All the vulnerabilites related to LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME - LAquis SCADA
cve-2018-17895
Vulnerability from cvelistv5
Published
2018-10-17 02:00
Modified
2024-09-17 02:52
Severity ?
Summary
LAquis SCADA Versions 4.1.0.3870 and prior has several out-of-bounds read vulnerabilities, which may allow remote code execution.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:01:14.672Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://laquisscada.com/instale1.php"
          },
          {
            "name": "105719",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105719"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LAquis SCADA",
          "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.0.3870 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior has several out-of-bounds read vulnerabilities, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "OUT-OF-BOUNDS READ CWE-125",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-25T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "name": "105719",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-16T00:00:00",
          "ID": "CVE-2018-17895",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LAquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.0.3870 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "LAquis SCADA Versions 4.1.0.3870 and prior has several out-of-bounds read vulnerabilities, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS READ CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://laquisscada.com/instale1.php",
              "refsource": "MISC",
              "url": "http://laquisscada.com/instale1.php"
            },
            {
              "name": "105719",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105719"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-17895",
    "datePublished": "2018-10-17T02:00:00Z",
    "dateReserved": "2018-10-02T00:00:00",
    "dateUpdated": "2024-09-17T02:52:22.745Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-6536
Vulnerability from cvelistv5
Published
2019-03-27 15:25
Modified
2024-08-04 20:23
Severity ?
Summary
Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.362Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-307/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LAquis SCADA",
          "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 4.3.1.71"
            }
          ]
        }
      ],
      "datePublic": "2019-03-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "Out-of-Bounds Write CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-02T15:06:09",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-307/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-6536",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LAquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 4.3.1.71"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Out-of-Bounds Write CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-307/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-307/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6536",
    "datePublished": "2019-03-27T15:25:23",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:21.362Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-9414
Vulnerability from cvelistv5
Published
2024-10-17 15:59
Modified
2024-10-17 17:52
Summary
Cross-site Scripting vulnerability in LCDS LAquis SCADA
References
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9414",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-17T17:01:13.734098Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-17T17:52:13.378Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LAquis SCADA",
          "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME",
          "versions": [
            {
              "status": "affected",
              "version": "4.7.1.511"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Mounir Aarab reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIn LAquis SCADA version 4.7.1.511, a cross-site scripting vulnerability could allow an attacker to inject arbitrary code into a web page. This could allow an attacker to steal cookies, redirect users, or perform unauthorized actions.\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "In LAquis SCADA version 4.7.1.511, a cross-site scripting vulnerability could allow an attacker to inject arbitrary code into a web page. This could allow an attacker to steal cookies, redirect users, or perform unauthorized actions."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-17T15:59:24.981Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-291-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eLCDS recommends users update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://laquisscada.com/\"\u003eversion 4.7.1.611 or newer\u003c/a\u003e\u0026nbsp;versions of LAquis SCADA.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "LCDS recommends users update to  version 4.7.1.611 or newer https://laquisscada.com/ \u00a0versions of LAquis SCADA."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Cross-site Scripting vulnerability in LCDS LAquis SCADA",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-9414",
    "datePublished": "2024-10-17T15:59:24.981Z",
    "dateReserved": "2024-10-01T17:19:35.637Z",
    "dateUpdated": "2024-10-17T17:52:13.378Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-17899
Vulnerability from cvelistv5
Published
2018-10-17 02:00
Modified
2024-09-17 00:45
Severity ?
Summary
LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:01:14.645Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://laquisscada.com/instale1.php"
          },
          {
            "name": "105719",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105719"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LAquis SCADA",
          "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.0.3870 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "PATH TRAVERSAL CWE-22",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-25T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "name": "105719",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-16T00:00:00",
          "ID": "CVE-2018-17899",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LAquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.0.3870 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "PATH TRAVERSAL CWE-22"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://laquisscada.com/instale1.php",
              "refsource": "MISC",
              "url": "http://laquisscada.com/instale1.php"
            },
            {
              "name": "105719",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105719"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-17899",
    "datePublished": "2018-10-17T02:00:00Z",
    "dateReserved": "2018-10-02T00:00:00",
    "dateUpdated": "2024-09-17T00:45:27.781Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-17901
Vulnerability from cvelistv5
Published
2018-10-17 02:00
Modified
2024-09-16 21:57
Severity ?
Summary
LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:01:14.595Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://laquisscada.com/instale1.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LAquis SCADA",
          "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.0.3870 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "OUT-OF-BOUNDS WRITE CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-17T01:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-16T00:00:00",
          "ID": "CVE-2018-17901",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LAquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.0.3870 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS WRITE CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://laquisscada.com/instale1.php",
              "refsource": "MISC",
              "url": "http://laquisscada.com/instale1.php"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-17901",
    "datePublished": "2018-10-17T02:00:00Z",
    "dateReserved": "2018-10-02T00:00:00",
    "dateUpdated": "2024-09-16T21:57:33.671Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-17893
Vulnerability from cvelistv5
Published
2018-10-17 02:00
Modified
2024-09-17 03:13
Severity ?
Summary
LAquis SCADA Versions 4.1.0.3870 and prior has an untrusted pointer dereference vulnerability, which may allow remote code execution.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:01:14.614Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://laquisscada.com/instale1.php"
          },
          {
            "name": "105719",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105719"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LAquis SCADA",
          "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.0.3870 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior has an untrusted pointer dereference vulnerability, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "UNTRUSTED POINTER DEREFERENCE CWE-822",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-25T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "name": "105719",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-16T00:00:00",
          "ID": "CVE-2018-17893",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LAquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.0.3870 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "LAquis SCADA Versions 4.1.0.3870 and prior has an untrusted pointer dereference vulnerability, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "UNTRUSTED POINTER DEREFERENCE CWE-822"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://laquisscada.com/instale1.php",
              "refsource": "MISC",
              "url": "http://laquisscada.com/instale1.php"
            },
            {
              "name": "105719",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105719"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-17893",
    "datePublished": "2018-10-17T02:00:00Z",
    "dateReserved": "2018-10-02T00:00:00",
    "dateUpdated": "2024-09-17T03:13:47.712Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-17911
Vulnerability from cvelistv5
Published
2018-10-17 02:00
Modified
2024-09-16 18:34
Severity ?
Summary
LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:01:14.679Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://laquisscada.com/instale1.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LAquis SCADA",
          "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.0.3870 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-10-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-17T01:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-16T00:00:00",
          "ID": "CVE-2018-17911",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LAquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.1.0.3870 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://laquisscada.com/instale1.php",
              "refsource": "MISC",
              "url": "http://laquisscada.com/instale1.php"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-17911",
    "datePublished": "2018-10-17T02:00:00Z",
    "dateReserved": "2018-10-02T00:00:00",
    "dateUpdated": "2024-09-16T18:34:43.642Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}