All the vulnerabilites related to Schneider Electric - EcoStruxure Power Design - Ecodial
cve-2024-2229
Vulnerability from cvelistv5
Published
2024-03-18 16:08
Modified
2024-08-01 19:03
Severity ?
EPSS score ?
Summary
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code
execution when a malicious project file is loaded into the application by a valid user.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Schneider Electric | EcoStruxure Power Design - Ecodial |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ecostruxure_power_monitoring_expert", "vendor": "schneider-electric", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2229", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-03-18T16:27:40.910097Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-20T20:59:48.954Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:03:39.361Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-072-02.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure Power Design - Ecodial", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions NL" }, { "status": "affected", "version": "All Versions INT" }, { "status": "affected", "version": "All Versions FR" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\n\n\n\n\nCWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code\nexecution when a malicious project file is loaded into the application by a valid user.\n\n\n\n\n\n\n\n" } ], "value": "\nCWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code\nexecution when a malicious project file is loaded into the application by a valid user.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-18T16:08:33.773Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-072-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2024-2229", "datePublished": "2024-03-18T16:08:33.773Z", "dateReserved": "2024-03-06T17:07:33.392Z", "dateUpdated": "2024-08-01T19:03:39.361Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }