 2025-06-04 08:11 – Updated: 2026-03-18 05:36
    VLAI
    Title
    File Parsing Memory Corruption in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-04 13:26 UTC
    CWE
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , < 2.1.0.27 (custom)
    Create a notification for this product.
    Date Public
    2025-06-04 08:05
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-47728",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-04T13:26:47.796513Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-04T13:26:55.450Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "2.1.0.27",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Kholoud Altookhy from Trend Micro\u0027s Zero Day Initiative"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "CISA"
            }
          ],
          "datePublic": "2025-06-04T08:05:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-18T05:36:26.384Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00007_CNCSoft-G2%20-%20File%20Parsing%20Memory%20Corruption.pdf"
            }
          ],
          "source": {
            "defect": [
              "CISA"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "File Parsing Memory Corruption in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-47728",
        "datePublished": "2025-06-04T08:11:06.007Z",
        "dateReserved": "2025-05-08T08:08:01.077Z",
        "dateUpdated": "2026-03-18T05:36:26.384Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-12858 (GCVE-0-2024-12858)

    Vulnerability from nvd – Published: 2025-03-13 16:47 – Updated: 2025-04-02 15:02
    VLAI

    This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. *** Duplicate of CVE-2025-22880 ***

    Show details on NVD website

    {
      "containers": {
        "cna": {
          "providerMetadata": {
            "dateUpdated": "2025-04-02T15:02:50.433Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "rejectedReasons": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.\u003cbr\u003e*** Duplicate of \nCVE-2025-22880\n\n***"
                }
              ],
              "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.\n*** Duplicate of \nCVE-2025-22880\n\n***"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-12858",
        "datePublished": "2025-03-13T16:47:43.636Z",
        "dateRejected": "2025-04-02T15:02:50.433Z",
        "dateReserved": "2024-12-20T16:52:15.306Z",
        "dateUpdated": "2025-04-02T15:02:50.433Z",
        "state": "REJECTED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22881 (GCVE-0-2025-22881)

    Vulnerability from nvd – Published: 2025-02-26 01:44 – Updated: 2025-02-26 15:43
    VLAI
    Title
    Heap-based Buffer Overflow in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-26 14:49 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , ≤ 2.1.0.10 (custom)
    Create a notification for this product.
    Date Public
    2025-02-26 01:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22881",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-26T14:49:19.074255Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-26T15:43:08.047Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "2.1.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2025-02-26T01:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-44",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-44 Overflow Binary Resource File"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-02-26T01:44:17.551Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00003_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Heap-based Buffer Overflow in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-22881",
        "datePublished": "2025-02-26T01:44:17.551Z",
        "dateReserved": "2025-01-09T03:48:26.774Z",
        "dateUpdated": "2025-02-26T15:43:08.047Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22880 (GCVE-0-2025-22880)

    Vulnerability from nvd – Published: 2025-02-07 07:26 – Updated: 2025-02-07 15:54
    VLAI
    Title
    Heap-based Buffer Overflow in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-07 15:49 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , < 2.1.0.20 (custom)
    Create a notification for this product.
    Date Public
    2025-02-07 07:20
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22880",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-07T15:49:27.000208Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-07T15:54:27.041Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "2.1.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2025-02-07T07:20:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-44",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-44 Overflow Binary Resource File"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-02-07T07:26:04.691Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00002_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2024-09-28T06:24:00.000Z",
              "value": "Reported"
            },
            {
              "lang": "en",
              "time": "2024-12-04T06:26:00.000Z",
              "value": "New patch (CNCSoft-G2 v2.1.0.20) released"
            }
          ],
          "title": "Heap-based Buffer Overflow in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-22880",
        "datePublished": "2025-02-07T07:26:04.691Z",
        "dateReserved": "2025-01-09T03:48:26.774Z",
        "dateUpdated": "2025-02-07T15:54:27.041Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47966 (GCVE-0-2024-47966)

    Vulnerability from nvd – Published: 2024-10-10 17:18 – Updated: 2024-10-10 17:37
    VLAI
    Title
    Use of Uninitialized Variable vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:35 UTC
    CWE
    • CWE-457 - Use of Uninitialized Variable
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47966",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:35:10.512564Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:37:04.833Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-457",
                  "description": "CWE-457 Use of Uninitialized Variable",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:18:58.817Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Use of Uninitialized Variable vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47966",
        "datePublished": "2024-10-10T17:18:58.817Z",
        "dateReserved": "2024-10-07T17:01:16.643Z",
        "dateUpdated": "2024-10-10T17:37:04.833Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47965 (GCVE-0-2024-47965)

    Vulnerability from nvd – Published: 2024-10-10 17:18 – Updated: 2024-10-10 17:41
    VLAI
    Title
    Out-of-bounds Read vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:40 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47965",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:40:16.943724Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:41:01.289Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:18:01.407Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Out-of-bounds Read vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47965",
        "datePublished": "2024-10-10T17:18:01.407Z",
        "dateReserved": "2024-10-07T17:01:16.642Z",
        "dateUpdated": "2024-10-10T17:41:01.289Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47964 (GCVE-0-2024-47964)

    Vulnerability from nvd – Published: 2024-10-10 17:16 – Updated: 2024-10-10 17:42
    VLAI
    Title
    Heap-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:41 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47964",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:41:41.260226Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:42:30.381Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:16:51.747Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Heap-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47964",
        "datePublished": "2024-10-10T17:16:51.747Z",
        "dateReserved": "2024-10-07T17:01:16.642Z",
        "dateUpdated": "2024-10-10T17:42:30.381Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47963 (GCVE-0-2024-47963)

    Vulnerability from nvd – Published: 2024-10-10 17:15 – Updated: 2024-10-10 17:43
    VLAI
    Title
    Out-of-bounds Write vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:43 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47963",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:43:14.190343Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:43:56.182Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:15:54.044Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Out-of-bounds Write vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47963",
        "datePublished": "2024-10-10T17:15:54.044Z",
        "dateReserved": "2024-10-07T17:01:16.642Z",
        "dateUpdated": "2024-10-10T17:43:56.182Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47962 (GCVE-0-2024-47962)

    Vulnerability from nvd – Published: 2024-10-10 17:14 – Updated: 2024-10-10 17:45
    VLAI
    Title
    Stack-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:44 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47962",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:44:29.384286Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:45:02.444Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:14:30.805Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Stack-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47962",
        "datePublished": "2024-10-10T17:14:30.805Z",
        "dateReserved": "2024-10-07T17:01:16.642Z",
        "dateUpdated": "2024-10-10T17:45:02.444Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39883 (GCVE-0-2024-39883)

    Vulnerability from nvd – Published: 2024-07-09 21:25 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Heap-based Buffer Overflow in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-11 14:24 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.0.0.5
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.0.0.5
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.0.0.5"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39883",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-11T14:24:25.123528Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:58.407Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T04:33:11.201Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.0.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T21:25:49.165Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Heap-based Buffer Overflow in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-39883",
        "datePublished": "2024-07-09T21:25:49.165Z",
        "dateReserved": "2024-07-01T18:13:23.097Z",
        "dateUpdated": "2025-08-27T20:42:58.407Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39882 (GCVE-0-2024-39882)

    Vulnerability from nvd – Published: 2024-07-09 21:25 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Out-of-bounds Read in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-23 18:55 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.0.0.5
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.0.0.5
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.0.0.5"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39882",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-23T18:55:11.251122Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:58.211Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T04:33:10.314Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.0.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T21:25:02.237Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Out-of-bounds Read in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-39882",
        "datePublished": "2024-07-09T21:25:02.237Z",
        "dateReserved": "2024-07-01T18:13:23.097Z",
        "dateUpdated": "2025-08-27T20:42:58.211Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39881 (GCVE-0-2024-39881)

    Vulnerability from nvd – Published: 2024-07-09 21:23 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Out-of-bounds Write in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-10 15:22 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.0.0.5
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.0.0.5
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.0.0.5"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39881",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-10T15:22:25.578143Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:58.039Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T04:33:11.245Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.0.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T21:23:31.171Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Out-of-bounds Write in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-39881",
        "datePublished": "2024-07-09T21:23:31.171Z",
        "dateReserved": "2024-07-01T18:13:23.097Z",
        "dateUpdated": "2025-08-27T20:42:58.039Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39880 (GCVE-0-2024-39880)

    Vulnerability from nvd – Published: 2024-07-09 21:21 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Stack-based Buffer Overflow in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-10 13:58 UTC
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.0.0.5
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.0.0.5
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.0.0.5"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39880",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-10T13:58:44.937267Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:57.877Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T04:33:11.485Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.0.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T23:12:00.978Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Stack-based Buffer Overflow in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-39880",
        "datePublished": "2024-07-09T21:21:47.678Z",
        "dateReserved": "2024-07-01T18:13:23.097Z",
        "dateUpdated": "2025-08-27T20:42:57.877Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-58319 (GCVE-0-2025-58319)

    Vulnerability from cvelistv5 – Published: 2025-09-24 06:42 – Updated: 2025-09-24 13:10
    VLAI
    Title
    File Parsing Memory Corruption in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-24 13:09 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , < 2.1.0.34 (custom)
    Create a notification for this product.
    Date Public
    2025-09-24 06:02
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58319",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-24T13:09:42.496667Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-24T13:10:05.302Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "2.1.0.34",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Jessie Cooper of CISA"
            }
          ],
          "datePublic": "2025-09-24T06:02:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-24T06:42:08.525Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00017_CNCSoft-G2_File%20Parsing%20Stack-based%20Buffer%20Overflow%20Vulnerability.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Download and update to: v2.1.0.34 or later\u003cbr\u003e"
                }
              ],
              "value": "Download and update to: v2.1.0.34 or later"
            }
          ],
          "source": {
            "defect": [
              "CISA"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "File Parsing Memory Corruption in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-58319",
        "datePublished": "2025-09-24T06:42:08.525Z",
        "dateReserved": "2025-08-28T06:15:58.626Z",
        "dateUpdated": "2025-09-24T13:10:05.302Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-58317 (GCVE-0-2025-58317)

    Vulnerability from cvelistv5 – Published: 2025-09-24 06:38 – Updated: 2026-03-18 05:26
    VLAI
    Title
    File Parsing Memory Corruption in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-09-24 13:13 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , < 2.1.0.34 (custom)
    Create a notification for this product.
    Date Public
    2025-09-24 06:02
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58317",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-24T13:13:22.686691Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-24T13:13:34.500Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "2.1.0.34",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Natnael Samson working with Trend Micro Zero Day Initiative"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "CISA"
            }
          ],
          "datePublic": "2025-09-24T06:02:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-18T05:26:08.198Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00017_CNCSoft-G2_File%20Parsing%20Stack-based%20Buffer%20Overflow%20Vulnerability.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Download and update to: v2.1.0.34 or later\u003cbr\u003e"
                }
              ],
              "value": "Download and update to: v2.1.0.34 or later"
            }
          ],
          "source": {
            "defect": [
              "CISA"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "File Parsing Memory Corruption in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-58317",
        "datePublished": "2025-09-24T06:38:43.161Z",
        "dateReserved": "2025-08-28T06:15:58.626Z",
        "dateUpdated": "2026-03-18T05:26:08.198Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-47728 (GCVE-0-2025-47728)

    Vulnerability from cvelistv5 – Published: 2025-06-04 08:11 – Updated: 2026-03-18 05:36
    VLAI
    Title
    File Parsing Memory Corruption in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-04 13:26 UTC
    CWE
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , < 2.1.0.27 (custom)
    Create a notification for this product.
    Date Public
    2025-06-04 08:05
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-47728",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-04T13:26:47.796513Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-04T13:26:55.450Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "2.1.0.27",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Kholoud Altookhy from Trend Micro\u0027s Zero Day Initiative"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "CISA"
            }
          ],
          "datePublic": "2025-06-04T08:05:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-18T05:36:26.384Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00007_CNCSoft-G2%20-%20File%20Parsing%20Memory%20Corruption.pdf"
            }
          ],
          "source": {
            "defect": [
              "CISA"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "File Parsing Memory Corruption in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-47728",
        "datePublished": "2025-06-04T08:11:06.007Z",
        "dateReserved": "2025-05-08T08:08:01.077Z",
        "dateUpdated": "2026-03-18T05:36:26.384Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-12858 (GCVE-0-2024-12858)

    Vulnerability from cvelistv5 – Published: 2025-03-13 16:47 – Updated: 2025-04-02 15:02
    VLAI

    This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. *** Duplicate of CVE-2025-22880 ***

