{"uuid": "8cb3bd2a-8a22-4653-a75a-24eba519ff18", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2026-33862", "type": "seen", "source": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-04", "content": "View CSAF\n\nSummary\n\nSiemens Teamcenter is affected by multiple vulnerabilities which could potentially lead to a compromise in availability, integrity and confidentiality. Siemens has released new versions for the affected products and recommends to update to the latest versions.\n\nThe following versions of Siemens Teamcenter are affected:\n\n\n\nTeamcenter V2312 vers:intdot/&lt;2312.0014, vers:intdot/&lt;2312.0009 (CVE-2026-33862, CVE-2026-33893, CVE-2024-4367)\n\nTeamcenter V2406 vers:intdot/&lt;2406.0012, vers:intdot/&lt;2406.0006 (CVE-2026-33862, CVE-2026-33893, CVE-2024-4367)\n\nTeamcenter V2412 vers:intdot/&lt;2412.0009 (CVE-2026-33862, CVE-2026-33893)\n\nTeamcenter V2506 vers:intdot/&lt;2506.0005 (CVE-2026-33862, CVE-2026-33893)\n\nTeamcenter V2512 vers:all/*&nbsp;\n\n&lt;div class=\"csaf-table\"&gt;\n\n\n\n\nCVSS\nVendor\nEquipment\nVulnerabilities\n\n\n\n\nv3 7.5\nSiemens\nSiemens Teamcenter\nImproper Check for Unusual or Exceptional Conditions, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Use of Hard-coded Credentials\n\n\n\n&lt;/div&gt;\n\nBackground\n\n\n\nCritical Infrastructure Sectors: Critical Manufacturing\n\nCountries/Areas Deployed: Worldwide\n\nCompany Headquarters Location: Germany\n\n\n\n\nVulnerabilities\n&lt;div class=\"csaf-accordion\"&gt;\n\nExpand All +\n&lt;div class=\"csaf-accordion-item\"&gt;\n\nCVE-2024-4367\n&lt;div class=\"csaf-accordion-content\"&gt;\n\nA type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulnerability affects Firefox &lt; 126, Firefox ESR &lt; 115.11, and Thunderbird &lt; 115.11.\n\nView CVE Details\n\n\n\nAffected Products\n\nSiemens Teamcenter\n&lt;div class=\"ics-vendor-version-status\"&gt;\n&lt;div class=\"ics-vendor\"&gt;Vendor:Siemens&lt;/div&gt;\n&lt;div class=\"ics-version\"&gt;Product Version:Teamcenter V2312, Teamcenter V2406&lt;/div&gt;\n&lt;div class=\"ics-status\"&gt;Product Status:known_affected, known_not_affected&lt;/div&gt;\n&lt;/div&gt;\n&lt;div class=\"ics-remediations\"&gt;\n\nRemediations\n\nVendor fixUpdate to V2312.0009 or later versionhttps://support.sw.siemens.com/product/282219420/\n\nVendor fixUpdate to V2406.0006 or later versionhttps://support.sw.siemens.com/product/282219420/\n&lt;/div&gt;\n\nRelevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions\n\n\n\nMetrics\n&lt;div class=\"csaf-table csaf-metrics-table\"&gt;\n\n\n\n\nCVSS Version\nBase Score\nBase Severity\nVector String\n\n\n\n\n3.1\n5.6\nMEDIUM\nCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L\n\n\n\n&lt;/div&gt;\n&lt;/div&gt;\n&lt;/div&gt;\n&lt;div class=\"csaf-accordion-item\"&gt;\n\nCVE-2026-33862\n&lt;div class=\"csaf-accordion-content\"&gt;\n\nThe affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page.\n\nView CVE Details\n\n\n\nAffected Products\n\nSiemens Teamcenter\n&lt;div class=\"ics-vendor-version-status\"&gt;\n&lt;div class=\"ics-vendor\"&gt;Vendor:Siemens&lt;/div&gt;\n&lt;div class=\"ics-version\"&gt;Product Version:Teamcenter V2312, Teamcenter V2406, Teamcenter V2412, Teamcenter V2506&lt;/div&gt;\n&lt;div class=\"ics-status\"&gt;Product Status:known_affected, known_not_affected&lt;/div&gt;\n&lt;/div&gt;\n&lt;div class=\"ics-remediations\"&gt;\n\nRemediations\n\nVendor fixUpdate to V2312.0014 or later versionhttps://support.sw.siemens.com/product/282219420/\n\nVendor fixUpdate to V2406.0012 or later versionhttps://support.sw.siemens.com/product/282219420/\n\nVendor