All the vulnerabilites related to LCDS - LCDS Laquis SCADA
cve-2018-18986
Vulnerability from cvelistv5
Published
2019-02-05 18:00
Modified
2024-09-17 00:17
Severity ?
EPSS score ?
Summary
LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01 | x_refsource_MISC | |
http://www.securityfocus.com/bid/106634 | vdb-entry, x_refsource_BID |
Impacted products
▼ | Vendor | Product |
---|---|---|
LCDS | LCDS Laquis SCADA |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:23:08.495Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01" }, { "name": "106634", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106634" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "LCDS Laquis SCADA", "vendor": "LCDS", "versions": [ { "status": "affected", "version": "All versions prior to version 4.1.0.4150" } ] } ], "datePublic": "2019-01-15T00:00:00", "descriptions": [ { "lang": "en", "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "OUT-OF-BOUNDS WRITE CWE-787", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-02-06T10:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01" }, { "name": "106634", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106634" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2019-01-15T00:00:00", "ID": "CVE-2018-18986", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "LCDS Laquis SCADA", "version": { "version_data": [ { "version_value": "All versions prior to version 4.1.0.4150" } ] } } ] }, "vendor_name": "LCDS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "OUT-OF-BOUNDS WRITE CWE-787" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01" }, { "name": "106634", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106634" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-18986", "datePublished": "2019-02-05T18:00:00Z", "dateReserved": "2018-11-06T00:00:00", "dateUpdated": "2024-09-17T00:17:11.349Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-19029
Vulnerability from cvelistv5
Published
2019-02-05 18:00
Modified
2024-09-16 22:25
Severity ?
EPSS score ?
Summary
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01 | x_refsource_MISC | |
http://www.securityfocus.com/bid/106634 | vdb-entry, x_refsource_BID |
Impacted products
▼ | Vendor | Product |
---|---|---|
LCDS | LCDS Laquis SCADA |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:23:08.951Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01" }, { "name": "106634", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106634" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "LCDS Laquis SCADA", "vendor": "LCDS", "versions": [ { "status": "affected", "version": "All versions prior to version 4.1.0.4150" } ] } ], "datePublic": "2019-01-15T00:00:00", "descriptions": [ { "lang": "en", "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-822", "description": "UNTRUSTED POINTER DEREFERENCE CWE-822", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-02-06T10:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01" }, { "name": "106634", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106634" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2019-01-15T00:00:00", "ID": "CVE-2018-19029", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "LCDS Laquis SCADA", "version": { "version_data": [ { "version_value": "All versions prior to version 4.1.0.4150" } ] } } ] }, "vendor_name": "LCDS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "UNTRUSTED POINTER DEREFERENCE CWE-822" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01" }, { "name": "106634", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106634" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-19029", "datePublished": "2019-02-05T18:00:00Z", "dateReserved": "2018-11-06T00:00:00", "dateUpdated": "2024-09-16T22:25:18.489Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-19002
Vulnerability from cvelistv5
Published
2019-02-05 18:00
Modified
2024-09-16 20:27
Severity ?
EPSS score ?
Summary
LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01 | x_refsource_MISC | |
http://www.securityfocus.com/bid/106634 | vdb-entry, x_refsource_BID |
Impacted products
▼ | Vendor | Product |
---|---|---|
LCDS | LCDS Laquis SCADA |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:23:08.797Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01" }, { "name": "106634", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106634" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "LCDS Laquis SCADA", "vendor": "LCDS", "versions": [ { "status": "affected", "version": "All versions prior to version 4.1.0.4150" } ] } ], "datePublic": "2019-01-15T00:00:00", "descriptions": [ { "lang": "en", "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-02-06T10:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01" }, { "name": "106634", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106634" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2019-01-15T00:00:00", "ID": "CVE-2018-19002", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "LCDS Laquis SCADA", "version": { "version_data": [ { "version_value": "All versions prior to version 4.1.0.4150" } ] } } ] }, "vendor_name": "LCDS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01" }, { "name": "106634", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106634" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-19002", "datePublished": "2019-02-05T18:00:00Z", "dateReserved": "2018-11-06T00:00:00", "dateUpdated": "2024-09-16T20:27:21.831Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }