All the vulnerabilites related to Microsoft - .NET-SDK
cve-2023-0755
Vulnerability from cvelistv5
Published
2023-02-23 21:23
Modified
2024-08-02 05:24
Severity ?
EPSS score ?
Summary
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:24:34.155Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ThingWorx Edge C-SDK", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v2.2.12.1052 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": ".NET-SDK", "vendor": "Microsoft", "versions": [ { "lessThanOrEqual": "v5.8.4.971 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Edge MicroServer (EMS)", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v5.4.10.0 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Kepware KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v6.12 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Server ", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v6.12 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "status": "affected", "version": "All Versions " } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Edge", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v1.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "KEPServer Enterprise ", "vendor": "Rockwell Automation ", "versions": [ { "lessThanOrEqual": "v6.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Digital Industrial Gateway Server ", "vendor": "General Electric ", "versions": [ { "lessThanOrEqual": "v7.612", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA." } ], "datePublic": "2023-02-23T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\u003c/span\u003e\n\n" } ], "value": "\nThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-129", "description": "CWE-129 Improper Validation of Array Index", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-23T21:23:19.210Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e" } ], "value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-0755", "datePublished": "2023-02-23T21:23:19.210Z", "dateReserved": "2023-02-08T20:21:34.258Z", "dateUpdated": "2024-08-02T05:24:34.155Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-0754
Vulnerability from cvelistv5
Published
2023-02-23 21:27
Modified
2024-08-02 05:24
Severity ?
EPSS score ?
Summary
The affected products are vulnerable to an integer
overflow or wraparound, which could allow an attacker to crash the server and remotely
execute arbitrary code.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:24:34.053Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ThingWorx Edge C-SDK", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v2.2.12.1052 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": ".NET-SDK", "vendor": "Microsoft", "versions": [ { "lessThanOrEqual": "v5.8.4.971 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Edge MicroServer (EMS)", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v5.4.10.0 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Kepware KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v6.12 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Server ", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v6.12 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "status": "affected", "version": "All Versions " } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Edge", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v1.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "KEPServer Enterprise ", "vendor": "Rockwell Automation ", "versions": [ { "lessThanOrEqual": "v6.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Digital Industrial Gateway Server ", "vendor": "General Electric ", "versions": [ { "lessThanOrEqual": "v7.612", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003eThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u0026nbsp;allow an attacker to crash the server and remotely\nexecute arbitrary code.\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003e\u003c/p\u003e\n\n\n\n\n\n" } ], "value": "\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u00a0allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-190", "description": "CWE-190 Integer Overflow or Wraparound", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-23T21:27:09.964Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e" } ], "value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-0754", "datePublished": "2023-02-23T21:27:09.964Z", "dateReserved": "2023-02-08T20:15:58.394Z", "dateUpdated": "2024-08-02T05:24:34.053Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }