{"vulnerability": "cve-2024-4897", "sightings": [{"uuid": "a4ebb835-f233-4c9c-aded-c19f92fc8be5", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-48971", "type": "seen", "source": "https://infosec.exchange/users/cve/statuses/113483413532383578", "content": "", "creation_timestamp": "2024-11-14T21:24:29.710026Z"}, {"uuid": "530f67d3-7ec8-4fce-9eba-64936cd9970d", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-48970", "type": "seen", "source": "https://t.me/cvedetector/11017", "content": "{\n  \"Source\": \"CVE FEED\",\n  \"Title\": \"CVE-2024-48970 - Medtronic Ventilator Information Disclosure and Control Manipulation\", \n  \"Content\": \"CVE ID : CVE-2024-48970 \nPublished : Nov. 14, 2024, 10:15 p.m. | 38\u00a0minutes ago \nDescription : The ventilator's microcontroller lacks memory protection. An attacker could connect to the internal JTAG interface and read or write to flash memory using an off-the-shelf debugging tool, which could disrupt the function of the device and/or cause unauthorized information disclosure. \nSeverity: 9.3 | CRITICAL \nVisit the link for more details, such as CVSS details, affected products, timeline, and more...\",\n  \"Detection Date\": \"14 Nov 2024\",\n  \"Type\": \"Vulnerability\"\n}\n\ud83d\udd39 t.me/cvedetector \ud83d\udd39", "creation_timestamp": "2024-11-15T00:11:35.000000Z"}, {"uuid": "e73247ed-93ec-4ad0-b59d-88b6912aeb8f", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-48971", "type": "seen", "source": "MISP/1c5c38d6-3401-41ac-be0e-4cf361fa6f51", "content": "", "creation_timestamp": "2025-09-25T00:36:28.000000Z"}, {"uuid": "ae735ae0-faa5-4fb1-9554-d92720d7ac50", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-48974", "type": "seen", "source": "https://t.me/cvedetector/11020", "content": "{\n  \"Source\": \"CVE FEED\",\n  \"Title\": \"CVE-2024-48974 - Medtronic Ventilator Firmware Update Insecure Configuration and Code Execution\", \n  \"Content\": \"CVE ID : CVE-2024-48974 \nPublished : Nov. 14, 2024, 10:15 p.m. | 38\u00a0minutes ago \nDescription : The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings and/or compromise device functionality by pushing a compromised/illegitimate firmware file. This could disrupt the function of the device and/or cause unauthorized information disclosure. \nSeverity: 9.3 | CRITICAL \nVisit the link for more details, such as CVSS details, affected products, timeline, and more...\",\n  \"Detection Date\": \"14 Nov 2024\",\n  \"Type\": \"Vulnerability\"\n}\n\ud83d\udd39 t.me/cvedetector \ud83d\udd39", "creation_timestamp": "2024-11-15T00:11:37.000000Z"}, {"uuid": "e5961b30-0caf-490e-907b-24cb73fca9a9", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-48973", "type": "seen", "source": "https://t.me/cvedetector/11019", "content": "{\n  \"Source\": \"CVE FEED\",\n  \"Title\": \"CVE-2024-48973 - Medtronic Ventilator Default Debug Port Unchecked Access Vulnerability\", \n  \"Content\": \"CVE ID : CVE-2024-48973 \nPublished : Nov. 14, 2024, 10:15 p.m. | 38\u00a0minutes ago \nDescription : The debug port on the ventilator's serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which are unencrypted; see 3.2.1) that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. \nSeverity: 9.3 | CRITICAL \nVisit the link for more details, such as CVSS details, affected products, timeline, and more...\",\n  \"Detection Date\": \"14 Nov 2024\",\n  \"Type\": \"Vulnerability\"\n}\n\ud83d\udd39 t.me/cvedetector \ud83d\udd39", "creation_timestamp": "2024-11-15T00:11:36.000000Z"}, {"uuid": "be0384ab-62c5-45b0-9746-e1a47f05162e", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2024-48971", "type": "seen", "source": "https://t.me/cvedetector/11018", "content": "{\n  \"Source\": \"CVE FEED\",\n  \"Title\": \"CVE-2024-48971 - Philips Ventillator Unencrypted Credentials\", \n  \"Content\": \"CVE ID : CVE-2024-48971 \nPublished : Nov. 14, 2024, 10:15 p.m. | 38\u00a0minutes ago \nDescription : The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges. \nSeverity: 9.3 | CRITICAL \nVisit the link for more details, such as CVSS details, affected products, timeline, and more...\",\n  \"Detection Date\": \"14 Nov 2024\",\n  \"Type\": \"Vulnerability\"\n}\n\ud83d\udd39 t.me/cvedetector \ud83d\udd39", "creation_timestamp": "2024-11-15T00:11:36.000000Z"}]}