All the vulnerabilites related to ABB - REX640 PCL3
cve-2022-1596
Vulnerability from cvelistv5
Published
2022-06-21 14:23
Modified
2024-09-16 23:11
Severity ?
EPSS score ?
Summary
ABB Relion REX640 Insufficient file access control
References
▼ | URL | Tags |
---|---|---|
https://search.abb.com/library/Download.aspx?DocumentID=2NGA001421 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
ABB | REX640 PCL1 | |
ABB | REX640 PCL2 | |
ABB | REX640 PCL3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:10:03.785Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001421" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "REX640 PCL1", "vendor": "ABB", "versions": [ { "lessThanOrEqual": "1.0.7", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "REX640 PCL2", "vendor": "ABB", "versions": [ { "lessThan": "1.1.4", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "REX640 PCL3", "vendor": "ABB", "versions": [ { "lessThan": "1.2.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "ABB thanks Paul Mader and Gianluca Raberger of VERBUND AG\u0027s OT Cyber Security Lab for helping to identify the vulnerabilities and protecting our customers." } ], "datePublic": "2022-06-21T00:00:00", "descriptions": [ { "lang": "en", "value": "Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732 Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-06-21T14:23:42", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001421" } ], "source": { "discovery": "UNKNOWN" }, "title": "ABB Relion REX640 Insufficient file access control", "workarounds": [ { "lang": "en", "value": "Although these workarounds will not correct the underlying vulnerability, they can help blocking known \nattack vectors. \n\u2022 Limit the HTTP(s) and FTP(S) to a local network by a firewall\n\u2022 Use a next generation (OSI layer 7) firewall for blocking the traffic to the userdb.xml file\n\u2022 Disable remote WHMI and FTP(S) and use local HMI only" } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@ch.abb.com", "DATE_PUBLIC": "2022-06-21T12:22:00.000Z", "ID": "CVE-2022-1596", "STATE": "PUBLIC", "TITLE": "ABB Relion REX640 Insufficient file access control" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "REX640 PCL1", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "1.0.7" } ] } }, { "product_name": "REX640 PCL2", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "1.1.4" } ] } }, { "product_name": "REX640 PCL3", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "1.2.1" } ] } } ] }, "vendor_name": "ABB" } ] } }, "credit": [ { "lang": "eng", "value": "ABB thanks Paul Mader and Gianluca Raberger of VERBUND AG\u0027s OT Cyber Security Lab for helping to identify the vulnerabilities and protecting our customers." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-732 Incorrect Permission Assignment for Critical Resource" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001421", "refsource": "MISC", "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001421" } ] }, "source": { "discovery": "UNKNOWN" }, "work_around": [ { "lang": "en", "value": "Although these workarounds will not correct the underlying vulnerability, they can help blocking known \nattack vectors. \n\u2022 Limit the HTTP(s) and FTP(S) to a local network by a firewall\n\u2022 Use a next generation (OSI layer 7) firewall for blocking the traffic to the userdb.xml file\n\u2022 Disable remote WHMI and FTP(S) and use local HMI only" } ] } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2022-1596", "datePublished": "2022-06-21T14:23:42.343945Z", "dateReserved": "2022-05-05T00:00:00", "dateUpdated": "2024-09-16T23:11:43.087Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-2876
Vulnerability from cvelistv5
Published
2023-06-13 03:52
Modified
2024-08-02 06:33
Severity ?
EPSS score ?
Summary
Session cookie exposure for client side script
References
Impacted products
▼ | Vendor | Product |
---|---|---|
ABB | REX640 PCL1 | |
ABB | REX640 PCL2 | |
ABB | REX640 PCL3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T06:33:06.232Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001423\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "modules": [ "firmware" ], "product": "REX640 PCL1", "vendor": "ABB", "versions": [ { "lessThan": "1.0.8", "status": "affected", "version": "1.0;0", "versionType": "firmware update" } ] }, { "defaultStatus": "unaffected", "modules": [ "Firmware" ], "product": "REX640 PCL2", "vendor": "ABB", "versions": [ { "lessThan": "1.1.4", "status": "affected", "version": "1.0;0", "versionType": "firwmare update" } ] }, { "defaultStatus": "unaffected", "modules": [ "firmware" ], "product": "REX640 PCL3", "vendor": "ABB", "versions": [ { "lessThan": "1.2.1", "status": "affected", "version": "1.0;0", "versionType": "firwmare update" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "ABB thanks Paul Mader and Gianluca Raberger of VERBUND AG\u0027s OT Cyber Security Lab for helping to identify the vulnerabilities and protecting our customers." } ], "datePublic": "2023-06-12T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Sensitive Cookie Without \u0027HttpOnly\u0027 Flag vulnerability in ABB REX640 PCL1 (firmware modules), ABB REX640 PCL2 (Firmware modules), ABB REX640 PCL3 (firmware modules) allows Cross-Site Scripting (XSS).\u003cp\u003eThis issue affects REX640 PCL1: from 1.0;0 before 1.0.8; REX640 PCL2: from 1.0;0 before 1.1.4; REX640 PCL3: from 1.0;0 before 1.2.1.\u003c/p\u003e" } ], "value": "Sensitive Cookie Without \u0027HttpOnly\u0027 Flag vulnerability in ABB REX640 PCL1 (firmware modules), ABB REX640 PCL2 (Firmware modules), ABB REX640 PCL3 (firmware modules) allows Cross-Site Scripting (XSS).This issue affects REX640 PCL1: from 1.0;0 before 1.0.8; REX640 PCL2: from 1.0;0 before 1.1.4; REX640 PCL3: from 1.0;0 before 1.2.1.\n\n" } ], "impacts": [ { "capecId": "CAPEC-63", "descriptions": [ { "lang": "en", "value": "CAPEC-63 Cross-Site Scripting (XSS)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 3.1, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1004", "description": "CWE-1004 Sensitive Cookie Without \u0027HttpOnly\u0027 Flag", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-13T03:52:12.002Z", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001423\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "source": { "discovery": "UNKNOWN" }, "title": "Session cookie exposure for client side script", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2023-2876", "datePublished": "2023-06-13T03:52:12.002Z", "dateReserved": "2023-05-24T17:41:29.260Z", "dateUpdated": "2024-08-02T06:33:06.232Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }