cve-2018-1171
Vulnerability from cvelistv5
Published
2018-03-19 18:00
Modified
2024-08-05 03:51
Severity ?
EPSS score ?
Summary
This vulnerability allows local attackers to escalate privileges on vulnerable installations of Joyent SmartOS release-20170803-20170803T064301Z. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the DTrace DOF files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can leverage this vulnerability to execute code under the context of the host OS. Was ZDI-CAN-5106.
References
▼ | URL | Tags |
---|---|---|
https://help.joyent.com/hc/en-us/articles/360000608188 | x_refsource_CONFIRM | |
http://www.oracle.com/technetwork/security-advisory/cpujul2018-4258247.html | x_refsource_CONFIRM | |
http://www.securitytracker.com/id/1041303 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/104799 | vdb-entry, x_refsource_BID | |
https://zerodayinitiative.com/advisories/ZDI-18-236 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Joyent | Joyent SmartOS |
Version: release-20170803-20170803T064301Z |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T03:51:49.003Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://help.joyent.com/hc/en-us/articles/360000608188" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2018-4258247.html" }, { "name": "1041303", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1041303" }, { "name": "104799", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104799" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-236" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Joyent SmartOS", "vendor": "Joyent", "versions": [ { "status": "affected", "version": "release-20170803-20170803T064301Z" } ] } ], "datePublic": "2017-03-07T00:00:00", "descriptions": [ { "lang": "en", "value": "This vulnerability allows local attackers to escalate privileges on vulnerable installations of Joyent SmartOS release-20170803-20170803T064301Z. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the DTrace DOF files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can leverage this vulnerability to execute code under the context of the host OS. Was ZDI-CAN-5106." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787-Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-27T09:57:01", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://help.joyent.com/hc/en-us/articles/360000608188" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2018-4258247.html" }, { "name": "1041303", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1041303" }, { "name": "104799", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104799" }, { "tags": [ "x_refsource_MISC" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-236" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "zdi-disclosures@trendmicro.com", "ID": "CVE-2018-1171", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Joyent SmartOS", "version": { "version_data": [ { "version_value": "release-20170803-20170803T064301Z" } ] } } ] }, "vendor_name": "Joyent" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "This vulnerability allows local attackers to escalate privileges on vulnerable installations of Joyent SmartOS release-20170803-20170803T064301Z. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the DTrace DOF files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can leverage this vulnerability to execute code under the context of the host OS. Was ZDI-CAN-5106." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-787-Out-of-bounds Write" } ] } ] }, "references": { "reference_data": [ { "name": "https://help.joyent.com/hc/en-us/articles/360000608188", "refsource": "CONFIRM", "url": "https://help.joyent.com/hc/en-us/articles/360000608188" }, { "name": "http://www.oracle.com/technetwork/security-advisory/cpujul2018-4258247.html", "refsource": "CONFIRM", "url": "http://www.oracle.com/technetwork/security-advisory/cpujul2018-4258247.html" }, { "name": "1041303", "refsource": "SECTRACK", "url": "http://www.securitytracker.com/id/1041303" }, { "name": "104799", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104799" }, { "name": "https://zerodayinitiative.com/advisories/ZDI-18-236", "refsource": "MISC", "url": "https://zerodayinitiative.com/advisories/ZDI-18-236" } ] } } } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2018-1171", "datePublished": "2018-03-19T18:00:00", "dateReserved": "2017-12-05T00:00:00", "dateUpdated": "2024-08-05T03:51:49.003Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-1166
Vulnerability from cvelistv5
Published
2018-02-21 14:00
Modified
2024-08-05 03:51
Severity ?
EPSS score ?
Summary
This vulnerability allows local attackers to escalate privileges on vulnerable installations of Joyent SmartOS release-20170803-20170803T064301Z. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the SMBIOC_TREE_RELE ioctl. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code under the context of the host OS. Was ZDI-CAN-4984.
References
▼ | URL | Tags |
---|---|---|
https://help.joyent.com/hc/en-us/articles/360000124928 | x_refsource_CONFIRM | |
https://zerodayinitiative.com/advisories/ZDI-18-159 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Joyent | Joyent SmartOS |
Version: release-20170803-20170803T064301Z |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T03:51:48.929Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://help.joyent.com/hc/en-us/articles/360000124928" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-159" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Joyent SmartOS", "vendor": "Joyent", "versions": [ { "status": "affected", "version": "release-20170803-20170803T064301Z" } ] } ], "datePublic": "2018-01-26T00:00:00", "descriptions": [ { "lang": "en", "value": "This vulnerability allows local attackers to escalate privileges on vulnerable installations of Joyent SmartOS release-20170803-20170803T064301Z. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the SMBIOC_TREE_RELE ioctl. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code under the context of the host OS. Was ZDI-CAN-4984." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-416", "description": "CWE-416-Use After Free", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-02-21T13:57:01", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://help.joyent.com/hc/en-us/articles/360000124928" }, { "tags": [ "x_refsource_MISC" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-159" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "zdi-disclosures@trendmicro.com", "ID": "CVE-2018-1166", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Joyent SmartOS", "version": { "version_data": [ { "version_value": "release-20170803-20170803T064301Z" } ] } } ] }, "vendor_name": "Joyent" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "This vulnerability allows local attackers to escalate privileges on vulnerable installations of Joyent SmartOS release-20170803-20170803T064301Z. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the SMBIOC_TREE_RELE ioctl. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code under the context of the host OS. Was ZDI-CAN-4984." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-416-Use After Free" } ] } ] }, "references": { "reference_data": [ { "name": "https://help.joyent.com/hc/en-us/articles/360000124928", "refsource": "CONFIRM", "url": "https://help.joyent.com/hc/en-us/articles/360000124928" }, { "name": "https://zerodayinitiative.com/advisories/ZDI-18-159", "refsource": "MISC", "url": "https://zerodayinitiative.com/advisories/ZDI-18-159" } ] } } } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2018-1166", "datePublished": "2018-02-21T14:00:00", "dateReserved": "2017-12-05T00:00:00", "dateUpdated": "2024-08-05T03:51:48.929Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-1165
Vulnerability from cvelistv5
Published
2018-02-21 14:00
Modified
2024-08-05 03:51
Severity ?
EPSS score ?
Summary
This vulnerability allows local attackers to escalate privileges on vulnerable installations of Joyent SmartOS release-20170803-20170803T064301Z. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the SMB_IOC_SVCENUM IOCTL. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code under the context of the host OS. Was ZDI-CAN-4983.
References
▼ | URL | Tags |
---|---|---|
https://help.joyent.com/hc/en-us/articles/360000124928 | x_refsource_CONFIRM | |
https://zerodayinitiative.com/advisories/ZDI-18-158 | x_refsource_MISC | |
https://www.oracle.com/security-alerts/cpuapr2020.html | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Joyent | Joyent SmartOS |
Version: release-20170803-20170803T064301Z |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T03:51:48.985Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://help.joyent.com/hc/en-us/articles/360000124928" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-158" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2020.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Joyent SmartOS", "vendor": "Joyent", "versions": [ { "status": "affected", "version": "release-20170803-20170803T064301Z" } ] } ], "datePublic": "2018-01-26T00:00:00", "descriptions": [ { "lang": "en", "value": "This vulnerability allows local attackers to escalate privileges on vulnerable installations of Joyent SmartOS release-20170803-20170803T064301Z. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the SMB_IOC_SVCENUM IOCTL. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code under the context of the host OS. Was ZDI-CAN-4983." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122-Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-15T21:06:45", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://help.joyent.com/hc/en-us/articles/360000124928" }, { "tags": [ "x_refsource_MISC" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-158" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.oracle.com/security-alerts/cpuapr2020.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "zdi-disclosures@trendmicro.com", "ID": "CVE-2018-1165", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Joyent SmartOS", "version": { "version_data": [ { "version_value": "release-20170803-20170803T064301Z" } ] } } ] }, "vendor_name": "Joyent" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "This vulnerability allows local attackers to escalate privileges on vulnerable installations of Joyent SmartOS release-20170803-20170803T064301Z. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the SMB_IOC_SVCENUM IOCTL. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code under the context of the host OS. Was ZDI-CAN-4983." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122-Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://help.joyent.com/hc/en-us/articles/360000124928", "refsource": "CONFIRM", "url": "https://help.joyent.com/hc/en-us/articles/360000124928" }, { "name": "https://zerodayinitiative.com/advisories/ZDI-18-158", "refsource": "MISC", "url": "https://zerodayinitiative.com/advisories/ZDI-18-158" }, { "name": "https://www.oracle.com/security-alerts/cpuapr2020.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuapr2020.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2018-1165", "datePublished": "2018-02-21T14:00:00", "dateReserved": "2017-12-05T00:00:00", "dateUpdated": "2024-08-05T03:51:48.985Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }