All the vulnerabilites related to Schneider Electric - EcoStruxure Power Monitoring Expert (PME)
cve-2023-5986
Vulnerability from cvelistv5
Published
2023-11-15 03:47
Modified
2024-08-02 08:14
Severity ?
EPSS score ?
Summary
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input
attackers can cause the software’s web application to redirect to the chosen domain after a
successful login is performed.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:14:25.141Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure Power Monitoring Expert (PME)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2020 CU2 and prior" }, { "status": "affected", "version": "Version 2021 CU1 and prior" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021" }, { "status": "affected", "version": "Advanced Reporting and Dashboards Module 2020 prior to CU3" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n" } ], "value": "\nA CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input\nattackers can cause the software\u2019s web application to redirect to the chosen domain after a\nsuccessful login is performed. \n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-601", "description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-15T03:47:17.684Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-5986", "datePublished": "2023-11-15T03:47:17.684Z", "dateReserved": "2023-11-07T10:57:54.715Z", "dateUpdated": "2024-08-02T08:14:25.141Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-9005
Vulnerability from cvelistv5
Published
2024-10-08 10:22
Modified
2024-10-08 13:46
Severity ?
EPSS score ?
Summary
CWE-502: Deserialization of Untrusted Data vulnerability exists that could allow code to be
remotely executed on the server when unsafely deserialized data is posted to the web server.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Schneider Electric | EcoStruxure Power Monitoring Expert (PME) |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:schneider_electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ecostruxure_power_monitoring_expert", "vendor": "schneider_electric", "versions": [ { "lessThan": "2022", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-9005", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-08T13:41:43.580145Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-08T13:46:49.267Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure Power Monitoring Expert (PME)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2022 and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-502: Deserialization of Untrusted Data vulnerability exists that could allow code to be\nremotely executed on the server when unsafely deserialized data is posted to the web server." } ], "value": "CWE-502: Deserialization of Untrusted Data vulnerability exists that could allow code to be\nremotely executed on the server when unsafely deserialized data is posted to the web server." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T10:22:06.939Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-05.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2024-9005", "datePublished": "2024-10-08T10:22:06.939Z", "dateReserved": "2024-09-19T14:52:15.415Z", "dateUpdated": "2024-10-08T13:46:49.267Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-5987
Vulnerability from cvelistv5
Published
2023-11-15 03:48
Modified
2024-08-02 08:14
Severity ?
EPSS score ?
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)
vulnerability that could cause a vulnerability leading to a cross site scripting condition where
attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing
the injected payload.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:14:25.122Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure Power Monitoring Expert (PME)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2020 CU2 and prior" }, { "status": "affected", "version": "Version 2021 CU1 and prior" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure Power Operation (EPO) \u2013 Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021" }, { "status": "affected", "version": "Advanced Reporting and Dashboards Module 2020 prior to CU3" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n" } ], "value": "\nA CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)\nvulnerability that could cause a vulnerability leading to a cross site scripting condition where\nattackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a page containing\nthe injected payload.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-15T03:48:50.993Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-318-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-5987", "datePublished": "2023-11-15T03:48:50.993Z", "dateReserved": "2023-11-07T10:58:51.030Z", "dateUpdated": "2024-08-02T08:14:25.122Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }