All the vulnerabilites related to Mitsubishi Electric - MELSEC iQ-R Series Motion Module
cve-2020-14523
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2024-09-16 23:36
Severity ?
EPSS score ?
Summary
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03 | x_refsource_MISC | |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf | x_refsource_MISC | |
https://jvn.jp/vu/JVNVU90224831/ | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric | CW Configurator |
Version: unspecified < |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.640Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU90224831/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CW Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.010L", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "FR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.22Y", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "GX Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.595V", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "GX Works3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.063R", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MELSOFT iQ AppPortal", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.17T", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version2.70Y", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MI Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "product": "MR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.110Q", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MT Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 1.156N", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MX Component", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 4.20W", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "RT ToolBox3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 1.70Y", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MELSEC iQ-R Series Motion Module", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 10", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "datePublic": "2020-07-30T00:00:00", "descriptions": [ { "lang": "en", "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-18T23:17:23", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/vu/JVNVU90224831/" } ], "source": { "advisory": "ICSA-20-212-03", "discovery": "UNKNOWN" }, "title": "Mitsubishi Electric Factory Automation Products Path Traversal", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-07-30T16:50:00.000Z", "ID": "CVE-2020-14523", "STATE": "PUBLIC", "TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CW Configurator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.010L" } ] } }, { "product_name": "FR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.22Y" } ] } }, { "product_name": "GX Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.595V" } ] } }, { "product_name": "GX Works3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.063R" } ] } }, { "product_name": "MELSOFT iQ AppPortal", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.17T" } ] } }, { "product_name": "MELSOFT Navigator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version2.70Y" } ] } }, { "product_name": "MI Configurator", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.110Q" } ] } }, { "product_name": "MT Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Versions 1.156N" } ] } }, { "product_name": "MX Component", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 4.20W" } ] } }, { "product_name": "RT ToolBox3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Versions 1.70Y" } ] } }, { "product_name": "MELSEC iQ-R Series Motion Module", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Versions 10" } ] } } ] }, "vendor_name": "Mitsubishi Electric" } ] } }, "credit": [ { "lang": "eng", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "name": "https://jvn.jp/vu/JVNVU90224831/", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU90224831/" } ] }, "solution": [ { "lang": "en" } ], "source": { "advisory": "ICSA-20-212-03", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-14523", "datePublished": "2022-02-11T17:40:29.187685Z", "dateReserved": "2020-06-19T00:00:00", "dateUpdated": "2024-09-16T23:36:20.299Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }