Search criteria

4 vulnerabilities found for AC500 V2 by ABB

CVE-2025-7745 (GCVE-0-2025-7745)

Vulnerability from cvelistv5 – Published: 2025-07-24 07:09 – Updated: 2025-07-24 13:17
VLAI?
Title
Modbus TCP buffer overread
Summary
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2.
CWE
Assigner
ABB
Impacted products
Vendor Product Version
ABB AC500 V2 Affected: 0 , ≤ 2.5.2 (custom)
Create a notification for this product.
Credits
ABB acknowledges and extends gratitude to Reid Wightman of Dragos Inc for responsibly disclosing the vulnerability and providing valuable input on product improvements
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7745",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-24T13:17:42.636529Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-24T13:17:47.983Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "AC500 V2",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.5.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "ABB acknowledges and extends gratitude to Reid Wightman of Dragos Inc for responsibly disclosing the vulnerability and providing valuable input on product improvements"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Buffer Over-read vulnerability in ABB AC500 V2.\u003cp\u003eThis issue affects AC500 V2: through 2.5.2.\u003c/p\u003e"
            }
          ],
          "value": "Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:L/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-126",
              "description": "CWE-126: Buffer Over-read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-24T11:57:52.418Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011432\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Modbus TCP buffer overread",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2025-7745",
    "datePublished": "2025-07-24T07:09:11.906Z",
    "dateReserved": "2025-07-17T08:40:39.666Z",
    "dateUpdated": "2025-07-24T13:17:47.983Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3192 (GCVE-0-2022-3192)

Vulnerability from cvelistv5 – Published: 2023-03-31 16:13 – Updated: 2025-02-11 18:40
VLAI?
Title
Improper Check for Unusual or Exceptional Conditions
Summary
Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
ABB
Impacted products
Vendor Product Version
ABB AC500 V2 Affected: 2.0.0 , < 2.8.6 (release)
Create a notification for this product.
Credits
ABB thanks the following for working with us to help protect customers: CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:00:10.643Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3192",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T18:39:53.320995Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-11T18:40:07.850Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://abb.com/plc",
          "defaultStatus": "unknown",
          "packageName": "PM5xx",
          "product": "AC500 V2",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "2.8.6",
              "status": "affected",
              "version": "2.0.0",
              "versionType": "release"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "ABB thanks the following for working with us to help protect customers:  CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.\u003cp\u003eThis issue affects AC500 V2: from 2.0.0 before 2.8.6.\u003c/p\u003e"
            }
          ],
          "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-220",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-220 Client-Server Protocol Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-13T03:57:46.530Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": " Improper Check for Unusual or Exceptional Conditions",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003eUse the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis protocol/port is not affected by the DoS impact of the vulnerability.\u003cbr\u003e\u003c/div\u003e"
            }
          ],
          "value": "Use the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \n\n\nThis protocol/port is not affected by the DoS impact of the vulnerability.\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2022-3192",
    "datePublished": "2023-03-31T16:13:13.149Z",
    "dateReserved": "2022-09-13T05:57:45.421Z",
    "dateUpdated": "2025-02-11T18:40:07.850Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7745 (GCVE-0-2025-7745)

Vulnerability from nvd – Published: 2025-07-24 07:09 – Updated: 2025-07-24 13:17
VLAI?
Title
Modbus TCP buffer overread
Summary
Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2.
CWE
Assigner
ABB
Impacted products
Vendor Product Version
ABB AC500 V2 Affected: 0 , ≤ 2.5.2 (custom)
Create a notification for this product.
Credits
ABB acknowledges and extends gratitude to Reid Wightman of Dragos Inc for responsibly disclosing the vulnerability and providing valuable input on product improvements
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7745",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-24T13:17:42.636529Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-24T13:17:47.983Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "AC500 V2",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.5.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "ABB acknowledges and extends gratitude to Reid Wightman of Dragos Inc for responsibly disclosing the vulnerability and providing valuable input on product improvements"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Buffer Over-read vulnerability in ABB AC500 V2.\u003cp\u003eThis issue affects AC500 V2: through 2.5.2.\u003c/p\u003e"
            }
          ],
          "value": "Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:L/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-126",
              "description": "CWE-126: Buffer Over-read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-24T11:57:52.418Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011432\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Modbus TCP buffer overread",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2025-7745",
    "datePublished": "2025-07-24T07:09:11.906Z",
    "dateReserved": "2025-07-17T08:40:39.666Z",
    "dateUpdated": "2025-07-24T13:17:47.983Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3192 (GCVE-0-2022-3192)

Vulnerability from nvd – Published: 2023-03-31 16:13 – Updated: 2025-02-11 18:40
VLAI?
Title
Improper Check for Unusual or Exceptional Conditions
Summary
Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
ABB
Impacted products
Vendor Product Version
ABB AC500 V2 Affected: 2.0.0 , < 2.8.6 (release)
Create a notification for this product.
Credits
ABB thanks the following for working with us to help protect customers: CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:00:10.643Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3192",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-11T18:39:53.320995Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-11T18:40:07.850Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://abb.com/plc",
          "defaultStatus": "unknown",
          "packageName": "PM5xx",
          "product": "AC500 V2",
          "vendor": "ABB",
          "versions": [
            {
              "lessThan": "2.8.6",
              "status": "affected",
              "version": "2.0.0",
              "versionType": "release"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "ABB thanks the following for working with us to help protect customers:  CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.\u003cp\u003eThis issue affects AC500 V2: from 2.0.0 before 2.8.6.\u003c/p\u003e"
            }
          ],
          "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-220",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-220 Client-Server Protocol Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-13T03:57:46.530Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": " Improper Check for Unusual or Exceptional Conditions",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003eUse the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis protocol/port is not affected by the DoS impact of the vulnerability.\u003cbr\u003e\u003c/div\u003e"
            }
          ],
          "value": "Use the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \n\n\nThis protocol/port is not affected by the DoS impact of the vulnerability.\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2022-3192",
    "datePublished": "2023-03-31T16:13:13.149Z",
    "dateReserved": "2022-09-13T05:57:45.421Z",
    "dateUpdated": "2025-02-11T18:40:07.850Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}