Vulnerabilites related to schneider-electric - apc_easy_ups_online_monitoring_software
Vulnerability from fkie_nvd
Published
2023-02-01 04:15
Modified
2024-11-21 07:25
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B8FBFEF-F5DC-4F71-B990-B74C68733741", "versionEndExcluding": "2.5-ga-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "C587FB36-A05E-4925-B643-D52EE7AEF952", "versionEndExcluding": "2.5-gs-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "F73E8580-C9EF-4F21-A5D0-468D85BDDEE1", "versionEndExcluding": "2.5-ga", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2CC95E9-44AE-4809-83DE-4AFDA682305B", "versionEndExcluding": "2.5-gs", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ], "id": "CVE-2022-42973", "lastModified": "2024-11-21T07:25:43.087", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-01T04:15:09.107", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-01 04:15
Modified
2024-11-21 07:25
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B8FBFEF-F5DC-4F71-B990-B74C68733741", "versionEndExcluding": "2.5-ga-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "C587FB36-A05E-4925-B643-D52EE7AEF952", "versionEndExcluding": "2.5-gs-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "F73E8580-C9EF-4F21-A5D0-468D85BDDEE1", "versionEndExcluding": "2.5-ga", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2CC95E9-44AE-4809-83DE-4AFDA682305B", "versionEndExcluding": "2.5-gs", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ], "id": "CVE-2022-42970", "lastModified": "2024-11-21T07:25:42.587", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-01T04:15:08.880", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-18 21:15
Modified
2024-11-21 07:57
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command
Injection') vulnerability exists that could cause remote code execution when manipulating
internal methods through Java RMI interface.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "D52617D6-0503-4B6B-A59D-441E0D1F4296", "versionEndIncluding": "2.5-ga-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "1849E03C-445A-4225-AECD-B4A7502F5F3B", "versionEndIncluding": "2.5-gs-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface." } ], "id": "CVE-2023-29412", "lastModified": "2024-11-21T07:57:00.663", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-04-18T21:15:09.457", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-01 04:15
Modified
2024-11-21 07:25
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B8FBFEF-F5DC-4F71-B990-B74C68733741", "versionEndExcluding": "2.5-ga-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "C587FB36-A05E-4925-B643-D52EE7AEF952", "versionEndExcluding": "2.5-gs-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "F73E8580-C9EF-4F21-A5D0-468D85BDDEE1", "versionEndExcluding": "2.5-ga", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2CC95E9-44AE-4809-83DE-4AFDA682305B", "versionEndExcluding": "2.5-gs", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ], "id": "CVE-2022-42971", "lastModified": "2024-11-21T07:25:42.773", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-01T04:15:08.953", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-434" } ], "source": "cybersecurity@se.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-434" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-18 21:15
Modified
2024-11-21 07:57
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause
Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor
service.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "D52617D6-0503-4B6B-A59D-441E0D1F4296", "versionEndIncluding": "2.5-ga-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "1849E03C-445A-4225-AECD-B4A7502F5F3B", "versionEndIncluding": "2.5-gs-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n" } ], "id": "CVE-2023-29413", "lastModified": "2024-11-21T07:57:00.790", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-04-18T21:15:09.523", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-01 04:15
Modified
2024-11-21 07:25
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B8FBFEF-F5DC-4F71-B990-B74C68733741", "versionEndExcluding": "2.5-ga-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "C587FB36-A05E-4925-B643-D52EE7AEF952", "versionEndExcluding": "2.5-gs-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "F73E8580-C9EF-4F21-A5D0-468D85BDDEE1", "versionEndExcluding": "2.5-ga", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2CC95E9-44AE-4809-83DE-4AFDA682305B", "versionEndExcluding": "2.5-gs", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ], "id": "CVE-2022-42972", "lastModified": "2024-11-21T07:25:42.930", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-01T04:15:09.023", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-732" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-04-18 21:15
Modified
2024-11-21 07:57
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow
changes to administrative credentials, leading to potential remote code execution without
requiring prior authentication on the Java RMI interface.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "D52617D6-0503-4B6B-A59D-441E0D1F4296", "versionEndIncluding": "2.5-ga-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "1849E03C-445A-4225-AECD-B4A7502F5F3B", "versionEndIncluding": "2.5-gs-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n" } ], "id": "CVE-2023-29411", "lastModified": "2024-11-21T07:57:00.540", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-04-18T21:15:09.390", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "cybersecurity@se.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2023-29413 (GCVE-0-2023-29413)
Vulnerability from cvelistv5
Published
2023-04-18 20:50
Modified
2025-02-05 20:59
Severity ?
EPSS score ?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause
Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor
service.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Version: V2.5-GA-01-22320 < |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:45.947Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-29413", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T20:59:10.323751Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:59:20.742Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GA-01-22320", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GS-01-22320", "versionType": "custom" } ] } ], "datePublic": "2023-04-11T07:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n" } ], "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:50:53.336Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-29413", "datePublished": "2023-04-18T20:50:53.336Z", "dateReserved": "2023-04-05T20:35:41.367Z", "dateUpdated": "2025-02-05T20:59:20.742Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-42972 (GCVE-0-2022-42972)
Vulnerability from cvelistv5
Published
2023-02-01 00:00
Modified
2025-02-05 20:06
Severity ?
EPSS score ?
Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | APC Easy UPS Online Monitoring Software |
Version: Windows 7, 10, 11 Windows Server 2016, 2019, 2022 < V2.5-GA |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:19:05.534Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-42972", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:52:18.807602Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:06:37.394Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "APC Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GA", "status": "affected", "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "versionType": "custom" } ] }, { "product": "APC Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GA-01-22261", "status": "affected", "version": "(Windows 11, Windows Server 2019, 2022", "versionType": "custom" } ] }, { "product": "Schneider Electric Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GS", "status": "affected", "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "versionType": "custom" } ] }, { "product": "Schneider Electric Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GS-01-22261", "status": "affected", "version": "Windows 11, Windows Server 2019, 2022", "versionType": "custom" } ] } ], "datePublic": "2022-12-13T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732 Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-01T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-42972", "datePublished": "2023-02-01T00:00:00.000Z", "dateReserved": "2022-10-17T00:00:00.000Z", "dateUpdated": "2025-02-05T20:06:37.394Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-29412 (GCVE-0-2023-29412)
Vulnerability from cvelistv5
Published
2023-04-18 20:50
Modified
2025-02-05 21:00
Severity ?
EPSS score ?
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command
Injection') vulnerability exists that could cause remote code execution when manipulating
internal methods through Java RMI interface.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Version: V2.5-GA-01-22320 < |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:46.159Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-29412", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T21:00:28.496674Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T21:00:38.906Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GA-01-22320", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GS-01-22320", "versionType": "custom" } ] } ], "datePublic": "2023-04-11T07:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nCWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface.\n\n" } ], "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-12T12:20:18.929Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-29412", "datePublished": "2023-04-18T20:50:08.288Z", "dateReserved": "2023-04-05T20:35:41.367Z", "dateUpdated": "2025-02-05T21:00:38.906Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-42973 (GCVE-0-2022-42973)
Vulnerability from cvelistv5
Published
2023-02-01 00:00
Modified
2025-02-05 20:06
Severity ?
EPSS score ?
Summary
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | APC Easy UPS Online Monitoring Software |
Version: Windows 7, 10, 11 Windows Server 2016, 2019, 2022 < V2.5-GA |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:19:05.491Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-42973", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:52:15.476887Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:06:29.119Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "APC Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GA", "status": "affected", "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "versionType": "custom" } ] }, { "product": "APC Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GA-01-22261", "status": "affected", "version": "(Windows 11, Windows Server 2019, 2022", "versionType": "custom" } ] }, { "product": "Schneider Electric Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GS", "status": "affected", "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "versionType": "custom" } ] }, { "product": "Schneider Electric Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GS-01-22261", "status": "affected", "version": "Windows 11, Windows Server 2019, 2022", "versionType": "custom" } ] } ], "datePublic": "2022-12-13T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798 Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-01T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-42973", "datePublished": "2023-02-01T00:00:00.000Z", "dateReserved": "2022-10-17T00:00:00.000Z", "dateUpdated": "2025-02-05T20:06:29.119Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-42971 (GCVE-0-2022-42971)
Vulnerability from cvelistv5
Published
2023-02-01 00:00
Modified
2025-02-05 20:16
Severity ?
EPSS score ?
Summary
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | APC Easy UPS Online Monitoring Software |
Version: Windows 7, 10, 11 Windows Server 2016, 2019, 2022 < V2.5-GA |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:19:05.546Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-42971", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:56:34.500669Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:16:59.507Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "APC Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GA", "status": "affected", "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "versionType": "custom" } ] }, { "product": "APC Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GA-01-22261", "status": "affected", "version": "(Windows 11, Windows Server 2019, 2022", "versionType": "custom" } ] }, { "product": "Schneider Electric Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GS", "status": "affected", "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "versionType": "custom" } ] }, { "product": "Schneider Electric Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GS-01-22261", "status": "affected", "version": "Windows 11, Windows Server 2019, 2022", "versionType": "custom" } ] } ], "datePublic": "2022-12-13T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-434", "description": "CWE-434 Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-01T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-42971", "datePublished": "2023-02-01T00:00:00.000Z", "dateReserved": "2022-10-17T00:00:00.000Z", "dateUpdated": "2025-02-05T20:16:59.507Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-42970 (GCVE-0-2022-42970)
Vulnerability from cvelistv5
Published
2023-02-01 00:00
Modified
2025-02-05 20:17
Severity ?
EPSS score ?
Summary
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | APC Easy UPS Online Monitoring Software |
Version: Windows 7, 10, 11 Windows Server 2016, 2019, 2022 < V2.5-GA |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:19:05.522Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-42970", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:56:37.171973Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T20:17:08.771Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "APC Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GA", "status": "affected", "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "versionType": "custom" } ] }, { "product": "APC Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GA-01-22261", "status": "affected", "version": "(Windows 11, Windows Server 2019, 2022", "versionType": "custom" } ] }, { "product": "Schneider Electric Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GS", "status": "affected", "version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "versionType": "custom" } ] }, { "product": "Schneider Electric Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V2.5-GS-01-22261", "status": "affected", "version": "Windows 11, Windows Server 2019, 2022", "versionType": "custom" } ] } ], "datePublic": "2022-12-13T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-01T00:00:00.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2022-42970", "datePublished": "2023-02-01T00:00:00.000Z", "dateReserved": "2022-10-17T00:00:00.000Z", "dateUpdated": "2025-02-05T20:17:08.771Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-29411 (GCVE-0-2023-29411)
Vulnerability from cvelistv5
Published
2023-04-18 20:49
Modified
2025-02-05 21:22
Severity ?
EPSS score ?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow
changes to administrative credentials, leading to potential remote code execution without
requiring prior authentication on the Java RMI interface.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Version: V2.5-GA-01-22320 < |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:46.023Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-29411", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T21:21:55.206695Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T21:22:08.895Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GA-01-22320", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "prior", "status": "affected", "version": "V2.5-GS-01-22320", "versionType": "custom" } ] } ], "datePublic": "2023-04-11T07:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n" } ], "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:49:34.059Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-29411", "datePublished": "2023-04-18T20:49:34.059Z", "dateReserved": "2023-04-05T20:35:41.367Z", "dateUpdated": "2025-02-05T21:22:08.895Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }