<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent sightings.</title>
    <link>https://vulnerability.circl.lu</link>
    <description>Contains only the most 10 recent sightings.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Mon, 04 May 2026 21:00:02 +0000</lastBuildDate>
    <item>
      <title>3f8870e8-72fb-4332-90f2-86c8069c8ee3</title>
      <link>https://vulnerability.circl.lu/sighting/3f8870e8-72fb-4332-90f2-86c8069c8ee3/export</link>
      <description>{"uuid": "3f8870e8-72fb-4332-90f2-86c8069c8ee3", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2021-46606", "type": "seen", "source": "https://t.me/cibsecurity/37757", "content": "\u203c CVE-2021-46606 \u203c\n\nThis vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of BMP images. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15400.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2022-02-18T22:40:48.000000Z"}</description>
      <content:encoded>{"uuid": "3f8870e8-72fb-4332-90f2-86c8069c8ee3", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2021-46606", "type": "seen", "source": "https://t.me/cibsecurity/37757", "content": "\u203c CVE-2021-46606 \u203c\n\nThis vulnerability allows remote attackers to execute arbitrary code on affected installations of Bentley MicroStation CONNECT 10.16.0.80. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of BMP images. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15400.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2022-02-18T22:40:48.000000Z"}</content:encoded>
      <guid isPermaLink="false">https://vulnerability.circl.lu/sighting/3f8870e8-72fb-4332-90f2-86c8069c8ee3/export</guid>
      <pubDate>Fri, 18 Feb 2022 22:40:48 +0000</pubDate>
    </item>
  </channel>
</rss>
