CVE-2025-58319 (GCVE-0-2025-58319)
Vulnerability from cvelistv5 – Published: 2025-09-24 06:42 – Updated: 2025-09-24 13:10
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
7.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , < 2.1.0.34
(custom)
|
Credits
Jessie Cooper of CISA
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-58319",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-24T13:09:42.496667Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-24T13:10:05.302Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThan": "2.1.0.34",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "coordinator",
"value": "Jessie Cooper of CISA"
}
],
"datePublic": "2025-09-24T06:02:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-24T06:42:08.525Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00017_CNCSoft-G2_File%20Parsing%20Stack-based%20Buffer%20Overflow%20Vulnerability.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Download and update to: v2.1.0.34 or later\u003cbr\u003e"
}
],
"value": "Download and update to: v2.1.0.34 or later"
}
],
"source": {
"defect": [
"CISA"
],
"discovery": "EXTERNAL"
},
"title": "File Parsing Memory Corruption in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-58319",
"datePublished": "2025-09-24T06:42:08.525Z",
"dateReserved": "2025-08-28T06:15:58.626Z",
"dateUpdated": "2025-09-24T13:10:05.302Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-58317 (GCVE-0-2025-58317)
Vulnerability from cvelistv5 – Published: 2025-09-24 06:38 – Updated: 2025-09-24 13:13
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
7.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , < 2.1.0.34
(custom)
|
Credits
Natnael Samson working with Trend Micro Zero Day Initiative
Jason Forbush of CISA
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-58317",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-24T13:13:22.686691Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-24T13:13:34.500Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThan": "2.1.0.34",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Natnael Samson working with Trend Micro Zero Day Initiative"
},
{
"lang": "en",
"type": "coordinator",
"value": "Jason Forbush of CISA"
}
],
"datePublic": "2025-09-24T06:02:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-24T06:38:43.161Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00017_CNCSoft-G2_File%20Parsing%20Stack-based%20Buffer%20Overflow%20Vulnerability.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Download and update to: v2.1.0.34 or later\u003cbr\u003e"
}
],
"value": "Download and update to: v2.1.0.34 or later"
}
],
"source": {
"defect": [
"CISA"
],
"discovery": "EXTERNAL"
},
"title": "File Parsing Memory Corruption in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-58317",
"datePublished": "2025-09-24T06:38:43.161Z",
"dateReserved": "2025-08-28T06:15:58.626Z",
"dateUpdated": "2025-09-24T13:13:34.500Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-47728 (GCVE-0-2025-47728)
Vulnerability from cvelistv5 – Published: 2025-06-04 08:11 – Updated: 2025-08-27 01:03
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , < 2.1.0.27
(custom)
|
Credits
Kholoud Altookhy from Trend Micro's Zero Day Initiative
Jason Forbush of CISA
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47728",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-04T13:26:47.796513Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-04T13:26:55.450Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThan": "2.1.0.27",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Kholoud Altookhy from Trend Micro\u0027s Zero Day Initiative"
},
{
"lang": "en",
"type": "coordinator",
"value": "Jason Forbush of CISA"
}
],
"datePublic": "2025-06-04T08:05:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T01:03:04.682Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00007_CNCSoft-G2%20-%20File%20Parsing%20Memory%20Corruption.pdf"
}
],
"source": {
"defect": [
"CISA"
],
"discovery": "EXTERNAL"
},
"title": "File Parsing Memory Corruption in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-47728",
"datePublished": "2025-06-04T08:11:06.007Z",
"dateReserved": "2025-05-08T08:08:01.077Z",
"dateUpdated": "2025-08-27T01:03:04.682Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-12858 (GCVE-0-2024-12858)
Vulnerability from cvelistv5 – Published: 2025-03-13 16:47 – Updated: 2025-04-02 15:02
VLAI?
This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. *** Duplicate of CVE-2025-22880 ***
Show details on NVD website{
"containers": {
"cna": {
"providerMetadata": {
"dateUpdated": "2025-04-02T15:02:50.433Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"rejectedReasons": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.\u003cbr\u003e*** Duplicate of \nCVE-2025-22880\n\n***"
}
],
"value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.\n*** Duplicate of \nCVE-2025-22880\n\n***"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-12858",
"datePublished": "2025-03-13T16:47:43.636Z",
"dateRejected": "2025-04-02T15:02:50.433Z",
"dateReserved": "2024-12-20T16:52:15.306Z",
"dateUpdated": "2025-04-02T15:02:50.433Z",
"state": "REJECTED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-22881 (GCVE-0-2025-22881)
Vulnerability from cvelistv5 – Published: 2025-02-26 01:44 – Updated: 2025-02-26 15:43
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , ≤ 2.1.0.10
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-22881",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T14:49:19.074255Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T15:43:08.047Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "2.1.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-02-26T01:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-44",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-44 Overflow Binary Resource File"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T01:44:17.551Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00003_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Heap-based Buffer Overflow in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-22881",
"datePublished": "2025-02-26T01:44:17.551Z",
"dateReserved": "2025-01-09T03:48:26.774Z",
"dateUpdated": "2025-02-26T15:43:08.047Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-22880 (GCVE-0-2025-22880)
Vulnerability from cvelistv5 – Published: 2025-02-07 07:26 – Updated: 2025-02-07 15:54
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
7.8 (High)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , < 2.1.0.20
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-22880",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T15:49:27.000208Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T15:54:27.041Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThan": "2.1.0.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-02-07T07:20:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-44",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-44 Overflow Binary Resource File"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T07:26:04.691Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00002_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2024-09-28T06:24:00.000Z",
"value": "Reported"
},
{
"lang": "en",
"time": "2024-12-04T06:26:00.000Z",
"value": "New patch (CNCSoft-G2 v2.1.0.20) released"
}
],
"title": "Heap-based Buffer Overflow in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-22880",
"datePublished": "2025-02-07T07:26:04.691Z",
"dateReserved": "2025-01-09T03:48:26.774Z",
"dateUpdated": "2025-02-07T15:54:27.041Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47966 (GCVE-0-2024-47966)
Vulnerability from cvelistv5 – Published: 2024-10-10 17:18 – Updated: 2024-10-10 17:37
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-457 - Use of Uninitialized Variable
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47966",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:35:10.512564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:37:04.833Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-457",
"description": "CWE-457 Use of Uninitialized Variable",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:18:58.817Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Use of Uninitialized Variable vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47966",
"datePublished": "2024-10-10T17:18:58.817Z",
"dateReserved": "2024-10-07T17:01:16.643Z",
"dateUpdated": "2024-10-10T17:37:04.833Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47965 (GCVE-0-2024-47965)
Vulnerability from cvelistv5 – Published: 2024-10-10 17:18 – Updated: 2024-10-10 17:41
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47965",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:40:16.943724Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:41:01.289Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:18:01.407Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Read vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47965",
"datePublished": "2024-10-10T17:18:01.407Z",
"dateReserved": "2024-10-07T17:01:16.642Z",
"dateUpdated": "2024-10-10T17:41:01.289Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47964 (GCVE-0-2024-47964)
Vulnerability from cvelistv5 – Published: 2024-10-10 17:16 – Updated: 2024-10-10 17:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47964",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:41:41.260226Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:42:30.381Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:16:51.747Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47964",
"datePublished": "2024-10-10T17:16:51.747Z",
"dateReserved": "2024-10-07T17:01:16.642Z",
"dateUpdated": "2024-10-10T17:42:30.381Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47963 (GCVE-0-2024-47963)
Vulnerability from cvelistv5 – Published: 2024-10-10 17:15 – Updated: 2024-10-10 17:43
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47963",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:43:14.190343Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:43:56.182Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:15:54.044Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Write vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47963",
"datePublished": "2024-10-10T17:15:54.044Z",
"dateReserved": "2024-10-07T17:01:16.642Z",
"dateUpdated": "2024-10-10T17:43:56.182Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47962 (GCVE-0-2024-47962)
Vulnerability from cvelistv5 – Published: 2024-10-10 17:14 – Updated: 2024-10-10 17:45
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47962",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:44:29.384286Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:45:02.444Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:14:30.805Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Stack-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47962",
"datePublished": "2024-10-10T17:14:30.805Z",
"dateReserved": "2024-10-07T17:01:16.642Z",
"dateUpdated": "2024-10-10T17:45:02.444Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39883 (GCVE-0-2024-39883)
Vulnerability from cvelistv5 – Published: 2024-07-09 21:25 – Updated: 2025-08-27 20:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.0.0.5
|
Credits
Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39883",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T14:24:25.123528Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:58.407Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:11.201Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T21:25:49.165Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap-based Buffer Overflow in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-39883",
"datePublished": "2024-07-09T21:25:49.165Z",
"dateReserved": "2024-07-01T18:13:23.097Z",
"dateUpdated": "2025-08-27T20:42:58.407Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39882 (GCVE-0-2024-39882)
Vulnerability from cvelistv5 – Published: 2024-07-09 21:25 – Updated: 2025-08-27 20:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.0.0.5
|
Credits
Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39882",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T18:55:11.251122Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:58.211Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:10.314Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T21:25:02.237Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Read in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-39882",
"datePublished": "2024-07-09T21:25:02.237Z",
"dateReserved": "2024-07-01T18:13:23.097Z",
"dateUpdated": "2025-08-27T20:42:58.211Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39881 (GCVE-0-2024-39881)
Vulnerability from cvelistv5 – Published: 2024-07-09 21:23 – Updated: 2025-08-27 20:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.0.0.5
|
Credits
Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39881",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-10T15:22:25.578143Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:58.039Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:11.245Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T21:23:31.171Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Write in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-39881",
"datePublished": "2024-07-09T21:23:31.171Z",
"dateReserved": "2024-07-01T18:13:23.097Z",
"dateUpdated": "2025-08-27T20:42:58.039Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39880 (GCVE-0-2024-39880)
Vulnerability from cvelistv5 – Published: 2024-07-09 21:21 – Updated: 2025-08-27 20:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.0.0.5
|
Credits
Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39880",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-10T13:58:44.937267Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:57.877Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:11.485Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T23:12:00.978Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Stack-based Buffer Overflow in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-39880",
"datePublished": "2024-07-09T21:21:47.678Z",
"dateReserved": "2024-07-01T18:13:23.097Z",
"dateUpdated": "2025-08-27T20:42:57.877Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-58319 (GCVE-0-2025-58319)
Vulnerability from nvd – Published: 2025-09-24 06:42 – Updated: 2025-09-24 13:10
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
7.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , < 2.1.0.34
(custom)
|
Credits
Jessie Cooper of CISA
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-58319",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-24T13:09:42.496667Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-24T13:10:05.302Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThan": "2.1.0.34",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "coordinator",
"value": "Jessie Cooper of CISA"
}
],
"datePublic": "2025-09-24T06:02:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-24T06:42:08.525Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00017_CNCSoft-G2_File%20Parsing%20Stack-based%20Buffer%20Overflow%20Vulnerability.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Download and update to: v2.1.0.34 or later\u003cbr\u003e"
}
],
"value": "Download and update to: v2.1.0.34 or later"
}
],
"source": {
"defect": [
"CISA"
],
"discovery": "EXTERNAL"
},
"title": "File Parsing Memory Corruption in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-58319",
"datePublished": "2025-09-24T06:42:08.525Z",
"dateReserved": "2025-08-28T06:15:58.626Z",
"dateUpdated": "2025-09-24T13:10:05.302Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-58317 (GCVE-0-2025-58317)
Vulnerability from nvd – Published: 2025-09-24 06:38 – Updated: 2025-09-24 13:13
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
7.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , < 2.1.0.34
(custom)
|
Credits
Natnael Samson working with Trend Micro Zero Day Initiative
Jason Forbush of CISA
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-58317",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-24T13:13:22.686691Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-24T13:13:34.500Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThan": "2.1.0.34",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Natnael Samson working with Trend Micro Zero Day Initiative"
},
{
"lang": "en",
"type": "coordinator",
"value": "Jason Forbush of CISA"
}
],
"datePublic": "2025-09-24T06:02:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-24T06:38:43.161Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00017_CNCSoft-G2_File%20Parsing%20Stack-based%20Buffer%20Overflow%20Vulnerability.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Download and update to: v2.1.0.34 or later\u003cbr\u003e"
}
],
"value": "Download and update to: v2.1.0.34 or later"
}
],
"source": {
"defect": [
"CISA"
],
"discovery": "EXTERNAL"
},
"title": "File Parsing Memory Corruption in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-58317",
"datePublished": "2025-09-24T06:38:43.161Z",
"dateReserved": "2025-08-28T06:15:58.626Z",
"dateUpdated": "2025-09-24T13:13:34.500Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-47728 (GCVE-0-2025-47728)
Vulnerability from nvd – Published: 2025-06-04 08:11 – Updated: 2025-08-27 01:03
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , < 2.1.0.27
(custom)
|
Credits
Kholoud Altookhy from Trend Micro's Zero Day Initiative
Jason Forbush of CISA
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47728",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-04T13:26:47.796513Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-04T13:26:55.450Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThan": "2.1.0.27",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Kholoud Altookhy from Trend Micro\u0027s Zero Day Initiative"
},
{
"lang": "en",
"type": "coordinator",
"value": "Jason Forbush of CISA"
}
],
"datePublic": "2025-06-04T08:05:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cstrong\u003eDelta Electronics CNCSoft-G2\u003c/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2\u00a0lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T01:03:04.682Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00007_CNCSoft-G2%20-%20File%20Parsing%20Memory%20Corruption.pdf"
}
],
"source": {
"defect": [
"CISA"
],
"discovery": "EXTERNAL"
},
"title": "File Parsing Memory Corruption in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-47728",
"datePublished": "2025-06-04T08:11:06.007Z",
"dateReserved": "2025-05-08T08:08:01.077Z",
"dateUpdated": "2025-08-27T01:03:04.682Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-12858 (GCVE-0-2024-12858)
Vulnerability from nvd – Published: 2025-03-13 16:47 – Updated: 2025-04-02 15:02
VLAI?
This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. *** Duplicate of CVE-2025-22880 ***
Show details on NVD website{
"containers": {
"cna": {
"providerMetadata": {
"dateUpdated": "2025-04-02T15:02:50.433Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"rejectedReasons": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.\u003cbr\u003e*** Duplicate of \nCVE-2025-22880\n\n***"
}
],
"value": "This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.\n*** Duplicate of \nCVE-2025-22880\n\n***"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-12858",
"datePublished": "2025-03-13T16:47:43.636Z",
"dateRejected": "2025-04-02T15:02:50.433Z",
"dateReserved": "2024-12-20T16:52:15.306Z",
"dateUpdated": "2025-04-02T15:02:50.433Z",
"state": "REJECTED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-22881 (GCVE-0-2025-22881)
Vulnerability from nvd – Published: 2025-02-26 01:44 – Updated: 2025-02-26 15:43
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , ≤ 2.1.0.10
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-22881",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T14:49:19.074255Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T15:43:08.047Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThanOrEqual": "2.1.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-02-26T01:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-44",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-44 Overflow Binary Resource File"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T01:44:17.551Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00003_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Heap-based Buffer Overflow in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-22881",
"datePublished": "2025-02-26T01:44:17.551Z",
"dateReserved": "2025-01-09T03:48:26.774Z",
"dateUpdated": "2025-02-26T15:43:08.047Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-22880 (GCVE-0-2025-22880)
Vulnerability from nvd – Published: 2025-02-07 07:26 – Updated: 2025-02-07 15:54
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
7.8 (High)
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
0 , < 2.1.0.20
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-22880",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T15:49:27.000208Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T15:54:27.041Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"lessThan": "2.1.0.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-02-07T07:20:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"impacts": [
{
"capecId": "CAPEC-44",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-44 Overflow Binary Resource File"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T07:26:04.691Z",
"orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"shortName": "Deltaww"
},
"references": [
{
"url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00002_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2024-09-28T06:24:00.000Z",
"value": "Reported"
},
{
"lang": "en",
"time": "2024-12-04T06:26:00.000Z",
"value": "New patch (CNCSoft-G2 v2.1.0.20) released"
}
],
"title": "Heap-based Buffer Overflow in CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"assignerShortName": "Deltaww",
"cveId": "CVE-2025-22880",
"datePublished": "2025-02-07T07:26:04.691Z",
"dateReserved": "2025-01-09T03:48:26.774Z",
"dateUpdated": "2025-02-07T15:54:27.041Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47966 (GCVE-0-2024-47966)
Vulnerability from nvd – Published: 2024-10-10 17:18 – Updated: 2024-10-10 17:37
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-457 - Use of Uninitialized Variable
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47966",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:35:10.512564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:37:04.833Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper initialization of memory prior to accessing it. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-457",
"description": "CWE-457 Use of Uninitialized Variable",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:18:58.817Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Use of Uninitialized Variable vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47966",
"datePublished": "2024-10-10T17:18:58.817Z",
"dateReserved": "2024-10-07T17:01:16.643Z",
"dateUpdated": "2024-10-10T17:37:04.833Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47965 (GCVE-0-2024-47965)
Vulnerability from nvd – Published: 2024-10-10 17:18 – Updated: 2024-10-10 17:41
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47965",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:40:16.943724Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:41:01.289Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:18:01.407Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Read vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47965",
"datePublished": "2024-10-10T17:18:01.407Z",
"dateReserved": "2024-10-07T17:01:16.642Z",
"dateUpdated": "2024-10-10T17:41:01.289Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47964 (GCVE-0-2024-47964)
Vulnerability from nvd – Published: 2024-10-10 17:16 – Updated: 2024-10-10 17:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47964",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:41:41.260226Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:42:30.381Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:16:51.747Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47964",
"datePublished": "2024-10-10T17:16:51.747Z",
"dateReserved": "2024-10-07T17:01:16.642Z",
"dateUpdated": "2024-10-10T17:42:30.381Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47963 (GCVE-0-2024-47963)
Vulnerability from nvd – Published: 2024-10-10 17:15 – Updated: 2024-10-10 17:43
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47963",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:43:14.190343Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:43:56.182Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:15:54.044Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Write vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47963",
"datePublished": "2024-10-10T17:15:54.044Z",
"dateReserved": "2024-10-07T17:01:16.642Z",
"dateUpdated": "2024-10-10T17:43:56.182Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-47962 (GCVE-0-2024-47962)
Vulnerability from nvd – Published: 2024-10-10 17:14 – Updated: 2024-10-10 17:45
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.1.0.10
|
Credits
Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-47962",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-10T17:44:29.384286Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:45:02.444Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.1.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould, Fritz Sands, and Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can manipulate an insider to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-10T17:14:30.805Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=CNCSoft-g2\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 v2.1.0.16\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.16 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Stack-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-47962",
"datePublished": "2024-10-10T17:14:30.805Z",
"dateReserved": "2024-10-07T17:01:16.642Z",
"dateUpdated": "2024-10-10T17:45:02.444Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39883 (GCVE-0-2024-39883)
Vulnerability from nvd – Published: 2024-07-09 21:25 – Updated: 2025-08-27 20:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.0.0.5
|
Credits
Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39883",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-11T14:24:25.123528Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:58.407Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:11.201Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T21:25:49.165Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Heap-based Buffer Overflow in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-39883",
"datePublished": "2024-07-09T21:25:49.165Z",
"dateReserved": "2024-07-01T18:13:23.097Z",
"dateUpdated": "2025-08-27T20:42:58.407Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39882 (GCVE-0-2024-39882)
Vulnerability from nvd – Published: 2024-07-09 21:25 – Updated: 2025-08-27 20:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.0.0.5
|
Credits
Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39882",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T18:55:11.251122Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:58.211Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:10.314Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T21:25:02.237Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Read in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-39882",
"datePublished": "2024-07-09T21:25:02.237Z",
"dateReserved": "2024-07-01T18:13:23.097Z",
"dateUpdated": "2025-08-27T20:42:58.211Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39881 (GCVE-0-2024-39881)
Vulnerability from nvd – Published: 2024-07-09 21:23 – Updated: 2025-08-27 20:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.0.0.5
|
Credits
Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39881",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-10T15:22:25.578143Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:58.039Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:11.245Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a memory corruption condition. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T21:23:31.171Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Write in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-39881",
"datePublished": "2024-07-09T21:23:31.171Z",
"dateReserved": "2024-07-01T18:13:23.097Z",
"dateUpdated": "2025-08-27T20:42:58.039Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39880 (GCVE-0-2024-39880)
Vulnerability from nvd – Published: 2024-07-09 21:21 – Updated: 2025-08-27 20:42
VLAI?
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Delta Electronics | CNCSoft-G2 |
Affected:
2.0.0.5
|
Credits
Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "cncsoft-g2",
"vendor": "delta_electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39880",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-10T13:58:44.937267Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:42:57.877Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T04:33:11.485Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CNCSoft-G2",
"vendor": "Delta Electronics",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Bobby Gould and Fritz Sands of Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\u003c/span\u003e"
}
],
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T23:12:00.978Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.10\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Delta Electronics recommends users update to CNCSoft-G2 V2.1.0.10 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Stack-based Buffer Overflow in Delta Electronics CNCSoft-G2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-39880",
"datePublished": "2024-07-09T21:21:47.678Z",
"dateReserved": "2024-07-01T18:13:23.097Z",
"dateUpdated": "2025-08-27T20:42:57.877Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}