fixUpdate to V2412.0009 or later versionhttps://support.sw.siemens.com/product/282219420/\n\nVendor fixUpdate to V2506.0005 or later versionhttps://support.sw.siemens.com/product/282219420/\n&lt;/div&gt;\n\nRelevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')\n\n\n\nMetrics\n&lt;div class=\"csaf-table csaf-metrics-table\"&gt;\n\n\n\n\nCVSS Version\nBase Score\nBase Severity\nVector String\n\n\n\n\n3.1\n7.3\nHIGH\nCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N\n\n\n\n&lt;/div&gt;\n&lt;/div&gt;\n&lt;/div&gt;\n&lt;div class=\"csaf-accordion-item\"&gt;\n\nCVE-2026-33893\n&lt;div class=\"csaf-accordion-content\"&gt;\n\nThe affected application contains hardcoded key which is used for obfuscation stored directly into the application. This could allow an attacker to obtain these keys and misuse them to gain unauthorized access.\n\nView CVE Details\n\n\n\nAffected Products\n\nSiemens Teamcenter\n&lt;div class=\"ics-vendor-version-status\"&gt;\n&lt;div class=\"ics-vendor\"&gt;Vendor:Siemens&lt;/div&gt;\n&lt;div class=\"ics-version\"&gt;Product Version:Teamcenter V2312, Teamcenter V2406, Teamcenter V2412, Teamcenter V2506&lt;/div&gt;\n&lt;div class=\"ics-status\"&gt;Product Status:known_affected, known_not_affected&lt;/div&gt;\n&lt;/div&gt;\n&lt;div class=\"ics-remediations\"&gt;\n\nRemediations\n\nVendor fixUpdate to V2312.0014 or later versionhttps://support.sw.siemens.com/product/282219420/\n\nVendor fixUpdate to V2406.0012 or later versionhttps://support.sw.siemens.com/product/282219420/\n\nVendor fixUpdate to V2412.0009 or later versionhttps://support.sw.siemens.com/product/282219420/\n\nVendor fixUpdate to V2506.0005 or later versionhttps://support.sw.siemens.com/product/282219420/\n&lt;/div&gt;\n\nRelevant CWE: CWE-798 Use of Hard-coded Credentials\n\n\n\nMetrics\n&lt;div class=\"csaf-table csaf-metrics-table\"&gt;\n\n\n\n\nCVSS Version\nBase Score\nBase Severity\nVector String\n\n\n\n\n3.1\n7.5\nHIGH\nCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\n\n\n\n&lt;/div&gt;\n&lt;/div&gt;\n&lt;/div&gt;\n&lt;/div&gt;\n\n\n\nAcknowledgments\n\n\n\nDustin Born, Robin Plugge, and Tim W\u00f6rner of usd AG reported these vulnerabilities.\n\n\n\n\nGeneral Recommendations\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity\n\n\n\nAdditional Resources\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories\n\n\n\nTerms of Use\n\nThe use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.\n\n\n\nLegal Notice and Terms of Use\n\nThis product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy &amp; Use policy (https://www.cisa.gov/privacy-policy).\n\n\n\nRecommended Practices\n\nCISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.\n\nLocate control system networks and remote devices behind firewalls and isolate them from business networks.\n\nWhen remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.\n\nCISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\n\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.\n\nCISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\n\nOrganizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.\n\n\n\nAdvisory Conversion Disclaimer\n\nThis ICSA is a verbatim republication of Siemens ProductCERT SSA-827383 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.\n\nRevision History\n\n\n\nInitial Release Date: 2026-05-12\n\n\n\n\n\nDate\nRevision\nSummary\n\n\n\n\n2026-05-12\n1\nPublication Date\n\n\n2026-05-14\n2\nInitial CISA Republication of Siemens ProductCERT SSA-827383 advisory\n\n\n\n\n\n\nLegal Notice and Terms of Use", "creation_timestamp": "2026-05-14T10:00:00.000000Z"}