All the vulnerabilites related to Contec - CONPROSYS HMI System
cve-2023-2758
Vulnerability from cvelistv5
Published
2023-05-31 14:09
Modified
2024-08-02 06:33
Severity ?
EPSS score ?
Summary
Contec CONPROSYS HMI System (CHS) v3.5.2 Denial of Service
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Contec | CONPROSYS HMI System |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T06:33:05.476Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2023-21" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU93372935/index.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CONPROSYS HMI System", "vendor": "Contec", "versions": [ { "lessThanOrEqual": "3.5.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "datePublic": "2023-05-31T14:08:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time." } ], "value": "A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 3.7, "baseSeverity": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-799", "description": "CWE-799", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-31T14:09:49.809Z", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "url": "https://www.tenable.com/security/research/tra-2023-21" }, { "url": "https://jvn.jp/en/vu/JVNVU93372935/index.html" } ], "source": { "discovery": "UNKNOWN" }, "title": "Contec CONPROSYS HMI System (CHS) v3.5.2 Denial of Service", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2023-2758", "datePublished": "2023-05-31T14:09:49.809Z", "dateReserved": "2023-05-17T12:46:36.673Z", "dateUpdated": "2024-08-02T06:33:05.476Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }