Search criteria
5 vulnerabilities found for 3par_service_provider by hpe
CVE-2024-22442 (GCVE-0-2024-22442)
Vulnerability from cvelistv5 – Published: 2024-07-16 15:45 – Updated: 2024-08-01 22:43
VLAI?
Summary
The vulnerability could be remotely exploited to bypass authentication.
Severity ?
9.8 (Critical)
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE 3PAR Service Processor |
Affected:
5.1.1 and earlier
(custom)
|
Credits
Hewlett Packard Enterprise acknowledges Milad Fadavvi for reporting this issue to security-alert@hpe.com.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:hp:3par_service_processor_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "3par_service_processor_firmware",
"vendor": "hp",
"versions": [
{
"lessThan": "5.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22442",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-16T17:49:29.321484Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-16T18:11:59.880Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:43:34.901Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbst04663en_us\u0026docLocale=en_US"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "HPE 3PAR Service Processor",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"status": "affected",
"version": "5.1.1 and earlier",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Hewlett Packard Enterprise acknowledges Milad Fadavvi for reporting this issue to security-alert@hpe.com."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability could be remotely exploited to bypass authentication."
}
],
"value": "The vulnerability could be remotely exploited to bypass authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-16T15:45:51.809Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbst04663en_us\u0026docLocale=en_US"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2024-22442",
"datePublished": "2024-07-16T15:45:51.809Z",
"dateReserved": "2024-01-10T15:24:39.967Z",
"dateUpdated": "2024-08-01T22:43:34.901Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7094 (GCVE-0-2018-7094)
Vulnerability from cvelistv5 – Published: 2018-08-14 14:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-5.0.0.0-22913(GA). The vulnerability may be exploited locally to allow disclosure of privileged information.
Severity ?
No CVSS data available.
CWE
- Local Disclosure of Privileged Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE 3PAR Service Processors |
Affected:
SP-5.0.0.0-22913(GA)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.465Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE 3PAR Service Processors",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "SP-5.0.0.0-22913(GA)"
}
]
}
],
"datePublic": "2018-08-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-5.0.0.0-22913(GA). The vulnerability may be exploited locally to allow disclosure of privileged information."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Local Disclosure of Privileged Information",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-14T13:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7094",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE 3PAR Service Processors",
"version": {
"version_data": [
{
"version_value": "SP-5.0.0.0-22913(GA)"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-5.0.0.0-22913(GA). The vulnerability may be exploited locally to allow disclosure of privileged information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Local Disclosure of Privileged Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7094",
"datePublished": "2018-08-14T14:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.465Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22442 (GCVE-0-2024-22442)
Vulnerability from nvd – Published: 2024-07-16 15:45 – Updated: 2024-08-01 22:43
VLAI?
Summary
The vulnerability could be remotely exploited to bypass authentication.
Severity ?
9.8 (Critical)
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | HPE 3PAR Service Processor |
Affected:
5.1.1 and earlier
(custom)
|
Credits
Hewlett Packard Enterprise acknowledges Milad Fadavvi for reporting this issue to security-alert@hpe.com.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:hp:3par_service_processor_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "3par_service_processor_firmware",
"vendor": "hp",
"versions": [
{
"lessThan": "5.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-22442",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-16T17:49:29.321484Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-16T18:11:59.880Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:43:34.901Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbst04663en_us\u0026docLocale=en_US"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "HPE 3PAR Service Processor",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"status": "affected",
"version": "5.1.1 and earlier",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Hewlett Packard Enterprise acknowledges Milad Fadavvi for reporting this issue to security-alert@hpe.com."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability could be remotely exploited to bypass authentication."
}
],
"value": "The vulnerability could be remotely exploited to bypass authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-16T15:45:51.809Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbst04663en_us\u0026docLocale=en_US"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2024-22442",
"datePublished": "2024-07-16T15:45:51.809Z",
"dateReserved": "2024-01-10T15:24:39.967Z",
"dateUpdated": "2024-08-01T22:43:34.901Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-7094 (GCVE-0-2018-7094)
Vulnerability from nvd – Published: 2018-08-14 14:00 – Updated: 2024-08-05 06:17
VLAI?
Summary
A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-5.0.0.0-22913(GA). The vulnerability may be exploited locally to allow disclosure of privileged information.
Severity ?
No CVSS data available.
CWE
- Local Disclosure of Privileged Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | HPE 3PAR Service Processors |
Affected:
SP-5.0.0.0-22913(GA)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.465Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE 3PAR Service Processors",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "SP-5.0.0.0-22913(GA)"
}
]
}
],
"datePublic": "2018-08-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-5.0.0.0-22913(GA). The vulnerability may be exploited locally to allow disclosure of privileged information."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Local Disclosure of Privileged Information",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-14T13:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2018-7094",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE 3PAR Service Processors",
"version": {
"version_data": [
{
"version_value": "SP-5.0.0.0-22913(GA)"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-5.0.0.0-22913(GA). The vulnerability may be exploited locally to allow disclosure of privileged information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Local Disclosure of Privileged Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2018-7094",
"datePublished": "2018-08-14T14:00:00",
"dateReserved": "2018-02-15T00:00:00",
"dateUpdated": "2024-08-05T06:17:17.465Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
FKIE_CVE-2018-7094
Vulnerability from fkie_nvd - Published: 2018-08-14 14:29 - Updated: 2024-11-21 04:11
Severity ?
Summary
A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-5.0.0.0-22913(GA). The vulnerability may be exploited locally to allow disclosure of privileged information.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hpe | 3par_service_provider | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hpe:3par_service_provider:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0CC20F0C-5701-46E4-98A6-172446BCC912",
"versionEndExcluding": "sp-5.0.0.0-22913",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability was identified in 3PAR Service Processor (SP) prior to SP-5.0.0.0-22913(GA). The vulnerability may be exploited locally to allow disclosure of privileged information."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad de seguridad en 3PAR Service Processor (SP) en versiones anteriores a la SP-5.0.0.0-22913(GA). La vulnerabilidad se podr\u00eda explotar de forma local para permitir la divulgaci\u00f3n de informaci\u00f3n privilegiada."
}
],
"id": "CVE-2018-7094",
"lastModified": "2024-11-21T04:11:38.053",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-08-14T14:29:00.637",
"references": [
{
"source": "security-alert@hpe.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst03870en_us"
}
],
"sourceIdentifier": "security-alert@hpe.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}