    Show details on NVD website

    {
      "containers": {
        "cna": {
          "providerMetadata": {
            "dateUpdated": "2025-04-02T15:02:50.433Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "rejectedReasons": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.\u003cbr\u003e*** Duplicate of \nCVE-2025-22880\n\n***"
                }
              ],
              "value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.\n*** Duplicate of \nCVE-2025-22880\n\n***"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-12858",
        "datePublished": "2025-03-13T16:47:43.636Z",
        "dateRejected": "2025-04-02T15:02:50.433Z",
        "dateReserved": "2024-12-20T16:52:15.306Z",
        "dateUpdated": "2025-04-02T15:02:50.433Z",
        "state": "REJECTED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22881 (GCVE-0-2025-22881)

    Vulnerability from cvelistv5 – Published: 2025-02-26 01:44 – Updated: 2025-02-26 15:43
    VLAI
    Title
    Heap-based Buffer Overflow in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-26 14:49 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , ≤ 2.1.0.10 (custom)
    Create a notification for this product.
    Date Public
    2025-02-26 01:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22881",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-26T14:49:19.074255Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-26T15:43:08.047Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "2.1.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2025-02-26T01:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-44",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-44 Overflow Binary Resource File"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-02-26T01:44:17.551Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00003_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Heap-based Buffer Overflow in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-22881",
        "datePublished": "2025-02-26T01:44:17.551Z",
        "dateReserved": "2025-01-09T03:48:26.774Z",
        "dateUpdated": "2025-02-26T15:43:08.047Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-22880 (GCVE-0-2025-22880)

    Vulnerability from cvelistv5 – Published: 2025-02-07 07:26 – Updated: 2025-02-07 15:54
    VLAI
    Title
    Heap-based Buffer Overflow in CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-07 15:49 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 0 , < 2.1.0.20 (custom)
    Create a notification for this product.
    Date Public
    2025-02-07 07:20
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-22880",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-07T15:49:27.000208Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-07T15:54:27.041Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "2.1.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2025-02-07T07:20:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-44",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-44 Overflow Binary Resource File"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-02-07T07:26:04.691Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00002_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2024-09-28T06:24:00.000Z",
              "value": "Reported"
            },
            {
              "lang": "en",
              "time": "2024-12-04T06:26:00.000Z",
              "value": "New patch (CNCSoft-G2 v2.1.0.20) released"
            }
          ],
          "title": "Heap-based Buffer Overflow in CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-22880",
        "datePublished": "2025-02-07T07:26:04.691Z",
        "dateReserved": "2025-01-09T03:48:26.774Z",
        "dateUpdated": "2025-02-07T15:54:27.041Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47966 (GCVE-0-2024-47966)

    Vulnerability from cvelistv5 – Published: 2024-10-10 17:18 – Updated: 2024-10-10 17:37
    VLAI
    Title
    Use of Uninitialized Variable vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:35 UTC
    CWE
    • CWE-457 - Use of Uninitialized Variable
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47966",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:35:10.512564Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:37:04.833Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-457",
                  "description": "CWE-457 Use of Uninitialized Variable",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:18:58.817Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Use of Uninitialized Variable vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47966",
        "datePublished": "2024-10-10T17:18:58.817Z",
        "dateReserved": "2024-10-07T17:01:16.643Z",
        "dateUpdated": "2024-10-10T17:37:04.833Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47965 (GCVE-0-2024-47965)

    Vulnerability from cvelistv5 – Published: 2024-10-10 17:18 – Updated: 2024-10-10 17:41
    VLAI
    Title
    Out-of-bounds Read vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:40 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47965",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:40:16.943724Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:41:01.289Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:18:01.407Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Out-of-bounds Read vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47965",
        "datePublished": "2024-10-10T17:18:01.407Z",
        "dateReserved": "2024-10-07T17:01:16.642Z",
        "dateUpdated": "2024-10-10T17:41:01.289Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47964 (GCVE-0-2024-47964)

    Vulnerability from cvelistv5 – Published: 2024-10-10 17:16 – Updated: 2024-10-10 17:42
    VLAI
    Title
    Heap-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:41 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47964",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:41:41.260226Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:42:30.381Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:16:51.747Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Heap-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47964",
        "datePublished": "2024-10-10T17:16:51.747Z",
        "dateReserved": "2024-10-07T17:01:16.642Z",
        "dateUpdated": "2024-10-10T17:42:30.381Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47963 (GCVE-0-2024-47963)

