All the vulnerabilites related to Dell - BIOSConnect
cve-2021-21573
Vulnerability from cvelistv5
Published
2021-06-24 17:00
Modified
2024-09-17 01:11
Summary
Dell BIOSConnect feature contains a buffer overflow vulnerability. An authenticated malicious admin user with local access to the system may potentially exploit this vulnerability to run arbitrary code and bypass UEFI restrictions.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.393Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000188682"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIOSConnect",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Gen 11, Gen 10",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-06-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell BIOSConnect feature contains a buffer overflow vulnerability. An authenticated malicious admin user with local access to the system may potentially exploit this vulnerability to run arbitrary code and bypass UEFI restrictions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-24T17:00:18",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000188682"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-06-24",
          "ID": "CVE-2021-21573",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIOSConnect",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Gen 11, Gen 10"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell BIOSConnect feature contains a buffer overflow vulnerability. An authenticated malicious admin user with local access to the system may potentially exploit this vulnerability to run arbitrary code and bypass UEFI restrictions."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000188682",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000188682"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21573",
    "datePublished": "2021-06-24T17:00:18.090009Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-17T01:11:41.809Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-21572
Vulnerability from cvelistv5
Published
2021-06-24 17:00
Modified
2024-09-16 19:30
Summary
Dell BIOSConnect feature contains a buffer overflow vulnerability. An authenticated malicious admin user with local access to the system may potentially exploit this vulnerability to run arbitrary code and bypass UEFI restrictions.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.404Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000188682"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIOSConnect",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Gen 11, Gen 10",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-06-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell BIOSConnect feature contains a buffer overflow vulnerability. An authenticated malicious admin user with local access to the system may potentially exploit this vulnerability to run arbitrary code and bypass UEFI restrictions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-24T17:00:16",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000188682"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-06-24",
          "ID": "CVE-2021-21572",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIOSConnect",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Gen 11, Gen 10"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell BIOSConnect feature contains a buffer overflow vulnerability. An authenticated malicious admin user with local access to the system may potentially exploit this vulnerability to run arbitrary code and bypass UEFI restrictions."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122: Heap-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000188682",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000188682"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21572",
    "datePublished": "2021-06-24T17:00:16.600794Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-16T19:30:31.142Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-21574
Vulnerability from cvelistv5
Published
2021-06-24 17:00
Modified
2024-09-16 21:08
Summary
Dell BIOSConnect feature contains a buffer overflow vulnerability. An authenticated malicious admin user with local access to the system may potentially exploit this vulnerability to run arbitrary code and bypass UEFI restrictions.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.464Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000188682"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BIOSConnect",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "Gen 11, Gen 10",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-06-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell BIOSConnect feature contains a buffer overflow vulnerability. An authenticated malicious admin user with local access to the system may potentially exploit this vulnerability to run arbitrary code and bypass UEFI restrictions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-24T17:00:19",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000188682"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-06-24",
          "ID": "CVE-2021-21574",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BIOSConnect",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Gen 11, Gen 10"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell BIOSConnect feature contains a buffer overflow vulnerability. An authenticated malicious admin user with local access to the system may potentially exploit this vulnerability to run arbitrary code and bypass UEFI restrictions."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000188682",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000188682"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21574",
    "datePublished": "2021-06-24T17:00:19.574722Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-16T21:08:05.986Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}