{"vulnerability": "cve-2022-3442", "sightings": [{"uuid": "6b399d23-8ec8-4f2b-abbb-cf464dd397f6", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-34421", "type": "seen", "source": "https://t.me/cibsecurity/60136", "content": "\u203c CVE-2022-34421 \u203c\n\nDell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2023-03-16T15:31:04.000000Z"}, {"uuid": "66869507-a818-4f79-abdf-b813c36efd44", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-34424", "type": "seen", "source": "https://t.me/DarkWebInformer_CVEAlerts/17078", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2022-34424\n\ud83d\udd25 CVSS Score: 7.5 (cvssV3_1, Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)\n\ud83d\udd39 Description: Networking OS10, versions 10.5.1.x, 10.5.2.x, and 10.5.3.x contain a vulnerability that could allow an attacker to cause a system crash by running particular security scans.\n\ud83d\udccf Published: 2022-09-28T20:30:18.565Z\n\ud83d\udccf Modified: 2025-05-20T20:28:43.591Z\n\ud83d\udd17 References:\n1. https://www.dell.com/support/kbdoc/en-us/000202971/dsa-2022-135-dell-emc-smartfabric-os10-security-update-for-multiple-security-vulnerabilities", "creation_timestamp": "2025-05-20T20:41:11.000000Z"}, {"uuid": "78773b95-c4b4-42e2-8aa4-5ac723607363", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-34422", "type": "seen", "source": "https://t.me/cibsecurity/60127", "content": "\u203c CVE-2022-34422 \u203c\n\nDell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2023-03-16T15:30:50.000000Z"}, {"uuid": "cd54c52b-0436-4bf2-8a87-68c99836535b", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-34427", "type": "seen", "source": "https://t.me/cibsecurity/51136", "content": "\u203c CVE-2022-34427 \u203c\n\nDell Container Storage Modules 1.2 contains an OS Command Injection in goiscsi and gobrick libraries. A remote unauthenticated attacker could exploit this vulnerability leading to modification of intended OS command execution.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2022-10-11T20:26:12.000000Z"}, {"uuid": "b15846a7-4097-485b-938c-2a06ca89935c", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-34420", "type": "seen", "source": "https://t.me/cibsecurity/60128", "content": "\u203c CVE-2022-34420 \u203c\n\nDell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2023-03-16T15:30:51.000000Z"}, {"uuid": "753b0199-d5fb-422d-a3e8-3ed6ffe22d22", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-34423", "type": "seen", "source": "https://t.me/cibsecurity/60130", "content": "\u203c CVE-2022-34423 \u203c\n\nDell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2023-03-16T15:30:55.000000Z"}, {"uuid": "c7422374-c34f-444b-8faa-7012c46c96df", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-3442", "type": "seen", "source": "https://t.me/cibsecurity/51065", "content": "\u203c CVE-2022-3442 \u203c\n\nA vulnerability was found in Crealogix EBICS 7.0. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /ebics-server/ebics.aspx. The manipulation leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 7.1 is able to address this issue. It is recommended to upgrade the affected component. VDB-210374 is the identifier assigned to this vulnerability.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2022-10-11T11:11:14.000000Z"}, {"uuid": "56b2bf64-b95d-4aa9-a652-c7811c2ef636", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-34424", "type": "seen", "source": "https://t.me/cibsecurity/50626", "content": "\u203c CVE-2022-34424 \u203c\n\nNetworking OS10, versions 10.5.1.x, 10.5.2.x, and 10.5.3.x contain a vulnerability that could allow an attacker to cause a system crash by running particular security scans.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2022-09-29T00:34:30.000000Z"}, {"uuid": "a629a7ad-724e-4742-b4f9-239a2449a399", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2022-34426", "type": "seen", "source": "https://t.me/cibsecurity/51135", "content": "\u203c CVE-2022-34426 \u203c\n\nDell Container Storage Modules 1.2 contains an Improper Limitation of a Pathname to a Restricted Directory in goiscsi and gobrick libraries which could lead to OS command injection. A remote unauthenticated attacker could exploit this vulnerability leading to unintentional access to path outside of restricted directory.\n\n\ud83d\udcd6 Read\n\nvia \"National Vulnerability Database\".", "creation_timestamp": "2022-10-11T20:26:11.000000Z"}]}