    Vulnerability from cvelistv5 – Published: 2024-10-10 17:15 – Updated: 2024-10-10 17:43
    VLAI
    Title
    Out-of-bounds Write vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:43 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47963",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:43:14.190343Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:43:56.182Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:15:54.044Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Out-of-bounds Write vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47963",
        "datePublished": "2024-10-10T17:15:54.044Z",
        "dateReserved": "2024-10-07T17:01:16.642Z",
        "dateUpdated": "2024-10-10T17:43:56.182Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-47962 (GCVE-0-2024-47962)

    Vulnerability from cvelistv5 – Published: 2024-10-10 17:14 – Updated: 2024-10-10 17:45
    VLAI
    Title
    Stack-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-10-10 17:44 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.1.0.10
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.1.0.10
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.1.0.10"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-47962",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-10T17:44:29.384286Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-10T17:45:02.444Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.1.0.10"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-10T17:14:30.805Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Stack-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-47962",
        "datePublished": "2024-10-10T17:14:30.805Z",
        "dateReserved": "2024-10-07T17:01:16.642Z",
        "dateUpdated": "2024-10-10T17:45:02.444Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39883 (GCVE-0-2024-39883)

    Vulnerability from cvelistv5 – Published: 2024-07-09 21:25 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Heap-based Buffer Overflow in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-11 14:24 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.0.0.5
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.0.0.5
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.0.0.5"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39883",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-11T14:24:25.123528Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:58.407Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T04:33:11.201Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.0.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T21:25:49.165Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Heap-based Buffer Overflow in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-39883",
        "datePublished": "2024-07-09T21:25:49.165Z",
        "dateReserved": "2024-07-01T18:13:23.097Z",
        "dateUpdated": "2025-08-27T20:42:58.407Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39882 (GCVE-0-2024-39882)

    Vulnerability from cvelistv5 – Published: 2024-07-09 21:25 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Out-of-bounds Read in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-23 18:55 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.0.0.5
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.0.0.5
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.0.0.5"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39882",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-23T18:55:11.251122Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:58.211Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T04:33:10.314Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.0.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T21:25:02.237Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Out-of-bounds Read in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-39882",
        "datePublished": "2024-07-09T21:25:02.237Z",
        "dateReserved": "2024-07-01T18:13:23.097Z",
        "dateUpdated": "2025-08-27T20:42:58.211Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39881 (GCVE-0-2024-39881)

    Vulnerability from cvelistv5 – Published: 2024-07-09 21:23 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Out-of-bounds Write in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-10 15:22 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.0.0.5
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.0.0.5
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.0.0.5"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39881",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-10T15:22:25.578143Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:58.039Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T04:33:11.245Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.0.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T21:23:31.171Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Out-of-bounds Write in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-39881",
        "datePublished": "2024-07-09T21:23:31.171Z",
        "dateReserved": "2024-07-01T18:13:23.097Z",
        "dateUpdated": "2025-08-27T20:42:58.039Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-39880 (GCVE-0-2024-39880)

    Vulnerability from cvelistv5 – Published: 2024-07-09 21:21 – Updated: 2025-08-27 20:42
    VLAI
    Title
    Stack-based Buffer Overflow in Delta Electronics CNCSoft-G2
    Summary
    Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-07-10 13:58 UTC
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    References
    Impacted products
    Vendor Product Version
    Delta Electronics CNCSoft-G2 Affected: 2.0.0.5
    Create a notification for this product.
    delta_electronics cncsoft-g2 Affected: 2.0.0.5
        cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "cncsoft-g2",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "status": "affected",
                    "version": "2.0.0.5"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39880",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-10T13:58:44.937267Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-27T20:42:57.877Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T04:33:11.485Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CNCSoft-G2",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.0.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T23:12:00.978Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Stack-based Buffer Overflow in Delta Electronics CNCSoft-G2",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-39880",
        "datePublished": "2024-07-09T21:21:47.678Z",
        "dateReserved": "2024-07-01T18:13:23.097Z",
        "dateUpdated": "2025-08-27T20:42:57.877Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }