All the vulnerabilites related to Schneider Electric - Modicon Controllers M241 / M251
cve-2024-6528
Vulnerability from cvelistv5
Published
2024-07-11 09:03
Modified
2024-08-01 21:41
Summary
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
Impacted products
Vendor Product Version
Schneider Electric Modicon Controllers M258 / LMC058 Version: All versions
Schneider Electric Modicon Controllers M262 Version: All Versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6528",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-29T20:04:30.600996Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-29T20:04:38.247Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:41:03.525Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-04.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Controllers M241 / M251",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Controllers M258 / LMC058",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Controllers M262",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nCWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a\npage containing the injected payload.\n\n"
            }
          ],
          "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim\u2019s browser run arbitrary JavaScript when they visit a\npage containing the injected payload."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-11T09:03:27.074Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-191-04.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-6528",
    "datePublished": "2024-07-11T09:03:27.074Z",
    "dateReserved": "2024-07-05T09:35:52.875Z",
    "dateUpdated": "2024-08-01T21:41:03.525Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-11737
Vulnerability from cvelistv5
Published
2024-12-11 09:36
Modified
2024-12-11 15:22
Summary
CWE-20: Improper Input Validation vulnerability exists that could lead to a denial of service and a loss of confidentiality, integrity of the controller when an unauthenticated crafted Modbus packet is sent to the device.
Impacted products
Vendor Product Version
Schneider Electric Modicon Controllers M258 / LMC058 Version: All versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11737",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-11T15:21:56.954464Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-11T15:22:05.910Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Controllers M241 / M251",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Modicon Controllers M258 / LMC058",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-20: Improper Input Validation vulnerability exists that could lead to a denial of service and a loss of\nconfidentiality, integrity of the controller when an unauthenticated crafted Modbus packet is sent to the device. \n\n\n\u003cbr\u003e"
            }
          ],
          "value": "CWE-20: Improper Input Validation vulnerability exists that could lead to a denial of service and a loss of\nconfidentiality, integrity of the controller when an unauthenticated crafted Modbus packet is sent to the device."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-11T09:36:29.282Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-345-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-345-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-11737",
    "datePublished": "2024-12-11T09:36:29.282Z",
    "dateReserved": "2024-11-26T07:11:06.935Z",
    "dateUpdated": "2024-12-11T15:22:05.910Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}