{"vulnerability": "cve-2013-2807", "sightings": [{"uuid": "a3d8f8f2-3203-4d61-a034-6aac4f2ca079", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2013-2807", "type": "seen", "source": "https://t.me/cibsecurity/3364", "content": "ATENTION\u203c New - CVE-2013-2807\n\nRockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the ?Total Record Size? field. By sending a datagram to the service over Port 4444/UDP with the ?Record Data Size? field modified to a specifically oversized value, the service will calculate an undersized value for the ?Total Record Size? that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2019-03-26T19:32:12.000000Z"}]}