{"vulnerability": "cve-2025-20174", "sightings": [{"uuid": "12e1290d-7911-4534-9c88-1e721213ad43", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2025-20174", "type": "seen", "source": "https://bsky.app/profile/cve.skyfleet.blue/post/3lhhfwhof4t2z", "content": "", "creation_timestamp": "2025-02-05T20:28:50.828820Z"}, {"uuid": "7ff9325f-9250-4368-ac2c-147807d72af4", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2025-20174", "type": "seen", "source": "https://infosec.exchange/users/screaminggoat/statuses/113952255128702135", "content": "", "creation_timestamp": "2025-02-05T16:37:05.199892Z"}, {"uuid": "2a138bc5-4e63-4326-9de0-c2f399249d6b", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2025-20174", "type": "seen", "source": "https://bsky.app/profile/cve-notifications.bsky.social/post/3lhh35yszmu2j", "content": "", "creation_timestamp": "2025-02-05T17:16:07.665490Z"}, {"uuid": "71986245-d76d-4a39-bd26-43709b454c10", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2025-20174", "type": "seen", "source": "https://t.me/cvedetector/17305", "content": "{\n  \"Source\": \"CVE FEED\",\n  \"Title\": \"CVE-2025-20174 - Cisco SNMP Improper Error Handling Remote Denial of Service Vulnerability\", \n  \"Content\": \"CVE ID : CVE-2025-20174 \nPublished : Feb. 5, 2025, 5:15 p.m. | 49\u00a0minutes ago \nDescription : A vulnerability in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device.  \n  \nThis vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition.\u00a0  \nThis vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system. \nSeverity: 7.7 | HIGH \nVisit the link for more details, such as CVSS details, affected products, timeline, and more...\",\n  \"Detection Date\": \"05 Feb 2025\",\n  \"Type\": \"Vulnerability\"\n}\n\ud83d\udd39 t.me/cvedetector \ud83d\udd39", "creation_timestamp": "2025-02-05T19:09:08.000000Z"}, {"uuid": "e7f593c7-eaf0-4251-bd5a-3fa65e534699", "vulnerability_lookup_origin": "1a89b78e-f703-45f3-bb86-59eb712668bd", "author": "9f56dd64-161d-43a6-b9c3-555944290a09", "vulnerability": "CVE-2025-20174", "type": "seen", "source": "http://www.zerodayinitiative.com/advisories/ZDI-25-276/", "content": "", "creation_timestamp": "2025-05-01T03:00:00.000000Z"}]}