    7 vulnerabilities found for SINAMICS G110M by Siemens

    VAR-201910-1595

    Vulnerability from variot - Updated: 2023-12-18 13:13

    A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler, SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. Affected devices improperly handle large amounts of specially crafted UDP packets.

    This could allow an unauthenticated remote attacker to trigger a denial of service condition. Several Siemens products are vulnerable to resource exhaustion.Denial of service (DoS) May be in a state. Siemens SIMATIC CFU PA and so on are the products of Germany's Siemens company. Siemens SIMATIC CFU PA is a compact field device. SIMATIC ET 200AL is a distributed I / O system module. SIMATIC ET 200M is a modular I / O system module for control cabinets for high density channel applications. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions < V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions < V4.3.0), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions < V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions < V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions < V2.1), SIMATIC S7-1200 CPU family (incl. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-1500 CPU series (including: related ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller; SIMATIC TDC CP51M1; SIMATIC TDC CPU555; SINAMICS DCM, etc

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201910-1595",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "simatic cfu pa",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "siemens",
            "version": "1.2.0"
          },
          {
            "model": "simatic profinet driver",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "siemens",
            "version": "2.1"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200al",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200m",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200s",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 1.0,
            "vendor": "sinumerik 828d",
            "version": "4.8"
          },
          {
            "model": "simatic s7-1500t cpu",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "sinamics g150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2"
          },
          {
            "model": "simatic s7-410 v8",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "8.2.2"
          },
          {
            "model": "sinamics g130",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2"
          },
          {
            "model": "simatic winac rtx \\",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics dcp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.3"
          },
          {
            "model": "simatic hmi ktp mobile panels",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic et 200sp im 155-6 pn st",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic et 200sp im 155-6 pn hs",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic pn\\/pn coupler",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.1"
          },
          {
            "model": "sinamics s150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2"
          },
          {
            "model": "simatic s7-300 cpu 314 ifm",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-300 cpu 318-2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinamics gl150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic hmi comfort panels 4\\\"",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic et 200pro",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-300 cpu 313",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinamics sl150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic hmi comfort outdoor panels 7\\\"",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinumerik 828d",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic s7-400 dp v7",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic et 200m",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic et 200sp im 155-6 pn ha",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-400h v6",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.0.9"
          },
          {
            "model": "simatic et 200sp im 155-6 pn ba",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics g110m",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic et 200mp im 155-5 pn ba",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.3.0"
          },
          {
            "model": "simatic et 200s",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics gm150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic s7-300 cpu 316-2 dp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinamics g120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic et 200sp im 155-6 pn\\/3 hf",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.1"
          },
          {
            "model": "simatic s7-1500s cpu",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "simatic hmi comfort outdoor panels 15\\\"",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-300 cpu",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "simatic s7-300 cpu 314",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinamics gl150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics g110m",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 828d",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic s7-400 v6",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.0.9"
          },
          {
            "model": "simatic et 200mp im 155-5 pn hf",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4.0"
          },
          {
            "model": "sinamics g120",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic s7-300 cpu 315-2 dp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "simatic et 200al",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-300 cpu 312 ifm",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "simatic s7-300 cpu 315",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "simatic s7-1500 cpu",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "simatic hmi comfort panels 22\\\"",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics s110",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-1500 cpu 1512c",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "simatic s7-1200 cpu 1212c",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4.0"
          },
          {
            "model": "ek-ertec 200p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.6"
          },
          {
            "model": "sinamics g150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2"
          },
          {
            "model": "sinamics gm150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic et 200ecopn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics dcm",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.5"
          },
          {
            "model": "ek-ertec 200",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic et 200sp im 155-6 pn\\/2 hf",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.2"
          },
          {
            "model": "ek-ertec 200p",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.6"
          },
          {
            "model": "sinamics sm120",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400 pn v7",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic winac rtx \\",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "simatic s7-1500 cpu 1518",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "simatic s7-1500 cpu 1511c",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "sinamics s150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2"
          },
          {
            "model": "simatic s7-1200 cpu 1211c",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4.0"
          },
          {
            "model": "sinamics s120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2"
          },
          {
            "model": "sinamics g130",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2"
          },
          {
            "model": "simatic s7-1200 cpu",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4.0"
          },
          {
            "model": "simatic et 200mp im 155-5 pn st",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-1200 cpu 1214c",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4.0"
          },
          {
            "model": "sinamics s120",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2"
          },
          {
            "model": "simatic et 200sp im 155-6 pn hf",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.2"
          },
          {
            "model": "sinamics dcm",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.5"
          },
          {
            "model": "ek-ertec 200",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200p p",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cfu pa",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200mp im 155-5 pn ba",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200mp im 155-5 pn hf",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200mp im 155-5 pn st",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1200 cpu family",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "200"
          },
          {
            "model": "ek-ertec 200p",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200mp im pn ba",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-5\u003c4.2.3"
          },
          {
            "model": "simatic et 200mp im pn hf",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-5"
          },
          {
            "model": "simatic et 200mp im pn st",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-5"
          },
          {
            "model": "simatic et 200sp im pn ba",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-6"
          },
          {
            "model": "simatic et 200sp im pn ha",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-6"
          },
          {
            "model": "simatic et 200sp im pn hf",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-6\u003c4.2.2"
          },
          {
            "model": "simatic et 200sp im pn hs",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-6"
          },
          {
            "model": "simatic et 200sp im pn st",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-6"
          },
          {
            "model": "simatic et 200sp im pn/2 hf",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-6\u003c4.2.2"
          },
          {
            "model": "simatic et 200sp im pn/3 hf",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "155-6\u003c4.2.1"
          },
          {
            "model": "simatic et 200ecopn",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200pro",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\"",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic hmi comfort panels 4\" 22\"",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic hmi ktp mobile panels",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic pn/pn coupler",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1500 cpu family",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-300 cpu family",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400 pn/dp",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v7"
          },
          {
            "model": "simatic s7-400 and below",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v6"
          },
          {
            "model": "simatic s7-400h",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v6\u003c6.0.9"
          },
          {
            "model": "simatic s7-410",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v8"
          },
          {
            "model": "simatic winac rtx",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "sinamics dcm",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcp",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g110m sp10 hf5",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7\u003cv4.7"
          },
          {
            "model": "sinamics g120 sp10 hf5",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7\u003cv4.7"
          },
          {
            "model": "sinamics g130",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics g150",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics gh150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics gl150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics gm150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics s110",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s120",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics s150",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics sm120",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinumerik 828d sp5",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.8"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dk standard ethernet controller",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200s",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp im 155 6 pn ba",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp im 155 6 pn ha",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp im 155 6 pn hf",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp im 155 6 pn hs",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp im 155 6 pn st",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp im 155 6 pn 2 hf",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp im 155 6 pn 3 hf",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200ecopn",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200pro",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi comfort outdoor panels 7",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi comfort outdoor panels 15",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi comfort panels 4",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi comfort panels 22",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi ktp mobile panels",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic pn pn coupler",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic profinet driver",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1200 cpu",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1200 cpu 1211c",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1200 cpu 1212c",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200p",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1200 cpu 1214c",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500 cpu",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500s cpu",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500t cpu",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500 cpu 1518",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500 cpu 1511c",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500 cpu 1512c",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 312 ifm",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 313",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cfu pa",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 314",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 314 ifm",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 315",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 315 2 dp",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 316 2 dp",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 318 2",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400 pn v7",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400 dp v7",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400 v6",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400h v6",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200al",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 410 v8",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic winac rtx f 2010",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcm",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcm",
            "version": "1.5"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcp",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g110m",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g120",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g130",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics gl150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics gm150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200m",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s110",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s120",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics sl150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics sm120",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinumerik 828d",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinumerik 840d sl",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200mp im 155 5 pn ba",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200mp im 155 5 pn hf",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200mp im 155 5 pn st",
            "version": "*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10936"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.6",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:4.6:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_ba_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.3.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_ba:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.4.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_hf:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_st:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ba_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ba:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ha:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hf_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.2.2",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hf:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hs_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hs:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_st_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_st:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.2.2",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.4.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.4.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.4.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.4.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500s_cpu_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500s_cpu:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500t_cpu_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500t_cpu:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.0.9",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.0.9",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "8.2.2",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2010",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.5",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "5.2",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:5.2:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "5.2",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:5.2:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "5.2",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "5.2",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.2:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-10936"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens reported this vulnerability to CISA.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-639"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2019-10936",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 5.0,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2019-10936",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-36853",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "ea2714fa-253a-4380-82d5-35652a5540fb",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "VHN-142532",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2019-10936",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-10936",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2019-10936",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-36853",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201910-639",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "ea2714fa-253a-4380-82d5-35652a5540fb",
                "trust": 0.2,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-142532",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10936"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10936"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-639"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in  SIMATIC S7-400 CPU 414-3 PN/DP V7,  SIMATIC S7-400 CPU 414F-3 PN/DP V7,  SIMATIC S7-400 CPU 416-3 PN/DP V7,  SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler, SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. Affected devices improperly handle large amounts of specially crafted UDP packets. \r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition. Several Siemens products are vulnerable to resource exhaustion.Denial of service (DoS) May be in a state. Siemens SIMATIC CFU PA and so on are the products of Germany\u0027s Siemens company. Siemens SIMATIC CFU PA is a compact field device. SIMATIC ET 200AL is a distributed I / O system module. SIMATIC ET 200M is a modular I / O system module for control cabinets for high density channel applications. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions \u003c V1.2.0), SIMATIC ET 200AL (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM 155-5 PN BA (All versions \u003c V4.3.0), SIMATIC ET 200MP IM 155-5 PN HF (All versions), SIMATIC ET 200MP IM 155-5 PN ST (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM 155-6 PN BA (All versions), SIMATIC ET 200SP IM 155-6 PN HA (All versions), SIMATIC ET 200SP IM 155-6 PN HF (All versions \u003c V4.2.2), SIMATIC ET 200SP IM 155-6 PN HS (All versions), SIMATIC ET 200SP IM 155-6 PN ST (All versions), SIMATIC ET 200SP IM 155-6 PN/2 HF (All versions \u003c V4.2.2), SIMATIC ET 200SP IM 155-6 PN/3 HF (All versions \u003c V4.2.1), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions), SIMATIC HMI Comfort Panels 4\" - 22\" (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (All versions), SIMATIC PROFINET Driver (All versions \u003c V2.1), SIMATIC S7-1200 CPU family (incl. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. The following products and versions are affected: Siemens SIMATIC S7-1500 CPU series (including: related ET200 CPUs and SIPLUS variants); SIMATIC S7-1500 Software Controller; SIMATIC TDC CP51M1; SIMATIC TDC CPU555; SINAMICS DCM, etc",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-10936"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "db": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142532"
          }
        ],
        "trust": 2.43
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-10936",
            "trust": 3.3
          },
          {
            "db": "SIEMENS",
            "id": "SSA-473245",
            "trust": 1.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-19-283-02",
            "trust": 1.4
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-639",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605",
            "trust": 0.8
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2019.3813",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2019.3813.3",
            "trust": 0.6
          },
          {
            "db": "IVD",
            "id": "EA2714FA-253A-4380-82D5-35652A5540FB",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-142532",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10936"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-639"
          }
        ]
      },
      "id": "VAR-201910-1595",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142532"
          }
        ],
        "trust": 1.633110274222222
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          }
        ]
      },
      "last_update_date": "2023-12-18T13:13:13.201000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SSA-473245",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
          },
          {
            "title": "Patch for Multiple Siemens Product Denial of Service Vulnerabilities (CNVD-2019-36853)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/186551"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-400",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-142532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10936"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-283-02"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10936"
          },
          {
            "trust": 1.2,
            "url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-profinet-udp-packets-30562"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10936"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2019.3813/"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-283-02"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2019.3813.3/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10936"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-639"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142532"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10936"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-639"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-10-23T00:00:00",
            "db": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
          },
          {
            "date": "2019-10-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "date": "2019-10-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-142532"
          },
          {
            "date": "2019-10-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          },
          {
            "date": "2019-10-10T14:15:14.707000",
            "db": "NVD",
            "id": "CVE-2019-10936"
          },
          {
            "date": "2019-10-09T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201910-639"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-10-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-36853"
          },
          {
            "date": "2023-01-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-142532"
          },
          {
            "date": "2019-11-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          },
          {
            "date": "2023-05-09T13:15:13.053000",
            "db": "NVD",
            "id": "CVE-2019-10936"
          },
          {
            "date": "2023-05-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201910-639"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-639"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Multiple Siemens products vulnerable to resource depletion",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010605"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Resource management error",
        "sources": [
          {
            "db": "IVD",
            "id": "ea2714fa-253a-4380-82d5-35652a5540fb"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-639"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201712-0703

    Vulnerability from variot - Updated: 2023-12-18 12:51

    A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants), SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually. plural Siemens The product contains data processing vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensSIMATICS7-200Smart and others are products of Siemens AG. The Siemens SIMATICS7-200Smart is a programmable logic controller (PLC) for use in small and medium-sized automation systems. SIMATICWinACRTX2010incl is a software controller for automation solutions. A denial of service vulnerability exists in several Siemens products. Attackers can exploit this issue to crash the affected device, denying service to legitimate users. A vulnerability has been identified in SIMATIC S7-200 Smart (All versions < V2.03.01), SIMATIC S7-400 PN V6 (All versions < V6.0.6), SIMATIC S7-400 H V6 (All versions < V6.0.8), SIMATIC S7-400 PN/DP V7 (All versions < V7.0.2), SIMATIC S7-410 V8 (All versions < V8.2.1), SIMATIC S7-300 (All versions < V3.X.16), SIMATIC S7-1200 (All versions < V4.2.3), SIMATIC S7-1500 (All versions < V2.0), SIMATIC S7-1500 Software Controller (All versions < V2.0), SIMATIC WinAC RTX 2010 incl. F (All versions), SIMATIC ET 200AL (All versions), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions < V4.0.2), SIMATIC ET 200MP IM155-5 PN ST (All versions < V4.1), SIMATIC ET 200MP IM155-5 PN HF (All versions < V4.2), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN HF (All versions < V4.2.0), SIMATIC ET 200SP IM155-6 PN HA (All versions < V1.1.0), SIMATIC ET 200SP IM155-6 PN BA (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions), SIMATIC ET 200SP IM155-6 PN HS (All versions), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5), SIMOTION D (All versions < V5.1 HF1), SIMOTION C (All versions < V5.1 HF1), SIMOTION P V4.4 and V4.5 (All versions < V4.5 HF5), SIMOTION P V5 (All versions < V5.1 HF1), SINAMICS DCM w. PN (All versions < V1.2 HF2), SINAMICS G110M w. PN (All versions < V1.02), SINUMERIK 840D sl (All versions), SIMATIC Compact Field Unit (All versions), SIMATIC PN/PN Coupler (All versions < V4.2.0), SIMOCODE pro V PROFINET (All versions < V2.1.1), SIRIUS Soft Starter 3RW44 PN (All versions), SIMOCODE pro V EIP (All versions < V1.0.2). Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201712-0703",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "sinamics s120",
            "scope": "eq",
            "trust": 1.9,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s150 v4.8",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sirius soft starter 3rw44pn",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s110pn",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic compact field unit",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s150 v4.7",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics v90pn",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simocode pro v profinet",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic pn\\/pn coupler",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-300",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1200",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1500",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1500 software controller",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200al",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200ecopn",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200m",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200mp",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200pro",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200s",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcm",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcp",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200sp",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "dk standard ethernet controller",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s120",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinumerik 840d sl",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic compact field unit",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic pn/pn coupler",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sirius soft starter 3rw44 pn",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g150",
            "scope": "eq",
            "trust": 1.3,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g130",
            "scope": "eq",
            "trust": 1.3,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcm",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1200",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.03.01"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400h v6",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.0.8"
          },
          {
            "model": "simatic et 200sp",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200al",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g110m\\/g120pn",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic s7-1500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "simatic s7-1500 controller",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "simatic et 200mp",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400pn\\/dp v7",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400pn v6",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.0.6"
          },
          {
            "model": "simatic winac rtx f 2010",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200ecopn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200pro",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200pn io",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-300",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simotion p",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.1"
          },
          {
            "model": "simatic et 200m",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcp",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-410 v8",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "simatic et 200s",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simotion c",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.1"
          },
          {
            "model": "simotion d",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.1"
          },
          {
            "model": "ek-ertec 200 pn io",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200p p",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-200 smart",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400 pn v6",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400 pn/dp v7",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400h v6",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-410 v8",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic winac rtx 2010 incl. f",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simocode pro v profinet",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simotion c",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simotion d",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simotion p",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g110m",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g130",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g150",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s110 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s150 v4.7 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s150 v4.8 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics v90 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-200 smart",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2.03.01"
          },
          {
            "model": "simatic s7-400 pn",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v6\u003cv6.0.6"
          },
          {
            "model": "simatic s7-400 h",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v6"
          },
          {
            "model": "simatic s7-400 pn/dp",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v7"
          },
          {
            "model": "simatic s7-410",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v8"
          },
          {
            "model": "simatic winac rtx incl.f",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "ek-ertec pn io",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "200"
          },
          {
            "model": "simotion d hf1",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v5.1"
          },
          {
            "model": "simotion c hf1",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v5.1"
          },
          {
            "model": "simotion p hf1",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v5.1"
          },
          {
            "model": "sinamics g110m/g120 w.pn sp9 hf1",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "ek-ertec 200p",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.5"
          },
          {
            "model": "sinamics s110 w.pn",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics s150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.8"
          },
          {
            "model": "sinamics w.pn",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v90"
          },
          {
            "model": "simocode pro profinet",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v"
          },
          {
            "model": "sinamics g130 and g150",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "softnet profinet io",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sirius soft starter 3rw44 pn",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 840d",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinamics sm150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sm120",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7.5"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7.4"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics s150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s120",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinamics gm150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics gl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics gh150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics g120",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinamics dcm",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simotion",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simocode pro eip",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "v1.0.1"
          },
          {
            "model": "simocode pro eip",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "v1.0"
          },
          {
            "model": "simatic winac rtx",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "20100"
          },
          {
            "model": "simatic winac rtx f sp2",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "simatic winac rtx sp2",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "simatic s7-410",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "8"
          },
          {
            "model": "simatic s7-400 pn",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "v60"
          },
          {
            "model": "simatic s7-400 pn",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-400 h",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "v60"
          },
          {
            "model": "simatic s7-300",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-200",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-1500",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1.8.3"
          },
          {
            "model": "simatic s7-1500",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1.6"
          },
          {
            "model": "simatic s7-1500",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1.5.0"
          },
          {
            "model": "simatic s7-1500",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-1200",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.1.3"
          },
          {
            "model": "simatic s7-1200",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.0"
          },
          {
            "model": "simatic s7-1200",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "3.0.1"
          },
          {
            "model": "simatic s7-1200",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "3.0.0"
          },
          {
            "model": "simatic s7-1200",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic s7-1200",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2.0.3"
          },
          {
            "model": "simatic s7-1200",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2.0.2"
          },
          {
            "model": "simatic et",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2000"
          },
          {
            "model": "simatic compact field unit",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "profinet io",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1.4.1"
          },
          {
            "model": "profinet io",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinamics sm120 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics sl150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gm150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gl150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gh150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics g120p",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g120d",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g120c",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g120 update sp9 hf1",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics g110m",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simotion p hf1",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "5.1"
          },
          {
            "model": "simotion c hf1",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "5.1"
          },
          {
            "model": "simocode pro eip",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "v1.0.2"
          },
          {
            "model": "simatic s7-400 pn",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "v66.0.6"
          },
          {
            "model": "simatic s7-200 smart",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2.3.1"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 200",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic winac rtx f 2010",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200al",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200ecopn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200m",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200mp",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200pro",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200s",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dk standard ethernet controller",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200p",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400pn v6",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200pn io",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simotion d",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simotion c",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simotion p",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcm",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcp",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g110m g120pn",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g130",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g150",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s110pn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400h v6",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s120",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s150 v4 7",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s150 v4 8",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics v90pn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinumerik 840d sl",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic compact field unit",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic pn pn coupler",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simocode pro v profinet",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sirius soft starter 3rw44pn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400pn dp v7",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 410 v8",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1200",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500 controller",
            "version": "2.0"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "db": "BID",
            "id": "101964"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12741"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.03.01",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400pn_v6_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.0.6",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400pn_v6:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.0.8",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400pn\\/dp_v7_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400pn\\/dp_v7:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_controller_firmware:2.0:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_f_2010_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.5",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200pn_io_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simotion_d_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "5.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simotion_d:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simotion_c_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "5.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simotion_c:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simotion_p_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "5.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simotion_p:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m\\/g120pn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "4.7",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m\\/g120pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110pn_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_v4.7_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150_v4.7:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_v4.8_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150_v4.8:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_v90pn_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_v90pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_compact_field_unit_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_compact_field_unit:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44pn_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-12741"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens ProductCERT reported this vulnerability to NCCIC.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2017-12741",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 7.8,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2017-12741",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2017-36884",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "e2df32de-39ab-11e9-b092-000c29342cb1",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "VHN-103294",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2017-12741",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2017-12741",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-36884",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201711-1105",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "e2df32de-39ab-11e9-b092-000c29342cb1",
                "trust": 0.2,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-103294",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "db": "VULHUB",
            "id": "VHN-103294"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12741"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants), SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually. plural Siemens The product contains data processing vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensSIMATICS7-200Smart and others are products of Siemens AG. The Siemens SIMATICS7-200Smart is a programmable logic controller (PLC) for use in small and medium-sized automation systems. SIMATICWinACRTX2010incl is a software controller for automation solutions. A denial of service vulnerability exists in several Siemens products. \nAttackers can exploit this issue to crash the affected device, denying service to legitimate users. A vulnerability has been identified in SIMATIC S7-200 Smart (All versions \u003c V2.03.01), SIMATIC S7-400 PN V6 (All versions \u003c V6.0.6), SIMATIC S7-400 H V6 (All versions \u003c V6.0.8), SIMATIC S7-400 PN/DP V7 (All versions \u003c V7.0.2), SIMATIC S7-410 V8 (All versions \u003c V8.2.1), SIMATIC S7-300 (All versions \u003c V3.X.16), SIMATIC S7-1200 (All versions \u003c V4.2.3), SIMATIC S7-1500 (All versions \u003c V2.0), SIMATIC S7-1500 Software Controller (All versions \u003c V2.0), SIMATIC WinAC RTX 2010 incl. F (All versions), SIMATIC ET 200AL (All versions), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions \u003c V4.0.2), SIMATIC ET 200MP IM155-5 PN ST (All versions \u003c V4.1), SIMATIC ET 200MP IM155-5 PN HF (All versions \u003c V4.2), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN HF (All versions \u003c V4.2.0), SIMATIC ET 200SP IM155-6 PN HA (All versions \u003c V1.1.0), SIMATIC ET 200SP IM155-6 PN BA (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions), SIMATIC ET 200SP IM155-6 PN HS (All versions), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions \u003c V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions \u003c V4.5), SIMOTION D (All versions \u003c V5.1 HF1), SIMOTION C (All versions \u003c V5.1 HF1), SIMOTION P V4.4 and V4.5 (All versions \u003c V4.5 HF5), SIMOTION P V5 (All versions \u003c V5.1 HF1), SINAMICS DCM w. PN (All versions \u003c V1.2 HF2), SINAMICS G110M w. PN (All versions \u003c V1.02), SINUMERIK 840D sl (All versions), SIMATIC Compact Field Unit (All versions), SIMATIC PN/PN Coupler (All versions \u003c V4.2.0), SIMOCODE pro V PROFINET (All versions \u003c V2.1.1), SIRIUS Soft Starter 3RW44 PN (All versions), SIMOCODE pro V EIP (All versions \u003c V1.0.2). Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-12741"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "db": "BID",
            "id": "101964"
          },
          {
            "db": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
          },
          {
            "db": "VULHUB",
            "id": "VHN-103294"
          }
        ],
        "trust": 2.7
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-12741",
            "trust": 3.6
          },
          {
            "db": "BID",
            "id": "101964",
            "trust": 2.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-339-01",
            "trust": 2.3
          },
          {
            "db": "SIEMENS",
            "id": "SSA-346262",
            "trust": 2.0
          },
          {
            "db": "SIEMENS",
            "id": "SSA-546832",
            "trust": 2.0
          },
          {
            "db": "SIEMENS",
            "id": "SSA-141614",
            "trust": 1.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-18-128-01",
            "trust": 1.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-19-099-01",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798",
            "trust": 0.8
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2019.1206",
            "trust": 0.6
          },
          {
            "db": "IVD",
            "id": "E2DF32DE-39AB-11E9-B092-000C29342CB1",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-103294",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "db": "VULHUB",
            "id": "VHN-103294"
          },
          {
            "db": "BID",
            "id": "101964"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12741"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ]
      },
      "id": "VAR-201712-0703",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "db": "VULHUB",
            "id": "VHN-103294"
          }
        ],
        "trust": 1.5574432950000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          },
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:51:14.227000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SSA-346262",
            "trust": 0.8,
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-346262.pdf"
          },
          {
            "title": "Patches for multiple Siemens product denial of service vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/109849"
          },
          {
            "title": "Multiple Siemens Product security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=76771"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-400",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-19",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-103294"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12741"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.9,
            "url": "https://www.securityfocus.com/bid/101964"
          },
          {
            "trust": 2.3,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-339-01"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-128-01"
          },
          {
            "trust": 0.9,
            "url": "http://www.siemens.com/"
          },
          {
            "trust": 0.9,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-01"
          },
          {
            "trust": 0.9,
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-346262.pdf"
          },
          {
            "trust": 0.9,
            "url": "https://cert-portal.siemens.com/productcert/txt/ssa-546832.txt"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12741"
          },
          {
            "trust": 0.8,
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-01"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-12741"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/78750"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-339-01"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "db": "VULHUB",
            "id": "VHN-103294"
          },
          {
            "db": "BID",
            "id": "101964"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12741"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "db": "VULHUB",
            "id": "VHN-103294"
          },
          {
            "db": "BID",
            "id": "101964"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12741"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-12-12T00:00:00",
            "db": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
          },
          {
            "date": "2017-12-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "date": "2017-12-26T00:00:00",
            "db": "VULHUB",
            "id": "VHN-103294"
          },
          {
            "date": "2017-11-23T00:00:00",
            "db": "BID",
            "id": "101964"
          },
          {
            "date": "2018-01-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "date": "2017-12-26T04:29:13.707000",
            "db": "NVD",
            "id": "CVE-2017-12741"
          },
          {
            "date": "2017-11-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-12-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-36884"
          },
          {
            "date": "2020-08-14T00:00:00",
            "db": "VULHUB",
            "id": "VHN-103294"
          },
          {
            "date": "2019-04-10T07:00:00",
            "db": "BID",
            "id": "101964"
          },
          {
            "date": "2019-07-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          },
          {
            "date": "2022-02-09T16:15:08.687000",
            "db": "NVD",
            "id": "CVE-2017-12741"
          },
          {
            "date": "2022-02-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Siemens Data processing vulnerabilities in products",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-011798"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "resource management error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201711-1105"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201705-3221

