All the vulnerabilites related to ABB - AC500 V2
cve-2022-3192
Vulnerability from cvelistv5
Published
2023-03-31 16:13
Modified
2024-08-03 01:00
Severity ?
EPSS score ?
Summary
Improper Check for Unusual or Exceptional Conditions
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T01:00:10.643Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "collectionURL": "https://abb.com/plc", "defaultStatus": "unknown", "packageName": "PM5xx", "product": "AC500 V2", "vendor": "ABB", "versions": [ { "lessThan": "2.8.6", "status": "affected", "version": "2.0.0", "versionType": "release" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "ABB thanks the following for working with us to help protect customers: CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.\u003cp\u003eThis issue affects AC500 V2: from 2.0.0 before 2.8.6.\u003c/p\u003e" } ], "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.\n\n" } ], "impacts": [ { "capecId": "CAPEC-220", "descriptions": [ { "lang": "en", "value": "CAPEC-220 Client-Server Protocol Manipulation" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-754", "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-09-13T03:57:46.530Z", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "source": { "discovery": "EXTERNAL" }, "title": " Improper Check for Unusual or Exceptional Conditions", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cdiv\u003eUse the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis protocol/port is not affected by the DoS impact of the vulnerability.\u003cbr\u003e\u003c/div\u003e" } ], "value": "Use the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \n\n\nThis protocol/port is not affected by the DoS impact of the vulnerability.\n\n\n" } ], "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2022-3192", "datePublished": "2023-03-31T16:13:13.149Z", "dateReserved": "2022-09-13T05:57:45.421Z", "dateUpdated": "2024-08-03T01:00:10.643Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }