All the vulnerabilites related to ISC - BIND 9 Supported Preview Edition
cve-2019-6468
Vulnerability from cvelistv5
Published
2019-10-09 14:17
Modified
2024-09-16 18:44
Summary
BIND Supported Preview Edition can exit with an assertion failure if nxdomain-redirect is used
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:20.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.isc.org/docs/cve-2019-6468"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.synology.com/security/advisory/Synology_SA_19_20"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIND 9 Supported Preview Edition",
          "vendor": "ISC",
          "versions": [
            {
              "status": "affected",
              "version": "BIND 9 9.10.5-S1 -\u003e 9.11.5-S5"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "ISC would like to thank Quad9 for reporting this issue."
        }
      ],
      "datePublic": "2019-04-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In BIND Supported Preview Edition, an error in the nxdomain-redirect feature can occur in versions which support EDNS Client Subnet (ECS) features. In those versions which have ECS support, enabling nxdomain-redirect is likely to lead to BIND exiting due to assertion failure. Versions affected: BIND Supported Preview Edition version 9.10.5-S1 -\u003e 9.11.5-S5. ONLY BIND Supported Preview Edition releases are affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "If nxdomain-redirect is enabled (via configuration) in a vulnerable BIND release, a malicious party can cause BIND to exit by deliberately triggering the bug.",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-12-18T17:06:12",
        "orgId": "404fd4d2-a609-4245-b543-2c944a302a22",
        "shortName": "isc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.isc.org/docs/cve-2019-6468"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.synology.com/security/advisory/Synology_SA_19_20"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to the patched release most closely related to your current version of BIND:\n\nBIND Supported Preview Edition is a special feature preview branch of BIND provided to eligible ISC support customers.\n\n+    BIND 9.11.5-S6\n+    BIND 9.11.6-S1"
        }
      ],
      "source": {
        "discovery": "USER"
      },
      "title": "BIND Supported Preview Edition can exit with an assertion failure if nxdomain-redirect is used",
      "workarounds": [
        {
          "lang": "en",
          "value": "Exploitation of this defect can be effectively prevented by disabling the nxdomain-redirect feature in the nameserver\u0027s configuration."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-officer@isc.org",
          "DATE_PUBLIC": "2019-04-24T23:00:00.000Z",
          "ID": "CVE-2019-6468",
          "STATE": "PUBLIC",
          "TITLE": "BIND Supported Preview Edition can exit with an assertion failure if nxdomain-redirect is used"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIND 9 Supported Preview Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "BIND 9",
                            "version_value": "9.10.5-S1 -\u003e 9.11.5-S5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ISC"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "ISC would like to thank Quad9 for reporting this issue."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In BIND Supported Preview Edition, an error in the nxdomain-redirect feature can occur in versions which support EDNS Client Subnet (ECS) features. In those versions which have ECS support, enabling nxdomain-redirect is likely to lead to BIND exiting due to assertion failure. Versions affected: BIND Supported Preview Edition version 9.10.5-S1 -\u003e 9.11.5-S5. ONLY BIND Supported Preview Edition releases are affected."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "If nxdomain-redirect is enabled (via configuration) in a vulnerable BIND release, a malicious party can cause BIND to exit by deliberately triggering the bug."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.isc.org/docs/cve-2019-6468",
              "refsource": "CONFIRM",
              "url": "https://kb.isc.org/docs/cve-2019-6468"
            },
            {
              "name": "https://www.synology.com/security/advisory/Synology_SA_19_20",
              "refsource": "CONFIRM",
              "url": "https://www.synology.com/security/advisory/Synology_SA_19_20"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Upgrade to the patched release most closely related to your current version of BIND:\n\nBIND Supported Preview Edition is a special feature preview branch of BIND provided to eligible ISC support customers.\n\n+    BIND 9.11.5-S6\n+    BIND 9.11.6-S1"
          }
        ],
        "source": {
          "discovery": "USER"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Exploitation of this defect can be effectively prevented by disabling the nxdomain-redirect feature in the nameserver\u0027s configuration."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "404fd4d2-a609-4245-b543-2c944a302a22",
    "assignerShortName": "isc",
    "cveId": "CVE-2019-6468",
    "datePublished": "2019-10-09T14:17:14.488494Z",
    "dateReserved": "2019-01-16T00:00:00",
    "dateUpdated": "2024-09-16T18:44:17.039Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-6469
Vulnerability from cvelistv5
Published
2019-10-09 14:17
Modified
2024-09-17 01:30
Summary
BIND Supported Preview Edition can exit with an assertion failure if ECS is in use
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:20.909Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.isc.org/docs/cve-2019-6469"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.f5.com/csp/article/K39751401?utm_source=f5support\u0026amp%3Butm_medium=RSS"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIND 9 Supported Preview Edition",
          "vendor": "ISC",
          "versions": [
            {
              "status": "affected",
              "version": "BIND 9.10.5-S1 -\u003e 9.11.6-S1 of BIND 9 Supported Preview Edition."
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "ISC would like to thank Quad9 for reporting this issue."
        }
      ],
      "datePublic": "2019-05-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An error in the EDNS Client Subnet (ECS) feature for recursive resolvers can cause BIND to exit with an assertion failure when processing a response that has malformed RRSIGs. Versions affected: BIND 9.10.5-S1 -\u003e 9.11.6-S1 of BIND 9 Supported Preview Edition."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "An attacker who is able to cause a server to perform a query whose answer will be accompanied by malformed RRSIGs can deliberately cause a server to exit if it is using the recursive ECS feature.",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-02T02:06:16",
        "orgId": "404fd4d2-a609-4245-b543-2c944a302a22",
        "shortName": "isc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.isc.org/docs/cve-2019-6469"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.f5.com/csp/article/K39751401?utm_source=f5support\u0026amp%3Butm_medium=RSS"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to the patched release most closely related to your current version of BIND:\n\nBIND Supported Preview Edition is a special feature preview branch of BIND provided to eligible ISC support customers.\n\n\u003e=    BIND 9.11.7-S1"
        }
      ],
      "source": {
        "discovery": "USER"
      },
      "title": "BIND Supported Preview Edition can exit with an assertion failure if ECS is in use",
      "workarounds": [
        {
          "lang": "en",
          "value": "Only servers which have enabled the EDNS Client Subnet (ECS) feature can be affected by this defect; it can be prevented by disabling ECS options in the server\u0027s configuration."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-officer@isc.org",
          "DATE_PUBLIC": "2019-05-29T23:00:00.000Z",
          "ID": "CVE-2019-6469",
          "STATE": "PUBLIC",
          "TITLE": "BIND Supported Preview Edition can exit with an assertion failure if ECS is in use"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIND 9 Supported Preview Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "BIND 9",
                            "version_value": "BIND 9.10.5-S1 -\u003e 9.11.6-S1 of BIND 9 Supported Preview Edition."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ISC"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "ISC would like to thank Quad9 for reporting this issue."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An error in the EDNS Client Subnet (ECS) feature for recursive resolvers can cause BIND to exit with an assertion failure when processing a response that has malformed RRSIGs. Versions affected: BIND 9.10.5-S1 -\u003e 9.11.6-S1 of BIND 9 Supported Preview Edition."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "An attacker who is able to cause a server to perform a query whose answer will be accompanied by malformed RRSIGs can deliberately cause a server to exit if it is using the recursive ECS feature."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.isc.org/docs/cve-2019-6469",
              "refsource": "CONFIRM",
              "url": "https://kb.isc.org/docs/cve-2019-6469"
            },
            {
              "name": "https://support.f5.com/csp/article/K39751401?utm_source=f5support\u0026amp;utm_medium=RSS",
              "refsource": "CONFIRM",
              "url": "https://support.f5.com/csp/article/K39751401?utm_source=f5support\u0026amp;utm_medium=RSS"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Upgrade to the patched release most closely related to your current version of BIND:\n\nBIND Supported Preview Edition is a special feature preview branch of BIND provided to eligible ISC support customers.\n\n\u003e=    BIND 9.11.7-S1"
          }
        ],
        "source": {
          "discovery": "USER"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Only servers which have enabled the EDNS Client Subnet (ECS) feature can be affected by this defect; it can be prevented by disabling ECS options in the server\u0027s configuration."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "404fd4d2-a609-4245-b543-2c944a302a22",
    "assignerShortName": "isc",
    "cveId": "CVE-2019-6469",
    "datePublished": "2019-10-09T14:17:14.528095Z",
    "dateReserved": "2019-01-16T00:00:00",
    "dateUpdated": "2024-09-17T01:30:59.645Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}