    Vulnerability from variot - Updated: 2023-12-18 12:51

    Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. SIMATIC HMI is an industrial device from Siemens AG, Germany. The SIMATIC HMI panels are used for operator control and monitoring of machines and equipment. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. Attackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. A vulnerability has been identified in SIMATIC CP 343-1 Std (All versions), SIMATIC CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std (All versions < V3.2.17), SIMATIC CP 443-1 Adv (All versions < V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions < V2.1.82), SIMATIC CP 1243-1 IRC (All versions < V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions < V2.0), SIMATIC CM 1542SP-1 (All versions < V1.0.15), SIMATIC CP 1542SP-1 IRC (All versions < V1.0.15), SIMATIC CP 1543SP-1 (All versions < V1.0.15), SIMATIC CP 1543-1 (All versions < V2.1), SIMATIC RF650R (All versions < V3.0), SIMATIC RF680R (All versions < V3.0), SIMATIC RF685R (All versions < V3.0), SIMATIC CP 1616 (All versions < V2.7), SIMATIC CP 1604 (All versions < V2.7), SIMATIC DK-16xx PN IO (All versions < V2.7), SCALANCE X-200 (All versions < V5.2.2), SCALANCE X-200 IRT (All versions), SCALANCE X-300/X408 (All versions < V4.1.0), SCALANCE X414 (All versions < V3.10.2), SCALANCE XM400 (All versions < V6.1), SCALANCE XR500 (All versions < V6.1), SCALANCE W700 (All versions < V6.1), SCALANCE M-800, S615 (All versions < V4.03), Softnet PROFINET IO for PC-based Windows systems (All versions < V14 SP1), IE/PB-Link (All versions < V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions < V1.2.0), SITOP UPS1600 PROFINET (All versions < V2.2.0), SIMATIC ET 200AL (All versions < V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions < V4.0.1), SIMATIC ET 200MP IM155-5 PN ST (All versions < V4.1), SIMATIC ET 200MP (except IM155-5 PN BA and IM155-5 PN ST) (All versions), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions < V4.1.0), SIMATIC ET 200SP (except IM155-6 PN ST) (All versions), SIMATIC PN/PN Coupler (All versions < V4.0), Development/Evaluation Kit DK Standard Ethernet Controller (All versions < V4.1.1 Patch04), Development/Evaluation Kit EK-ERTEC 200P (All versions < V4.4.0 Patch01), Development/Evaluation Kit EK-ERTEC 200 (All versions < V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions < V2.3), SIMATIC S7-300 incl. F and T (All versions < V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions < V6.0.6), SIMATIC S7-400-H V6 (All versions < V6.0.7), SIMATIC S7-400 PN/DP V7 Incl. F (All versions < V7.0.2), SIMATIC S7-410 (All versions < V8.2), SIMATIC S7-1200 incl. F (All versions < V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions < V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions < V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft Starter 3RW44 PN (All versions), SIRIUS Motor Starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions < V2.0.0), SINAMICS DCM w. PN (All versions < V1.4 SP1 HF5), SINAMICS DCP w. PN (All versions < V1.2 HF 1), SINAMICS G110M w. PN (All versions < V4.7 SP6 HF3), SINAMICS G120(C/P/D) w. PN (All versions < V4.7 SP6 HF3), SINAMICS G130 V4.7 w. PN (All versions < V4.7 HF27), SINAMICS G150 V4.7 w. PN (V4.7: All versions < V4.7 HF27), SINAMICS G130 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS G150 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS S110 w. PN (All versions < V4.4 SP3 HF5), SINAMICS S120 V4.7 w. PN (All versions < V4.7 HF27), and others. Siemens SIMATIC S7-300 F, etc. Siemens SIMATIC S7-300 F is a process controller. SIMATIC HMI Comfort Panels are touch screens

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3221",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "sinumerik 828d",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 828d",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "simatic hmi comfort panels",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic hmi mobile panels",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 343-1 adv",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-1500 software controller",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1"
          },
          {
            "model": "simatic teleservice adapter ie basic modem",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic tdc cp51m1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.1.8"
          },
          {
            "model": "simatic cp 1543-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.0.15"
          },
          {
            "model": "simatic cp 1243-1 irc",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1.82"
          },
          {
            "model": "sinamics dcm",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.4"
          },
          {
            "model": "sirius act 3su1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.1.0"
          },
          {
            "model": "simatic rf680r",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic cp 1543sp-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.0.15"
          },
          {
            "model": "sinamics g120\\ pn",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic et 200al",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.0.2"
          },
          {
            "model": "simatic cp 1543sp-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1"
          },
          {
            "model": "simatic cp 443-1 adv",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.2.17"
          },
          {
            "model": "scalance x414",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.10.2"
          },
          {
            "model": "sinumerik 828d",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "softnet profinet io",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14"
          },
          {
            "model": "simatic et 200pro",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "ek-ertec 200 pn io",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.1"
          },
          {
            "model": "simatic cp 1243-1 dnp3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "scalance x300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.0"
          },
          {
            "model": "scalance s615",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.03"
          },
          {
            "model": "sinamics s110 pn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4"
          },
          {
            "model": "simatic s7-400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.0.6"
          },
          {
            "model": "simatic et 200m",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "ups1600 profinet",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.2.0"
          },
          {
            "model": "sinamics dcp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.2"
          },
          {
            "model": "simotion",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "sinamics dcm",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.4"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.1"
          },
          {
            "model": "sinamics s120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics g110m",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics g130",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "scalance xr500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.1"
          },
          {
            "model": "simatic s7-200 smart",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.3"
          },
          {
            "model": "simatic et 200s",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic cp 1243-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1.82"
          },
          {
            "model": "ek-ertec 200p pn io",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4.0"
          },
          {
            "model": "simatic dk-16xx pn io",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.7"
          },
          {
            "model": "simatic tdc cpu555",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.1.1"
          },
          {
            "model": "simatic cp 1616",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.7"
          },
          {
            "model": "sinamics s120",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic et 200sp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.0"
          },
          {
            "model": "sinamics g150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "scalance w700",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.1"
          },
          {
            "model": "simatic teleservice adapter ie advanced modem",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics g110m",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sirius motor starter m200d profinet",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "softnet profinet io",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14"
          },
          {
            "model": "sinamics g130",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 828d",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "scalance xm400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.1"
          },
          {
            "model": "sirius soft starter 3rw44 pn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic hmi multi panels",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "15.1"
          },
          {
            "model": "simatic winac rtx",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "simocode pro v profinet",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0.0"
          },
          {
            "model": "sinamics s110 pn",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4"
          },
          {
            "model": "simatic hmi mobile panels",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "15.1"
          },
          {
            "model": "simatic rf650r",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "ek-ertec 200 pn io",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.1"
          },
          {
            "model": "sinamics s150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics g150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic cp 343-1 lean",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.1.3"
          },
          {
            "model": "ie\\/pb-link",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "scalance x200 irt",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.4.0"
          },
          {
            "model": "pn\\/pn coupler",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.0"
          },
          {
            "model": "simatic cp 1604",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.7"
          },
          {
            "model": "simatic et 200ecopn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "ek-ertec 200p pn io",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4.0"
          },
          {
            "model": "ie\\/as-i link pn io",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic rf685r",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "sinamics v90 pn",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.01"
          },
          {
            "model": "simatic cp 443-1 std",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.2.17"
          },
          {
            "model": "sinamics s150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic s7-300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "simatic s7-1500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1"
          },
          {
            "model": "simatic cp 1243-1 iec",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic cm 1542sp-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.0.15"
          },
          {
            "model": "scalance x200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2.2"
          },
          {
            "model": "simatic s7-1200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.1"
          },
          {
            "model": "simatic cp 443-1 opc-ua",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic hmi comfort panels",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "15.1"
          },
          {
            "model": "scalance m-800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.03"
          },
          {
            "model": "simatic cp 343-1 std",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.1.3"
          },
          {
            "model": "simatic teleservice adapter standard modem",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simotion",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "sinamics dcp",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.2"
          },
          {
            "model": "scalance x408",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.0"
          },
          {
            "model": "sitop psu8600",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.2.0"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.1"
          },
          {
            "model": "simatic cp 1542sp-1 irc",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.0.15"
          },
          {
            "model": "simatic et 200mp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.0.1"
          },
          {
            "model": "simatic cm 1542-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "simatic winac rtx",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200 pn io",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200p pn io",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ie/as-i link pn io",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ie/pb-link",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "pn/pn coupler",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance m-800",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance s615",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance w700",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x200 irt",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x200",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x300",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x408",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x414",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance xm400",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance xr500",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cm 1542-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1243-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1542sp-1 irc",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1542sp-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1543-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1543sp-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1604",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1616",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 343-1 adv",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 343-1 lean",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 343-1 std",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 443-1 adv",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 443-1 opc-ua",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 443-1 std",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic dk-16xx pn io",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200al",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200ecopn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200m",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200mp",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200pro",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200s",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200sp",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic hmi multi panels",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic rf650r",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic rf680r",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic rf685r",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1200",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1500 software controller",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1500",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-200 smart",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-300",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic teleservice adapter ie advanced",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic teleservice adapter ie basic",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic teleservice adapter standard modem",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic winac rtx 2010",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simocode pro v profinet",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simotion",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcm",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcp",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g110m",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g120 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g130",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g150",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s110 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s120",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s150",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics v90 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinumerik 828d",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinumerik 840d sl",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sirius act 3su1 interface module profinet",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sirius motor starter m200d profinet",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sirius soft starter 3rw44 pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sitop psu8600",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sitop ups1600 profinet",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "softnet profinet io",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "siemens",
            "version": "for pc-based windows systems firmware"
          },
          {
            "model": "simatic hmi multi panels",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic hmi mobile panels",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s120",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic hmi comfort panels",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s110 w. pn",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "sinumerik 828d",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "sinumerik 840d sl",
            "version": "*"
          },
          {
            "model": "ups1600 profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "softnet profinet io",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sitop psu8600",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sirius soft starter 3rw44 pn",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sirius act 3su1",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinumerik 840d",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinumerik 828d",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinamics sm150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sm120",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7.5"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7.4"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics gm150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics gl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics gh150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simotion",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic winac rtx",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "20100"
          },
          {
            "model": "simatic teleservice adapter standard modem",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-400",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-300",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-200 smart",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-1500",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic rf685r",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic rf680r",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic rf650r",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic et",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2000"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "443-10"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "343-10"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "16260"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "16160"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "16040"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1543-12.0.28"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1543-10"
          },
          {
            "model": "simatic cp 1542sp-1",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic cp irc",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-80"
          },
          {
            "model": "simatic cp lte eu/us",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-70"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-10"
          },
          {
            "model": "simatic cp gprs",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1242-7v20"
          },
          {
            "model": "scalance xr500",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "scalance xm400",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x4140"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x4084.0"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x4083.0"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x3000"
          },
          {
            "model": "scalance irt",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x2000"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x2000"
          },
          {
            "model": "scalance w700 series",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.4"
          },
          {
            "model": "scalance w700 series",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.5.4"
          },
          {
            "model": "scalance s615",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "scalance m-800",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.02"
          },
          {
            "model": "scalance m-800",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "ie/as-i link pn io",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "extension unit profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "22?0"
          },
          {
            "model": "extension unit profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "19?0"
          },
          {
            "model": "extension unit profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "15?0"
          },
          {
            "model": "extension unit profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "12?0"
          },
          {
            "model": "e/pb-link",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 828d",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sm120 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics sl150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gm150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gl150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gh150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic rf685r",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic rf680r",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic cp",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "16162.7"
          },
          {
            "model": "simatic cp 1604d",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2.7"
          },
          {
            "model": "simatic cp irc",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-82.1.82"
          },
          {
            "model": "simatic cp lte eu/us",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-72.1.82"
          },
          {
            "model": "simatic cp gprs",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1242-7v22.1.82"
          },
          {
            "model": "simatic rf650r",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic cp",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "443-13.2.17"
          },
          {
            "model": "simatic cp",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "15431.2.1"
          },
          {
            "model": "simatic cm1542",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1.2"
          },
          {
            "model": "scalance w700",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "6.1"
          },
          {
            "model": "extension unit profinet",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "22?1.1.1"
          },
          {
            "model": "extension unit profinet",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "19?1.1.1"
          },
          {
            "model": "extension unit profinet",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "15?1.1.1"
          },
          {
            "model": "extension unit profinet",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "12?1.1.1"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 343 1 std",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1542sp 1 irc",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1543sp 1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1543 1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic rf650r",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic rf680r",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic rf685r",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1616",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1604",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic dk 16xx pn io",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x200",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 343 1 lean",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x200 irt",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x300",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x408",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x414",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance xm400",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance xr500",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance w700",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance m 800",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance s615",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "softnet profinet io",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 343 1 adv",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ie pb link",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ie as i link pn io",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic teleservice adapter standard modem",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic teleservice adapter ie basic modem",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic teleservice adapter ie advanced modem",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sitop psu8600",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ups1600 profinet",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200al",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200ecopn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200m",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 443 1 std",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200mp",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200pro",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200s",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "pn pn coupler",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dk standard ethernet controller",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200p pn io",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200 pn io",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 200 smart",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 443 1 adv",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1200",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500 controller",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic winac rtx 2010",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sirius act 3su1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sirius soft starter 3rw44 pn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sirius motor starter m200d profinet",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simocode pro v profinet",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcm",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 443 1 opc ua",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcp",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g110m",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g120 c p d w pn",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g130",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s110 w pn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s120",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics v90 w pn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simotion",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1243 1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi comfort panels",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi multi panels",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi mobile panels",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cm 1542 1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1542sp 1",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2681"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.1.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.1.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.2.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.2.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1.82",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.0.15",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.0.15",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.0.15",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.7",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.7",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_dk-16xx_pn_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.7",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_dk-16xx_pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "5.2.2",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "5.4.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.1.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.1.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.10.2",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "14",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_standard_modem_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_standard_modem:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic_modem:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.0.2",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.0.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.1.1",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.4.0",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.2.1",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.0.6",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2010",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.1.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.4",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.2",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.4",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:4.4:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110_pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.01",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.5",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.5",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.5",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "15.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "15.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "15.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1.82",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cm_1542sp-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.0.15",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cm_1542sp-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.1.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.1.8",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-2681"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team.",
        "sources": [
          {
            "db": "BID",
            "id": "98369"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2017-2681",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 6.1,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2017-2681",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2017-06153",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "33467505-7492-4ae1-b978-12f61201709a",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "VHN-110884",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2017-2681",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2017-2681",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-06153",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201705-639",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "33467505-7492-4ae1-b978-12f61201709a",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-110884",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110884"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2681"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. SIMATIC HMI is an industrial device from Siemens AG, Germany. The SIMATIC HMI panels are used for operator control and monitoring of machines and equipment. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. \nAttackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. A vulnerability has been identified in SIMATIC CP 343-1 Std (All versions), SIMATIC CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std (All versions \u003c V3.2.17), SIMATIC CP 443-1 Adv (All versions \u003c V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions \u003c V2.1.82), SIMATIC CP 1243-1 IRC (All versions \u003c V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions \u003c V2.0), SIMATIC CM 1542SP-1 (All versions \u003c V1.0.15), SIMATIC CP 1542SP-1 IRC (All versions \u003c V1.0.15), SIMATIC CP 1543SP-1 (All versions \u003c V1.0.15), SIMATIC CP 1543-1 (All versions \u003c V2.1), SIMATIC RF650R (All versions \u003c V3.0), SIMATIC RF680R (All versions \u003c V3.0), SIMATIC RF685R (All versions \u003c V3.0), SIMATIC CP 1616 (All versions \u003c V2.7), SIMATIC CP 1604 (All versions \u003c V2.7), SIMATIC DK-16xx PN IO (All versions \u003c V2.7), SCALANCE X-200 (All versions \u003c V5.2.2), SCALANCE X-200 IRT (All versions), SCALANCE X-300/X408 (All versions \u003c V4.1.0), SCALANCE X414 (All versions \u003c V3.10.2), SCALANCE XM400 (All versions \u003c V6.1), SCALANCE XR500 (All versions \u003c V6.1), SCALANCE W700 (All versions \u003c V6.1), SCALANCE M-800, S615 (All versions \u003c V4.03), Softnet PROFINET IO for PC-based Windows systems (All versions \u003c V14 SP1), IE/PB-Link (All versions \u003c V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions \u003c V1.2.0), SITOP UPS1600 PROFINET (All versions \u003c V2.2.0), SIMATIC ET 200AL (All versions \u003c V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions \u003c V4.0.1), SIMATIC ET 200MP IM155-5 PN ST (All versions \u003c V4.1), SIMATIC ET 200MP (except IM155-5 PN BA and IM155-5 PN ST) (All versions), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions \u003c V4.1.0), SIMATIC ET 200SP (except IM155-6 PN ST) (All versions), SIMATIC PN/PN Coupler (All versions \u003c V4.0), Development/Evaluation Kit DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch04), Development/Evaluation Kit EK-ERTEC 200P (All versions \u003c V4.4.0 Patch01), Development/Evaluation Kit EK-ERTEC 200 (All versions \u003c V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions \u003c V2.3), SIMATIC S7-300 incl. F and T (All versions \u003c V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions \u003c V6.0.6), SIMATIC S7-400-H V6 (All versions \u003c V6.0.7), SIMATIC S7-400 PN/DP V7 Incl. F (All versions \u003c V7.0.2), SIMATIC S7-410 (All versions \u003c V8.2), SIMATIC S7-1200 incl. F (All versions \u003c V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions \u003c V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions \u003c V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft Starter 3RW44 PN (All versions), SIRIUS Motor Starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions \u003c V2.0.0), SINAMICS DCM w. PN (All versions \u003c V1.4 SP1 HF5), SINAMICS DCP w. PN (All versions \u003c V1.2 HF 1), SINAMICS G110M w. PN (All versions \u003c V4.7 SP6 HF3), SINAMICS G120(C/P/D) w. PN (All versions \u003c V4.7 SP6 HF3), SINAMICS G130 V4.7 w. PN (All versions \u003c V4.7 HF27), SINAMICS G150 V4.7 w. PN (V4.7: All versions \u003c V4.7 HF27), SINAMICS G130 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS G150 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS S110 w. PN (All versions \u003c V4.4 SP3 HF5), SINAMICS S120 V4.7 w. PN (All versions \u003c V4.7 HF27), and others. Siemens SIMATIC S7-300 F, etc. Siemens SIMATIC S7-300 F is a process controller. SIMATIC HMI Comfort Panels are touch screens",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-2681"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110884"
          }
        ],
        "trust": 2.7
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-2681",
            "trust": 3.6
          },
          {
            "db": "SIEMENS",
            "id": "SSA-293562",
            "trust": 2.6
          },
          {
            "db": "BID",
            "id": "98369",
            "trust": 2.0
          },
          {
            "db": "SECTRACK",
            "id": "1038463",
            "trust": 1.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-129-02",
            "trust": 1.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-639",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004135",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-18-023-02",
            "trust": 0.3
          },
          {
            "db": "SIEMENS",
            "id": "SSA-284673",
            "trust": 0.3
          },
          {
            "db": "IVD",
            "id": "33467505-7492-4AE1-B978-12F61201709A",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-110884",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110884"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2681"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ]
      },
      "id": "VAR-201705-3221",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110884"
          }
        ],
        "trust": 1.4971765550000002
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:51:14.181000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SSA-293562",
            "trust": 0.8,
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
          },
          {
            "title": "Patch for Siemens SIMATIC HMI Denial of Service Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/93365"
          },
          {
            "title": "Multiple Siemens Product security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=70109"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-400",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-20",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-110884"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2681"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
          },
          {
            "trust": 1.7,
            "url": "http://www.securityfocus.com/bid/98369"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
          },
          {
            "trust": 1.7,
            "url": "http://www.securitytracker.com/id/1038463"
          },
          {
            "trust": 1.1,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-02"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2681"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2681"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-129-02"
          },
          {
            "trust": 0.3,
            "url": "http://subscriber.communications.siemens.com/"
          },
          {
            "trust": 0.3,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-023-02"
          },
          {
            "trust": 0.3,
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110884"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2681"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110884"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2681"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-09T00:00:00",
            "db": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a"
          },
          {
            "date": "2017-05-09T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "date": "2017-05-11T00:00:00",
            "db": "VULHUB",
            "id": "VHN-110884"
          },
          {
            "date": "2017-05-08T00:00:00",
            "db": "BID",
            "id": "98369"
          },
          {
            "date": "2017-06-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "date": "2017-05-11T10:29:00.180000",
            "db": "NVD",
            "id": "CVE-2017-2681"
          },
          {
            "date": "2017-05-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-09T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          },
          {
            "date": "2020-09-29T00:00:00",
            "db": "VULHUB",
            "id": "VHN-110884"
          },
          {
            "date": "2018-05-09T14:00:00",
            "db": "BID",
            "id": "98369"
          },
          {
            "date": "2017-09-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004135"
          },
          {
            "date": "2022-04-12T18:29:19.557000",
            "db": "NVD",
            "id": "CVE-2017-2681"
          },
          {
            "date": "2022-03-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens SIMATIC HMI Denial of service vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06153"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "resource management error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-639"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201705-3220

    Vulnerability from variot - Updated: 2023-12-18 12:51

    Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. SIMATIC CP, SIMATIC RF600, SCALANCE W700, etc. are all industrial automation products from Siemens AG. A denial of service vulnerability exists in several industrial devices from Siemens. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. Attackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. SIEMENS SIMATIC CP 343-1 Std, CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std, CP 443-1 Adv (All versions before V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions before V2.1.82), SIMATIC CP 1243-1 IRC (All versions before V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions before V2.0), SIMATIC CP 1542SP-1, CP 1542SP-1 IRC, and CP 1543SP-1 (All versions before to V1.0.15), SIMATIC CP 1543-1 (All versions before V2.1), SIMATIC RF650R, RF680R, RF685R (All versions before V3.0), SIMATIC CP 1616, CP 1604, DK-16xx PN IO (All versions before V2.7), SCALANCE X-200 (All versions before V5.2.2), SCALANCE X200 IRT (All versions before V5.4.0), SCALANCE X-300/X408 (All versions before V4.1.0), SCALANCE X414 (All versions before V3.10.2), SCALANCE XM400, XR500 (All versions before V6.1), SCALANCE W700 (All versions before V6.1), SCALANCE M-800, S615 (All versions before V04.03), Softnet PROFINET IO for PC-based Windows systems (All versions before V14 SP1), IE/PB-Link (All versions before V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions before V1.2.0), SITOP UPS1600 PROFINET (All versions before V2.2.0), SIMATIC ET 200AL (All versions before V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP (All versions before V4.0.1), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP (All versions before V4.1.0), SIMATIC PN/PN Coupler (All versions before V4.0), DK Standard Ethernet Controller (All versions before V4.1.1 Patch04), EK-ERTEC 200P PN IO (All versions before V4.4.0 Patch01), EK-ERTEC 200 PN IO (All versions before V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions before V2.3), SIMATIC S7-300 incl. F and T (All versions before V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions before V6.0.6), SIMATIC S7-400-H V6 (All versions before V6.0.7), SIMATIC S7-400 PN/DP V7 incl. F (All versions), SIMATIC S7-CPU 410 (All versions before V8.2), SIMATIC S7-1200 incl. F (All versions before V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions before V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions before V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft starter 3RW44 PN (All versions), SIRIUS Motor starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions), SINAMICS DCM (All versions before V1.4 SP1 HF5), SINAMICS DCP (All versions), SINAMICS G110M / G120(C/P/D) w. PN (All versions before V4.7 SP6 HF3), SINAMICS G130 and G150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S110 w. PN (All versions before V4.4 SP1 HF5), SINAMICS S120 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS V90 w. PN (All versions before V1.1), SIMOTION (All versions before V4.5 HF1), SINUMERIK 828D (All versions before V4.5 SP6 HF2 and V4.7 before SP6 HF8), SINUMERIK 840D sl (All versions before V4.5 SP6 HF8 and V4.7 before SP4 HF1), SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet. Siemens SIMATIC S7-200 Smart, etc. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) used in small and medium-sized automation systems. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module used to support PROFINET (a new generation of automation bus standard based on industrial Ethernet technology). SIRIUS Motor starter M200D PROFINET is a motor starter. The following products and versions are affected: Siemens Extension Unit 12\" PROFINET prior to V01.01.01; Extension Unit 15\" PROFINET prior to V01.01.01; Extension Unit 19\" PROFINET prior to V01.01.01; Extension Unit 22\" PROFINET SIMATIC CP 1242-7 GPRS V2 prior to V2.1.82; SIMATIC CP 1243-7 LTE/US prior to V2.1.82; SIMATIC CP 1243-8 prior to V2.1.82; SIMATIC CP 1626 V1.1 previous version

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3220",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "simatic dk-16xx pn io",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic rf685r",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic rf650r",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic rf680r",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1543sp-1",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1542sp-1 irc",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1542sp-1",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance xr500",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance s615",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance m-800",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance xm400",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance w700",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics gm150",
            "scope": "eq",
            "trust": 1.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics gh150",
            "scope": "eq",
            "trust": 1.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic dk-1604 pn io",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.7"
          },
          {
            "model": "simatic cp 343-1 adv",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic tdc cp51m1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.1.8"
          },
          {
            "model": "simatic cp 1243-1 irc",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1.82"
          },
          {
            "model": "sinamics dcm",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.4"
          },
          {
            "model": "sinamics g120\\ w. pn",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic cp 1543-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1"
          },
          {
            "model": "sirius act 3su1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.1.0"
          },
          {
            "model": "simatic rf680r",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic cp 1543sp-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.0.15"
          },
          {
            "model": "simatic et 200al",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.0.2"
          },
          {
            "model": "simatic cp 443-1 adv",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.2.17"
          },
          {
            "model": "scalance x414",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.10.2"
          },
          {
            "model": "sinumerik 828d",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "sinamics gl150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "softnet profinet io",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14"
          },
          {
            "model": "simatic et 200pro",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "ek-ertec 200 pn io",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.1"
          },
          {
            "model": "simatic cp 1243-1 dnp3",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "scalance x300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.0"
          },
          {
            "model": "scalance s615",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.03"
          },
          {
            "model": "sinamics s110 pn",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4"
          },
          {
            "model": "simatic s7-400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.0.6"
          },
          {
            "model": "simatic et 200m",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "ups1600 profinet",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.2.0"
          },
          {
            "model": "sinamics dcp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.2"
          },
          {
            "model": "simotion",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "sinamics gm150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics dcm",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.4"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.1"
          },
          {
            "model": "sinamics s120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics g110m",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic cp 1242-7 gprs",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1.82"
          },
          {
            "model": "sinamics g130",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic cp 1542sp-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.0.15"
          },
          {
            "model": "extension unit 22 profinet",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "01.01.01"
          },
          {
            "model": "scalance xr500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.1"
          },
          {
            "model": "simatic s7-200 smart",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.3"
          },
          {
            "model": "simatic et 200s",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic cp 1243-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1.82"
          },
          {
            "model": "sinamics sm120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "ek-ertec 200p pn io",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4.0"
          },
          {
            "model": "simatic tdc cpu555",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.1.1"
          },
          {
            "model": "sinamics s110 pn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4"
          },
          {
            "model": "simatic cp 1616",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.7"
          },
          {
            "model": "sinamics s120",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics g150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "scalance w700",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.1"
          },
          {
            "model": "sinamics gl150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics g110m",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sirius motor starter m200d profinet",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "softnet profinet io",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "14"
          },
          {
            "model": "sinamics g130",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic cp 1243-7 lte\\/us",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1.82"
          },
          {
            "model": "simatic et 200sp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.0"
          },
          {
            "model": "scalance xm400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "6.1"
          },
          {
            "model": "sirius soft starter 3rw44 pn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic hmi multi panels",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "15.1"
          },
          {
            "model": "simatic winac rtx",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "simocode pro v profinet",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0.0"
          },
          {
            "model": "sinamics gh150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic hmi mobile panels",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "15.1"
          },
          {
            "model": "simatic rf650r",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic teleservice adapter ie basic",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "ek-ertec 200 pn io",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.1"
          },
          {
            "model": "sinamics s150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic cp 1243-8",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1.82"
          },
          {
            "model": "sinamics g150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sl150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics sm120",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic cp 1626",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.1"
          },
          {
            "model": "simatic cp 343-1 lean",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.1.3"
          },
          {
            "model": "ie\\/pb-link",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "scalance x200 irt",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.4.0"
          },
          {
            "model": "pn\\/pn coupler",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.0"
          },
          {
            "model": "simatic cp 1604",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.7"
          },
          {
            "model": "simatic et 200ecopn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "ek-ertec 200p pn io",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.4.0"
          },
          {
            "model": "ie\\/as-i link pn io",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic rf685r",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "sinumerik 828d",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "sinamics g120\\ w. pn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics v90 pn",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.01"
          },
          {
            "model": "extension unit 19 profinet",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "01.01.01"
          },
          {
            "model": "simatic cp 443-1 std",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.2.17"
          },
          {
            "model": "simatic teleservice adapter ie standard",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics s150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic s7-300",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "extension unit 15 profinet",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "01.01.01"
          },
          {
            "model": "simatic s7-1500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1"
          },
          {
            "model": "simatic cp 1243-1 iec",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic dk-1616 pn io",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.7"
          },
          {
            "model": "scalance x200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2.2"
          },
          {
            "model": "simatic s7-1200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.2.1"
          },
          {
            "model": "simatic cp 443-1 opc-ua",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "simatic hmi comfort panels",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "15.1"
          },
          {
            "model": "scalance m-800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.03"
          },
          {
            "model": "simatic cp 343-1 std",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.1.3"
          },
          {
            "model": "simotion",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5"
          },
          {
            "model": "sinamics dcp",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.2"
          },
          {
            "model": "scalance x408",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.0"
          },
          {
            "model": "extension unit 12 profinet",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "01.01.01"
          },
          {
            "model": "simatic s7-1500 software controller",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.1"
          },
          {
            "model": "sitop psu8600",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.2.0"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.1"
          },
          {
            "model": "simatic cp 1542sp-1 irc",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.0.15"
          },
          {
            "model": "simatic et 200mp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.0.1"
          },
          {
            "model": "simatic teleservice adapter ie advanced",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic cm 1542-1",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.0"
          },
          {
            "model": "simatic winac rtx",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200 pn io",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200p pn io",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ie/as-i link pn io",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ie/pb-link",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "pn/pn coupler",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x200 irt",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x200",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x300",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x408",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x414",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cm 1542-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1243-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1543-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1604",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1616",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 343-1 adv",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 343-1 lean",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 343-1 std",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 443-1 adv",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 443-1 opc-ua",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 443-1 std",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200al",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200ecopn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200m",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200mp",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200pro",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200s",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200sp",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic hmi comfort panels",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic hmi mobile panels",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic hmi multi panels",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1200",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1500 software controller",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-1500",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-200 smart",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-300",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic teleservice adapter ie advanced",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic teleservice adapter ie basic",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic teleservice adapter standard modem",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic winac rtx 2010",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simocode pro v profinet",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simotion",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcm",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcp",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g110m",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g120 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g130",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics g150",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s110 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s120",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s150",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics v90 w. pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinumerik 828d",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinumerik 840d sl",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sirius act 3su1 interface module profinet",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sirius motor starter m200d profinet",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sirius soft starter 3rw44 pn",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sitop psu8600",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sitop ups1600 profinet",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "softnet profinet io",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "siemens",
            "version": "for pc-based windows systems firmware"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "1616"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "1604"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "1543-1"
          },
          {
            "model": "simatic cm",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "1542-1"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "1243-1"
          },
          {
            "model": "simatic cp opc-ua",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "443-1"
          },
          {
            "model": "simatic cp adv",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "443-1"
          },
          {
            "model": "simatic cp std",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "443-1"
          },
          {
            "model": "simatic cp std",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "343-1"
          },
          {
            "model": "simatic cp lean",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "343-1"
          },
          {
            "model": "simatic cp adv",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "343-1"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "x408"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "x414"
          },
          {
            "model": "scalance irt",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "x200"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "x200"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "x300"
          },
          {
            "model": "simatic rf650r",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 443-1 opc-ua",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cm 1542-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1542sp-1 irc",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 443-1 adv",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 343-1 std",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1543-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1543sp-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic cp 1542sp-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic rf680r",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "sinumerik 828d",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "sinumerik 840d sl",
            "version": "*"
          },
          {
            "model": "ups1600 profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "softnet profinet io",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sitop psu8600",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sirius soft starter 3rw44 pn",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sirius act 3su1",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinumerik 840d",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinumerik 828d",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinamics sm150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sm120",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7.5"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7.4"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics gl150",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simotion",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic winac rtx",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "20100"
          },
          {
            "model": "simatic teleservice adapter standard modem",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-400",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-300",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-200 smart",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic s7-1500",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic rf685r",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic rf680r",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic rf650r",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic et",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2000"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "443-10"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "343-10"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "16260"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "16160"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "16040"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1543-12.0.28"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1543-10"
          },
          {
            "model": "simatic cp 1542sp-1",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "simatic cp irc",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-80"
          },
          {
            "model": "simatic cp lte eu/us",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-70"
          },
          {
            "model": "simatic cp",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-10"
          },
          {
            "model": "simatic cp gprs",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1242-7v20"
          },
          {
            "model": "scalance xr500",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "scalance xm400",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x4140"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x4084.0"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x4083.0"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x3000"
          },
          {
            "model": "scalance irt",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x2000"
          },
          {
            "model": "scalance",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "x2000"
          },
          {
            "model": "scalance w700 series",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.4"
          },
          {
            "model": "scalance w700 series",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.5.4"
          },
          {
            "model": "scalance s615",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "scalance m-800",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.02"
          },
          {
            "model": "scalance m-800",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "ie/as-i link pn io",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "extension unit profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "22?0"
          },
          {
            "model": "extension unit profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "19?0"
          },
          {
            "model": "extension unit profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "15?0"
          },
          {
            "model": "extension unit profinet",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "12?0"
          },
          {
            "model": "e/pb-link",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "0"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 828d",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics sm120 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics sl150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gm150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gl150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gh150 sp2",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic rf685r",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic rf680r",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic cp",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "16162.7"
          },
          {
            "model": "simatic cp 1604d",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "2.7"
          },
          {
            "model": "simatic cp irc",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-82.1.82"
          },
          {
            "model": "simatic cp lte eu/us",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1243-72.1.82"
          },
          {
            "model": "simatic cp gprs",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1242-7v22.1.82"
          },
          {
            "model": "simatic rf650r",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "3.0"
          },
          {
            "model": "simatic cp",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "443-13.2.17"
          },
          {
            "model": "simatic cp",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "15431.2.1"
          },
          {
            "model": "simatic cm1542",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "1.2"
          },
          {
            "model": "scalance w700",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "6.1"
          },
          {
            "model": "extension unit profinet",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "22?1.1.1"
          },
          {
            "model": "extension unit profinet",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "19?1.1.1"
          },
          {
            "model": "extension unit profinet",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "15?1.1.1"
          },
          {
            "model": "extension unit profinet",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "siemens",
            "version": "12?1.1.1"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 343 1 std",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1542sp 1 irc",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1543sp 1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1543 1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic rf650r",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic rf680r",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic rf685r",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1616",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1604",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic dk 16xx pn io",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x200",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 343 1 lean",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x200 irt",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x300",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x408",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x414",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance xm400",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance xr500",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance w700",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance m 800",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance s615",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "softnet profinet io",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 343 1 adv",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ie pb link",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ie as i link pn io",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic teleservice adapter standard modem",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic teleservice adapter ie basic modem",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic teleservice adapter ie advanced modem",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sitop psu8600",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ups1600 profinet",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200al",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200ecopn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200m",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 443 1 std",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200mp",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200pro",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200s",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200sp",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "pn pn coupler",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dk standard ethernet controller",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200p pn io",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200 pn io",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 200 smart",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 443 1 adv",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1200",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 1500 controller",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic winac rtx 2010",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sirius act 3su1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sirius soft starter 3rw44 pn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sirius motor starter m200d profinet",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simocode pro v profinet",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcm",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 443 1 opc ua",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcp",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g110m",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g120 c p d w pn",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g130",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s110 w pn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s120",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics v90 w pn",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simotion",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1243 1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi comfort panels",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi multi panels",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic hmi mobile panels",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cm 1542 1",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic cp 1542sp 1",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2680"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.1.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.1.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.2.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.2.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1.82",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.0.15",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.0.15",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.0.15",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.7",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.7",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.7",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_dk-1616_pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "5.2.2",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "5.4.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.1.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.1.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.10.2",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "14",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.2.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.0.2",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.0.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.1.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.1.1",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.4.0",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.2.1",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "6.0.6",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2010",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.1.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.0.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.4",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:sp1:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.2",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.4",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:4.4:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:_s110_pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.01",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.5",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.5",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.5",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "15.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "15.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "15.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1.82",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_dk-1604_pn_io_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.7",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_dk-1604_pn_io:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.1.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.1.8",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:extension_unit_12_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "01.01.01",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:extension_unit_12_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:extension_unit_15_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "01.01.01",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:extension_unit_15_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:extension_unit_19_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "01.01.01",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:extension_unit_19_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:extension_unit_22_profinet_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "01.01.01",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:extension_unit_22_profinet:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1.82",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte\\/us_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1.82",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte\\/us:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-8_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.1.82",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-8:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-2680"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team.",
        "sources": [
          {
            "db": "BID",
            "id": "98369"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2017-2680",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 6.1,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2017-2680",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2017-06151",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.5,
                "id": "VHN-110883",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.8,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2017-2680",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2017-2680",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-06151",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201705-574",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4",
                "trust": 0.2,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-110883",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110883"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2680"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. SIMATIC CP, SIMATIC RF600, SCALANCE W700, etc. are all industrial automation products from Siemens AG. A denial of service vulnerability exists in several industrial devices from Siemens. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. \nAttackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. SIEMENS SIMATIC CP 343-1 Std, CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std, CP 443-1 Adv (All versions before V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions before V2.1.82), SIMATIC CP 1243-1 IRC (All versions before V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions before V2.0), SIMATIC CP 1542SP-1, CP 1542SP-1 IRC, and CP 1543SP-1 (All versions before to V1.0.15), SIMATIC CP 1543-1 (All versions before V2.1), SIMATIC RF650R, RF680R, RF685R (All versions before V3.0), SIMATIC CP 1616, CP 1604, DK-16xx PN IO (All versions before V2.7), SCALANCE X-200 (All versions before V5.2.2), SCALANCE X200 IRT (All versions before V5.4.0), SCALANCE X-300/X408 (All versions before V4.1.0), SCALANCE X414 (All versions before V3.10.2), SCALANCE XM400, XR500 (All versions before V6.1), SCALANCE W700 (All versions before V6.1), SCALANCE M-800, S615 (All versions before V04.03), Softnet PROFINET IO for PC-based Windows systems (All versions before V14 SP1), IE/PB-Link (All versions before V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions before V1.2.0), SITOP UPS1600 PROFINET (All versions before V2.2.0), SIMATIC ET 200AL (All versions before V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP (All versions before V4.0.1), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP (All versions before V4.1.0), SIMATIC PN/PN Coupler (All versions before V4.0), DK Standard Ethernet Controller (All versions before V4.1.1 Patch04), EK-ERTEC 200P PN IO (All versions before V4.4.0 Patch01), EK-ERTEC 200 PN IO (All versions before V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions before V2.3), SIMATIC S7-300 incl. F and T (All versions before V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions before V6.0.6), SIMATIC S7-400-H V6 (All versions before V6.0.7), SIMATIC S7-400 PN/DP V7 incl. F (All versions), SIMATIC S7-CPU 410 (All versions before V8.2), SIMATIC S7-1200 incl. F (All versions before V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions before V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions before V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft starter 3RW44 PN (All versions), SIRIUS Motor starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions), SINAMICS DCM (All versions before V1.4 SP1 HF5), SINAMICS DCP (All versions), SINAMICS G110M / G120(C/P/D) w. PN (All versions before V4.7 SP6 HF3), SINAMICS G130 and G150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S110 w. PN (All versions before V4.4 SP1 HF5), SINAMICS S120 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS V90 w. PN (All versions before V1.1), SIMOTION (All versions before V4.5 HF1), SINUMERIK 828D (All versions before V4.5 SP6 HF2 and V4.7 before SP6 HF8), SINUMERIK 840D sl (All versions before V4.5 SP6 HF8 and V4.7 before SP4 HF1), SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet. Siemens SIMATIC S7-200 Smart, etc. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) used in small and medium-sized automation systems. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module used to support PROFINET (a new generation of automation bus standard based on industrial Ethernet technology). SIRIUS Motor starter M200D PROFINET is a motor starter. The following products and versions are affected: Siemens Extension Unit 12\\\" PROFINET prior to V01.01.01; Extension Unit 15\\\" PROFINET prior to V01.01.01; Extension Unit 19\\\" PROFINET prior to V01.01.01; Extension Unit 22\\\" PROFINET SIMATIC CP 1242-7 GPRS V2 prior to V2.1.82; SIMATIC CP 1243-7 LTE/US prior to V2.1.82; SIMATIC CP 1243-8 prior to V2.1.82; SIMATIC CP 1626 V1.1 previous version",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-2680"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110883"
          }
        ],
        "trust": 2.7
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-2680",
            "trust": 3.6
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-18-023-02",
            "trust": 2.8
          },
          {
            "db": "SIEMENS",
            "id": "SSA-293562",
            "trust": 2.6
          },
          {
            "db": "SIEMENS",
            "id": "SSA-284673",
            "trust": 2.0
          },
          {
            "db": "BID",
            "id": "98369",
            "trust": 2.0
          },
          {
            "db": "SIEMENS",
            "id": "SSA-546832",
            "trust": 1.7
          },
          {
            "db": "SECTRACK",
            "id": "1038463",
            "trust": 1.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-129-02",
            "trust": 1.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-574",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151",
            "trust": 0.8
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-18-128-01",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "296C9514-B30D-4FA5-BCDC-9D8B2E9620C4",
            "trust": 0.2
          },
          {
            "db": "SEEBUG",
            "id": "SSVID-99023",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-110883",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110883"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2680"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ]
      },
      "id": "VAR-201705-3220",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110883"
          }
        ],
        "trust": 1.5351787667924528
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:51:14.128000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SSA-293562",
            "trust": 0.8,
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
          },
          {
            "title": "Patch for a number of Siemens products with a denial of service vulnerability (CNVD-2017-06151)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/93364"
          },
          {
            "title": "Multiple Siemens Product security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=70052"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-400",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-20",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-110883"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2680"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.8,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-023-02"
          },
          {
            "trust": 2.0,
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
          },
          {
            "trust": 1.7,
            "url": "http://www.securityfocus.com/bid/98369"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
          },
          {
            "trust": 1.7,
            "url": "http://www.securitytracker.com/id/1038463"
          },
          {
            "trust": 1.1,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-02"
          },
          {
            "trust": 0.9,
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2680"
          },
          {
            "trust": 0.8,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-128-01"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2680"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-129-02"
          },
          {
            "trust": 0.3,
            "url": "http://subscriber.communications.siemens.com/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110883"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2680"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "db": "VULHUB",
            "id": "VHN-110883"
          },
          {
            "db": "BID",
            "id": "98369"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-2680"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-09T00:00:00",
            "db": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
          },
          {
            "date": "2017-05-09T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "date": "2017-05-11T00:00:00",
            "db": "VULHUB",
            "id": "VHN-110883"
          },
          {
            "date": "2017-05-08T00:00:00",
            "db": "BID",
            "id": "98369"
          },
          {
            "date": "2017-06-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "date": "2017-05-11T01:29:05.400000",
            "db": "NVD",
            "id": "CVE-2017-2680"
          },
          {
            "date": "2017-05-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-05-09T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-06151"
          },
          {
            "date": "2020-09-29T00:00:00",
            "db": "VULHUB",
            "id": "VHN-110883"
          },
          {
            "date": "2018-05-09T14:00:00",
            "db": "BID",
            "id": "98369"
          },
          {
            "date": "2018-05-10T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          },
          {
            "date": "2022-04-12T18:29:01.937000",
            "db": "NVD",
            "id": "CVE-2017-2680"
          },
          {
            "date": "2022-02-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Siemens Service disruption in products  (DoS) Vulnerabilities",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-004134"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "resource management error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201705-574"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201910-1596

    Vulnerability from variot - Updated: 2023-12-18 12:43

    A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. Multiple Siemens products are vulnerable to resource exhaustion.Service operation interruption (DoS) There is a possibility of being put into a state. The Siemens SIMATIC S7-300 CPU is a modular universal controller for the manufacturing industry from Siemens. The products in the Siemens SIMATIC S7-400 CPU family have been designed for process control in industrial environments. SIMATIC WinAC RTX (F) 2010 is a simatic software controller for PC-based automation solutions. Siemens SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs).

    A denial of service vulnerability exists in several Siemens products. A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT (All versions < V5.2.1), SIMATIC ET 200M (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (All versions), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. Siemens CP1616, etc. are all products of Siemens (Siemens) in Germany. CP1616 is a communications processor. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. SCALANCE X-200IRT is an industrial Ethernet switch. The following products and versions are affected: Siemens SIMATIC NET CP 1616 before V2.8; SINUMERIK 840D sl (all versions); SCALANCE X-200IRT series (including SIPLUS NET variants) before V5.2.1; SIMATIC ET200S (including SIPLUS variants) (full version) etc

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201910-1596",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "simatic et 200m",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200s",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200ecopn",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic pn/pn coupler 6es7158-3ad01-0xa0",
            "scope": null,
            "trust": 1.4,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 1.0,
            "vendor": "sinumerik 828d",
            "version": "4.8"
          },
          {
            "model": "simatic s7-300 cpu",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "simatic s7-300 cpu 314",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinamics gl150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics g110m",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "ek-ertec 200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5.0"
          },
          {
            "model": "sinamics g130",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 828d",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics g120",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics gh150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic winac rtx \\",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "sinamics s150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic s7-300 cpu 315-2 dp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "simatic s7-300 cpu 312 ifm",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "simatic s7-300 cpu 315",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinamics s110",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics dcp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.3"
          },
          {
            "model": "simatic s7-300 cpu 314 ifm",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinumerik 840d sl",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-300 cpu 318-2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "cp1604",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.8"
          },
          {
            "model": "ek-ertec 200",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5.0"
          },
          {
            "model": "sinamics gl150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics gm150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic et 200ecopn",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics dcm",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.5"
          },
          {
            "model": "ek-ertec 200p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.5.0"
          },
          {
            "model": "simatic s7-300 cpu 313",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinamics sm120",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "cp1616",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2.8"
          },
          {
            "model": "simotion",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics sl150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinumerik 828d",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic s7-400 dp v7",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic et 200m",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic s7-400 pn v7",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "simatic winac rtx \\",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.1"
          },
          {
            "model": "sinamics s120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic pn\\/pn coupler 6es7158-3ad01-0xa0",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics g110m",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics g130",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "simatic et 200s",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "sinamics gm150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics g150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "simatic s7-400 v6",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "*"
          },
          {
            "model": "dk standard ethernet controller",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.1.1"
          },
          {
            "model": "simatic s7-300 cpu 316-2 dp",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "3.3.17"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "scalance x-200irt",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "5.2.1"
          },
          {
            "model": "sinamics g120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics s120",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.7"
          },
          {
            "model": "sinamics gh150",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "4.8"
          },
          {
            "model": "sinamics dcm",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "siemens",
            "version": "1.5"
          },
          {
            "model": "cp1604",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "cp1616",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "dk standard ethernet controller",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "ek-ertec 200p p",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "scalance x-200irt",
            "scope": null,
            "trust": 0.8,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic et 200pro",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics dcp",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinumerik 840d sl",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "cp1604",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2.8"
          },
          {
            "model": "cp1616",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v2.8"
          },
          {
            "model": "dk standard ethernet controller patch",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.1.105"
          },
          {
            "model": "ek-ertec 200p patch",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.5.001"
          },
          {
            "model": "ek-ertec 200p",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.5.0"
          },
          {
            "model": "scalance x-200irt",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v5.2.1"
          },
          {
            "model": "simatic s7-300 cpu family",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "simatic s7-400 and below",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v6"
          },
          {
            "model": "simatic winac rtx",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "2010"
          },
          {
            "model": "simatic s7-400 pn/dp",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v7"
          },
          {
            "model": "sinamics dcm hf1",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v1.5"
          },
          {
            "model": "sinumerik 828d sp5",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.8"
          },
          {
            "model": "sinamics g110m sp10 hf5",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7\u003cv4.7"
          },
          {
            "model": "sinamics g120 sp10 hf5",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7\u003cv4.7"
          },
          {
            "model": "sinamics g130 hf29",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7\u003cv4.7"
          },
          {
            "model": "sinamics g150",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.8"
          },
          {
            "model": "sinamics gh150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics gl150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics gm150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics s110",
            "scope": null,
            "trust": 0.6,
            "vendor": "siemens",
            "version": null
          },
          {
            "model": "sinamics s120 hf34",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7\u003cv4.7"
          },
          {
            "model": "sinamics s150",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.8"
          },
          {
            "model": "sinamics sl150",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": "sinamics sm120",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "siemens",
            "version": "v4.7"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.4,
            "vendor": "dk standard ethernet controller",
            "version": "4.1.1"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "cp1604",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic pn pn coupler 6es7158 3ad01 0xa0",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 312 ifm",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 313",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 314",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 314 ifm",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 315",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 315 2 dp",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 316 2 dp",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 300 cpu 318 2",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "cp1616",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400 v6",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400 pn v7",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic s7 400 dp v7",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic winac rtx f 2010",
            "version": null
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simotion",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcm",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcm",
            "version": "1.5"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics dcp",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g110m",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g110m",
            "version": "4.7"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g120",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g120",
            "version": "4.7"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g130",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g130",
            "version": "4.7"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "dk standard ethernet controller",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics g150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics gh150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics gl150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics gm150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s110",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s120",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s120",
            "version": "4.7"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics s150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics sl150",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinamics sm120",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinumerik 828d",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200",
            "version": "4.5.0"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sinumerik 840d sl",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "ek ertec 200p",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "scalance x 200irt",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200m",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200s",
            "version": "*"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "simatic et 200ecopn",
            "version": "*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10923"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.8",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.8",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.1.1",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:p4:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.5.0",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_firmware:4.5.0:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.5.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "5.2.1",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "3.3.17",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2010",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:sp1:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:sp2:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\):-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.5",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.8",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "4.7",
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-10923"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Siemens reported this vulnerability to CISA. Artem Zinenko of Kaspersky reported to Siemens that SIPLUS is also affected.",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-565"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2019-10923",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 5.0,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2019-10923",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-41280",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "VHN-142518",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2019-10923",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-10923",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "productcert@siemens.com",
                "id": "CVE-2019-10923",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-41280",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201910-565",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5",
                "trust": 0.2,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-142518",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10923"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10923"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-565"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A vulnerability has been identified in  SIMATIC S7-400 CPU 414-3 PN/DP V7,  SIMATIC S7-400 CPU 414F-3 PN/DP V7,  SIMATIC S7-400 CPU 416-3 PN/DP V7,  SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. Multiple Siemens products are vulnerable to resource exhaustion.Service operation interruption (DoS) There is a possibility of being put into a state. The Siemens SIMATIC S7-300 CPU is a modular universal controller for the manufacturing industry from Siemens. The products in the Siemens SIMATIC S7-400 CPU family have been designed for process control in industrial environments. SIMATIC WinAC RTX (F) 2010 is a simatic software controller for PC-based automation solutions. Siemens SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs). \n\nA denial of service vulnerability exists in several Siemens products. A vulnerability has been identified in CP1604 (All versions \u003c V2.8), CP1616 (All versions \u003c V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions \u003c V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions \u003c V4.5.0), SCALANCE X-200IRT (All versions \u003c V5.2.1), SIMATIC ET 200M (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET 200pro (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (All versions), SIMATIC S7-300 CPU family (incl. F) (All versions), SIMATIC S7-400 (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. Siemens CP1616, etc. are all products of Siemens (Siemens) in Germany. CP1616 is a communications processor. SINUMERIK 840D sl is a set of advanced machine tool numerical control system. SCALANCE X-200IRT is an industrial Ethernet switch. The following products and versions are affected: Siemens SIMATIC NET CP 1616 before V2.8; SINUMERIK 840D sl (all versions); SCALANCE X-200IRT series (including SIPLUS NET variants) before V5.2.1; SIMATIC ET200S (including SIPLUS variants) (full version) etc",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-10923"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "db": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142518"
          }
        ],
        "trust": 2.43
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-10923",
            "trust": 3.3
          },
          {
            "db": "SIEMENS",
            "id": "SSA-349422",
            "trust": 2.3
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-19-283-01",
            "trust": 1.4
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-565",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610",
            "trust": 0.8
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2019.3812",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2019.3812.2",
            "trust": 0.6
          },
          {
            "db": "IVD",
            "id": "B7DE1C6D-2642-4DF7-860F-BFE6735515F5",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-142518",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10923"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-565"
          }
        ]
      },
      "id": "VAR-201910-1596",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142518"
          }
        ],
        "trust": 1.6264974596969697
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:43:15.593000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SSA-349422",
            "trust": 0.8,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
          },
          {
            "title": "Patch for Multiple Siemens Product Denial of Service Vulnerabilities (CNVD-2019-41280)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/184335"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-400",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-142518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10923"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-283-01"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10923"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10923"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2019.3812/"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2019.3812.2/"
          },
          {
            "trust": 0.6,
            "url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-irt-30559"
          },
          {
            "trust": 0.6,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-283-01"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10923"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-565"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "db": "VULHUB",
            "id": "VHN-142518"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10923"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-565"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-11-19T00:00:00",
            "db": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
          },
          {
            "date": "2019-10-11T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "date": "2019-10-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-142518"
          },
          {
            "date": "2019-10-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          },
          {
            "date": "2019-10-10T14:15:14.503000",
            "db": "NVD",
            "id": "CVE-2019-10923"
          },
          {
            "date": "2019-10-09T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201910-565"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-11-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-41280"
          },
          {
            "date": "2023-01-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-142518"
          },
          {
            "date": "2019-10-17T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          },
          {
            "date": "2023-05-09T13:15:12.763000",
            "db": "NVD",
            "id": "CVE-2019-10923"
          },
          {
            "date": "2023-05-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201910-565"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-565"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vulnerability related to resource depletion in multiple Siemens products",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-010610"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Resource management error",
        "sources": [
          {
            "db": "IVD",
            "id": "b7de1c6d-2642-4df7-860f-bfe6735515f5"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201910-565"
          }
        ],
        "trust": 0.8
      }
    }

    CVE-2022-25622 (GCVE-0-2022-25622)

    Vulnerability from nvd – Published: 2022-04-12 00:00 – Updated: 2025-04-21 13:54
    VLAI
    Summary
    The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CFU DIQ Affected: 0 , < V2.0.0 (custom)
    Create a notification for this product.
    Siemens SIMATIC CFU PA Affected: 0 , < V2.0.0 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200AL IM 157-1 PN Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC ET 200MP IM 155-5 PN HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 MF HF Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 PN HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 PN/3 HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DI 16x24VDC, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DI 8x24VDC, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L Affected: V5.1.1 , < V5.1.3 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC PN/MF Coupler Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC PN/PN Coupler Affected: All versions >= 4.2
    Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.0.0
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 412-2 PN V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Affected: 0 , < V6.0.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) Affected: All versions < V10.1.1
    Create a notification for this product.
    Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) Affected: 0 , < V8.2.3 (custom)
    Create a notification for this product.
    Siemens SIMATIC TDC CP51M1 Affected: 0 , < V1.1.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC TDC CPU555 Affected: 0 , < V1.2.1 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinAC RTX 2010 Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC WinAC RTX F 2010 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS DCM Affected: 0 , < V1.5 SP1 (custom)
    Create a notification for this product.
    Siemens SINAMICS G110M Affected: 0 , < V4.7.14 (custom)
    Create a notification for this product.
    Siemens SINAMICS G115D Affected: 0 , < V4.7.14 (custom)
    Create a notification for this product.
    Siemens SINAMICS G120 (incl. SIPLUS variants) Affected: 0 , < V4.7 SP14 (custom)
    Create a notification for this product.
    Siemens SINAMICS G130 Affected: 0 , < V5.2.3.13 (custom)
    Create a notification for this product.
    Siemens SINAMICS G150 Affected: 0 , < V5.2.3.13 (custom)
    Create a notification for this product.
    Siemens SINAMICS S110 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINAMICS S120 (incl. SIPLUS variants) Affected: 0 , < V5.2 SP3 HF13 (custom)
    Create a notification for this product.
    Siemens SINAMICS S150 Affected: 0 , < V5.2.3.13 (custom)
    Create a notification for this product.
    Siemens SINAMICS S210 (6SL5...) Affected: 0 , < V5.2 SP3 HF18 (custom)
    Create a notification for this product.
    Siemens SINAMICS V90 Affected: 0 , < V1.04.04 (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200MP IM 155-5 PN HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS ET 200SP IM 155-6 PN HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200SP IM 155-6 PN HF TX RAIL Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS HCS4200 CIM4210 Affected: All versions
    Create a notification for this product.
    Siemens SIPLUS HCS4200 CIM4210C Affected: All versions
    Create a notification for this product.
    Siemens SIPLUS HCS4300 CIM4310 Affected: All versions
    Create a notification for this product.
    Siemens SIPLUS NET PN/PN Coupler Affected: All versions >= 4.2
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.19
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:42:50.341Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-25622",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-18T15:12:29.985401Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-21T13:54:36.799Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CFU DIQ",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CFU PA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200AL IM 157-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200MP IM 155-5 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 MF HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.3",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PN/MF Coupler",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PN/PN Coupler",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= 4.2"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.0.0"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 412-2 PN V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V10.1.1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.2.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC TDC CP51M1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.1.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC TDC CPU555",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.2.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinAC RTX 2010",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinAC RTX F 2010",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS DCM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.5 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G110M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.7.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G115D",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.7.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.7 SP14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G130",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2.3.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G150",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2.3.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S110",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2 SP3 HF13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S150",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2.3.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S210 (6SL5...)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2 SP3 HF18",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS V90",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.04.04",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200MP IM 155-5 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200MP IM 155-5 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS HCS4200 CIM4210",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS HCS4200 CIM4210C",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS HCS4300 CIM4310",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET PN/PN Coupler",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= 4.2"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:26:55.984Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-25622",
        "datePublished": "2022-04-12T00:00:00.000Z",
        "dateReserved": "2022-02-21T00:00:00.000Z",
        "dateUpdated": "2025-04-21T13:54:36.799Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-25622 (GCVE-0-2022-25622)

    Vulnerability from cvelistv5 – Published: 2022-04-12 00:00 – Updated: 2025-04-21 13:54
    VLAI
    Summary
    The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    Siemens SIMATIC CFU DIQ Affected: 0 , < V2.0.0 (custom)
    Create a notification for this product.
    Siemens SIMATIC CFU PA Affected: 0 , < V2.0.0 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200AL IM 157-1 PN Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC ET 200MP IM 155-5 PN HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 MF HF Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 PN HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET 200SP IM 155-6 PN/3 HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DI 16x24VDC, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DI 8x24VDC, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L Affected: V5.1.1 , < V5.1.3 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L Affected: V5.1.1 , < V5.1.2 (custom)
    Create a notification for this product.
    Siemens SIMATIC PN/MF Coupler Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC PN/PN Coupler Affected: All versions >= 4.2
    Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.0.0
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 412-2 PN V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Affected: 0 , < V6.0.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) Affected: All versions < V10.1.1
    Create a notification for this product.
    Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) Affected: 0 , < V8.2.3 (custom)
    Create a notification for this product.
    Siemens SIMATIC TDC CP51M1 Affected: 0 , < V1.1.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC TDC CPU555 Affected: 0 , < V1.2.1 (custom)
    Create a notification for this product.
    Siemens SIMATIC WinAC RTX 2010 Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC WinAC RTX F 2010 Affected: All versions
    Create a notification for this product.
    Siemens SINAMICS DCM Affected: 0 , < V1.5 SP1 (custom)
    Create a notification for this product.
    Siemens SINAMICS G110M Affected: 0 , < V4.7.14 (custom)
    Create a notification for this product.
    Siemens SINAMICS G115D Affected: 0 , < V4.7.14 (custom)
    Create a notification for this product.
    Siemens SINAMICS G120 (incl. SIPLUS variants) Affected: 0 , < V4.7 SP14 (custom)
    Create a notification for this product.
    Siemens SINAMICS G130 Affected: 0 , < V5.2.3.13 (custom)
    Create a notification for this product.
    Siemens SINAMICS G150 Affected: 0 , < V5.2.3.13 (custom)
    Create a notification for this product.
    Siemens SINAMICS S110 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SINAMICS S120 (incl. SIPLUS variants) Affected: 0 , < V5.2 SP3 HF13 (custom)
    Create a notification for this product.
    Siemens SINAMICS S150 Affected: 0 , < V5.2.3.13 (custom)
    Create a notification for this product.
    Siemens SINAMICS S210 (6SL5...) Affected: 0 , < V5.2 SP3 HF18 (custom)
    Create a notification for this product.
    Siemens SINAMICS V90 Affected: 0 , < V1.04.04 (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200MP IM 155-5 PN HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS ET 200SP IM 155-6 PN HF Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS ET 200SP IM 155-6 PN HF TX RAIL Affected: V4.2.0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS HCS4200 CIM4210 Affected: All versions
    Create a notification for this product.
    Siemens SIPLUS HCS4200 CIM4210C Affected: All versions
    Create a notification for this product.
    Siemens SIPLUS HCS4300 CIM4310 Affected: All versions
    Create a notification for this product.
    Siemens SIPLUS NET PN/PN Coupler Affected: All versions >= 4.2
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.19
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.19
    Create a notification for this product.
    Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 Affected: 0 , < * (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:42:50.341Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-25622",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-18T15:12:29.985401Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-21T13:54:36.799Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CFU DIQ",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CFU PA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200AL IM 157-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200MP IM 155-5 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 MF HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.3",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.1.2",
                  "status": "affected",
                  "version": "V5.1.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PN/MF Coupler",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PN/PN Coupler",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= 4.2"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.0.0"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 412-2 PN V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V10.1.1"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.2.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC TDC CP51M1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.1.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC TDC CPU555",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.2.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinAC RTX 2010",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinAC RTX F 2010",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS DCM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.5 SP1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G110M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.7.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G115D",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.7.14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.7 SP14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G130",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2.3.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS G150",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2.3.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S110",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2 SP3 HF13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S150",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2.3.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S210 (6SL5...)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.2 SP3 HF18",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS V90",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.04.04",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200MP IM 155-5 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200MP IM 155-5 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V4.2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS HCS4200 CIM4210",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS HCS4200 CIM4210C",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS HCS4300 CIM4310",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET PN/PN Coupler",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= 4.2"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.3.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V3.2.19"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400: Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-14T10:26:55.984Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-25622",
        "datePublished": "2022-04-12T00:00:00.000Z",
        "dateReserved": "2022-02-21T00:00:00.000Z",
        "dateUpdated": "2025-04-21T13:54:36.799Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",