{"uuid": "b3d8d9fa-5d50-4cad-a061-8fa560b2e2db", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2011-2089", "type": "seen", "source": "https://github.com/rapid7/metasploit-framework/blob/master/modules/exploits/windows/scada/iconics_webhmi_setactivexguid.rb", "content": "{\"aliases\": [], \"arch\": \"\", \"author\": [\"Scoot Bell \", \"Blair Strang \", \"sinn3r \"], \"autofilter_ports\": [], \"autofilter_services\": [], \"check\": false, \"default_credential\": false, \"description\": \"This module exploits a vulnerability found in ICONICS WebHMI's ActiveX control.\\n          By supplying a long string of data to the 'SetActiveXGUID' parameter, GenVersion.dll\\n          fails to do any proper bounds checking before this input is copied onto the stack,\\n          which causes a buffer overflow, and results arbitrary code execution under the context\\n          of the user.\", \"disclosure_date\": \"2011-05-05\", \"fullname\": \"exploit/windows/scada/iconics_webhmi_setactivexguid\", \"is_install_path\": true, \"mod_time\": \"2025-06-23 12:43:46 +0000\", \"name\": \"ICONICS WebHMI ActiveX Buffer Overflow\", \"needs_cleanup\": null, \"notes\": {\"Reliability\": [\"unknown-reliability\"], \"SideEffects\": [\"unknown-side-effects\"], \"Stability\": [\"unknown-stability\"]}, \"path\": \"/modules/exploits/windows/scada/iconics_webhmi_setactivexguid.rb\", \"platform\": \"Windows\", \"post_auth\": false, \"rank\": 400, \"ref_name\": \"windows/scada/iconics_webhmi_setactivexguid\", \"references\": [\"CVE-2011-2089\", \"OSVDB-72135\", \"URL-http://www.security-assessment.com/files/documents/advisory/ICONICS_WebHMI.pdf\", \"EDB-17240\", \"URL-https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-11-080-02\"], \"rport\": null, \"session_types\": false, \"targets\": [\"Automatic\", \"IE 6/7/8 on Windows XP SP3\", \"IE 7 on Windows Vista\"], \"type\": \"exploit\"}", "creation_timestamp": "2026-09-08T06:52:28.678145Z"}