All the vulnerabilites related to Schneider Electric - PowerLogic PM5340
cve-2024-9409
Vulnerability from cvelistv5
Published
2024-11-13 04:29
Modified
2024-11-13 14:43
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS score ?
Summary
CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become
unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:schneider-electric:powerlogic_pm5320:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "powerlogic_pm5320", "vendor": "schneider-electric", "versions": [ { "lessThanOrEqual": "2.3.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:schneider-electric:powerlogic_pm5340:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "powerlogic_pm5340", "vendor": "schneider-electric", "versions": [ { "lessThanOrEqual": "2.3.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:schneider-electric:powerlogic_pm5341:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "powerlogic_pm5341", "vendor": "schneider-electric", "versions": [ { "lessThanOrEqual": "2.6.6", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-9409", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-13T14:40:24.630364Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-13T14:43:17.912Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerLogic PM5320", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2.3.8 and prior" } ] }, { "defaultStatus": "unaffected", "product": "PowerLogic PM5340", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2.3.8 and prior" } ] }, { "defaultStatus": "unaffected", "product": "PowerLogic PM5341", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Version 2.6.6 and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.\n\n\u003cbr\u003e" } ], "value": "CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-13T04:29:01.040Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2024-9409", "datePublished": "2024-11-13T04:29:01.040Z", "dateReserved": "2024-10-01T12:08:25.066Z", "dateUpdated": "2024-11-13T14:43:17.912Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }