All the vulnerabilites related to Rockwell Automation - Pavilion8
cve-2023-29463
Vulnerability from cvelistv5
Published
2023-09-12 16:42
Modified
2024-08-02 14:07
Severity ?
EPSS score ?
Summary
Pavilion8 Security Misconfiguration Vulnerability
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Rockwell Automation | Pavilion8 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:46.424Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140590" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Pavilion8", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c5.20" } ] } ], "datePublic": "2023-09-12T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users\u2019 session data and or log users out of their session.\u003c/span\u003e\n\n" } ], "value": "\nThe JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users\u2019 session data and or log users out of their session.\n\n" } ], "impacts": [ { "capecId": "CAPEC-115", "descriptions": [ { "lang": "en", "value": "CAPEC-115 Authentication Bypass" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287 Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-09-12T16:42:14.868Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140590" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cdiv\u003eRisk Mitigation \u0026amp; User Action\u003c/div\u003e\u003cdiv\u003eCustomers using the affected software are encouraged to apply the risk mitigations, if possible. Additionally, we encourage customers to implement our suggested security best practices to minimize the risk of vulnerability.\u003cul\u003e\u003cli\u003eUpdate to v5.20\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012\"\u003eQA43240 - Recommended Security Guidelines from Rockwell Automation\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cstrong\u003eIf customers are unable to update to v5.20, please follow the instructions below to disable the vulnerability in v5.17.\u003c/strong\u003e\u003col\u003e\u003cli\u003eOpen the \u003ccode\u003eweb.xml\u003c/code\u003e\u0026nbsp;file in your Pavilion8\u00ae installation folder set during installation and go to \u003cem\u003eConsole\\container\\webapps\\ROOT\\WEB-INF\u003c/em\u003e, by default this would be under \u003ccode\u003eC:\\Pavilion\\Console\\container\\webapps\\ROOT\\WEB-INF\u003c/code\u003e.\u003c/li\u003e\u003cli\u003eSearch for the text \u003ccode\u003ejmx-console-action-handler\u003c/code\u003e\u0026nbsp;and delete the below lines from \u003ccode\u003eweb.xml\u003c/code\u003e\u0026nbsp;file:\u003cbr\u003e\u003cbr\u003e\u003ccode\u003e\u0026nbsp; \u0026lt;servlet\u0026gt;\u003cbr\u003e\u0026nbsp; \u0026nbsp; \u0026lt;servlet-name\u0026gt;jmx-console-action-handler\u0026lt;/servlet-name\u0026gt;\u003cbr\u003e\u0026nbsp; \u0026nbsp; \u0026lt;servlet-class\u0026gt;com.pav.jboss.jmx.HtmlAdaptorServlet\u0026lt;/servlet-class\u0026gt;\u003cbr\u003e\u0026nbsp; \u0026lt;/servlet\u0026gt;\u003cbr\u003e\u0026nbsp; \u0026lt;servlet-mapping\u0026gt;\u003cbr\u003e\u0026nbsp; \u0026nbsp; \u0026lt;servlet-name\u0026gt;jmx-console-action-handler\u0026lt;/servlet-name\u0026gt;\u003cbr\u003e\u0026nbsp; \u0026nbsp; \u0026lt;url-pattern\u0026gt;/jmx-console/HtmlAdaptor\u0026lt;/url-pattern\u0026gt;\u003cbr\u003e\u0026nbsp; \u0026lt;/servlet-mapping\u0026gt;\u003c/code\u003e\u003cbr\u003e\u0026nbsp;\u003c/li\u003e\u003cli\u003eSave the changes and close the file.\u003c/li\u003e\u003cli\u003eRestart \u003cstrong\u003ePavilion8\u00ae Console Service\u003c/strong\u003e.\u003c/li\u003e\u003cli\u003eLogout and log back into the console and navigate to the URL \u003ccode\u003ehttp:// \u0026lt;FQDN\u0026gt;/jmx-console\u003c/code\u003e\u0026nbsp;to confirm you are getting the error message \u003ccode\u003eHTTP Status 404 \u2013 Not Found\u003c/code\u003e.\u003c/li\u003e\u003c/ol\u003e\u003cblockquote\u003e\u003cp\u003e\u003cu\u003eNote\u003c/u\u003e: \u003ccode\u003e\u0026lt;FQDN\u0026gt;\u003c/code\u003e\u0026nbsp;is your fully qualified domain name used for the Console login.\u003c/p\u003e\u003c/blockquote\u003e\u003c/div\u003e\n\n\u003cbr\u003e" } ], "value": "\nRisk Mitigation \u0026 User Action\n\nCustomers using the affected software are encouraged to apply the risk mitigations, if possible. Additionally, we encourage customers to implement our suggested security best practices to minimize the risk of vulnerability. * Update to v5.20\n * QA43240 - Recommended Security Guidelines from Rockwell Automation https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012 \n\n\n\nIf customers are unable to update to v5.20, please follow the instructions below to disable the vulnerability in v5.17. * Open the web.xml\u00a0file in your Pavilion8\u00ae installation folder set during installation and go to Console\\container\\webapps\\ROOT\\WEB-INF, by default this would be under C:\\Pavilion\\Console\\container\\webapps\\ROOT\\WEB-INF.\n * Search for the text jmx-console-action-handler\u00a0and delete the below lines from web.xml\u00a0file:\n\n\u00a0 \u003cservlet\u003e\n\u00a0 \u00a0 \u003cservlet-name\u003ejmx-console-action-handler\u003c/servlet-name\u003e\n\u00a0 \u00a0 \u003cservlet-class\u003ecom.pav.jboss.jmx.HtmlAdaptorServlet\u003c/servlet-class\u003e\n\u00a0 \u003c/servlet\u003e\n\u00a0 \u003cservlet-mapping\u003e\n\u00a0 \u00a0 \u003cservlet-name\u003ejmx-console-action-handler\u003c/servlet-name\u003e\n\u00a0 \u00a0 \u003curl-pattern\u003e/jmx-console/HtmlAdaptor\u003c/url-pattern\u003e\n\u00a0 \u003c/servlet-mapping\u003e\n\u00a0\n * Save the changes and close the file.\n * Restart Pavilion8\u00ae Console Service.\n * Logout and log back into the console and navigate to the URL http:// \u003cFQDN\u003e/jmx-console\u00a0to confirm you are getting the error message HTTP Status 404 \u2013 Not Found.\nNote: \u003cFQDN\u003e\u00a0is your fully qualified domain name used for the Console login.\n\n\n\n\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "Pavilion8 Security Misconfiguration Vulnerability", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2023-29463", "datePublished": "2023-09-12T16:42:14.868Z", "dateReserved": "2023-04-06T18:42:59.008Z", "dateUpdated": "2024-08-02T14:07:46.424Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202309-0807
Vulnerability from variot
The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session. * Inappropriate authentication (CWE-287) - CVE-2023-29463If the vulnerability is exploited, it may be affected as follows
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202309-0807", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "pavilion8", "scope": "lt", "trust": 1.0, "vendor": "rockwellautomation", "version": "5.20" }, { "model": "pavilion8", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": null }, { "model": "pavilion8", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "v5.17.00 v5.17.01" }, { "model": "automation pavilion8", "scope": "lt", "trust": 0.6, "vendor": "rockwell", "version": "5.20" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-79689" }, { "db": "JVNDB", "id": "JVNDB-2023-003711" }, { "db": "NVD", "id": "CVE-2023-29463" } ] }, "cve": "CVE-2023-29463", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2023-79689", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "impactScore": 2.5, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "PSIRT@rockwellautomation.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2023-29463", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-29463", "trust": 1.8, "value": "MEDIUM" }, { "author": "PSIRT@rockwellautomation.com", "id": "CVE-2023-29463", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-79689", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-79689" }, { "db": "JVNDB", "id": "JVNDB-2023-003711" }, { "db": "NVD", "id": "CVE-2023-29463" }, { "db": "NVD", "id": "CVE-2023-29463" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "\nThe JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users\u2019 session data and or log users out of their session. * Inappropriate authentication (CWE-287) - CVE-2023-29463If the vulnerability is exploited, it may be affected as follows", "sources": [ { "db": "NVD", "id": "CVE-2023-29463" }, { "db": "JVNDB", "id": "JVNDB-2023-003711" }, { "db": "CNVD", "id": "CNVD-2023-79689" }, { "db": "VULMON", "id": "CVE-2023-29463" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-29463", "trust": 3.3 }, { "db": "JVN", "id": "JVNVU92147395", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-257-07", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-003711", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-79689", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-29463", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-79689" }, { "db": "VULMON", "id": "CVE-2023-29463" }, { "db": "JVNDB", "id": "JVNDB-2023-003711" }, { "db": "NVD", "id": "CVE-2023-29463" } ] }, "id": "VAR-202309-0807", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-79689" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-79689" } ] }, "last_update_date": "2024-05-17T23:03:15.491000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Pavilion8\u00a0Security\u00a0Misconfiguration\u00a0Vulnerability (Login required)", "trust": 0.8, "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140590" }, { "title": "Patch for Rockwell Automation Pavilion8 authorization issue vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/466231" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-79689" }, { "db": "JVNDB", "id": "JVNDB-2023-003711" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-287", "trust": 1.0 }, { "problemtype": "Inappropriate authentication (CWE-287) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-003711" }, { "db": "NVD", "id": "CVE-2023-29463" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-29463" }, { "trust": 1.1, "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140590" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu92147395/" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-257-07" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-79689" }, { "db": "VULMON", "id": "CVE-2023-29463" }, { "db": "JVNDB", "id": "JVNDB-2023-003711" }, { "db": "NVD", "id": "CVE-2023-29463" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-79689" }, { "db": "VULMON", "id": "CVE-2023-29463" }, { "db": "JVNDB", "id": "JVNDB-2023-003711" }, { "db": "NVD", "id": "CVE-2023-29463" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-24T00:00:00", "db": "CNVD", "id": "CNVD-2023-79689" }, { "date": "2023-09-12T00:00:00", "db": "VULMON", "id": "CVE-2023-29463" }, { "date": "2023-09-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-003711" }, { "date": "2023-09-12T17:15:09.147000", "db": "NVD", "id": "CVE-2023-29463" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-23T00:00:00", "db": "CNVD", "id": "CNVD-2023-79689" }, { "date": "2023-09-12T00:00:00", "db": "VULMON", "id": "CVE-2023-29463" }, { "date": "2024-05-15T08:32:00", "db": "JVNDB", "id": "JVNDB-2023-003711" }, { "date": "2023-09-15T19:14:44.543000", "db": "NVD", "id": "CVE-2023-29463" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Rockwell\u00a0Automation\u00a0 Made \u00a0Pavilion8\u00a0 Improper authentication vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-003711" } ], "trust": 0.8 } }