All the vulnerabilites related to Hitachi Energy - Relion 670/650 Series
cve-2021-35535
Vulnerability from cvelistv5
Published
2021-11-18 15:53
Modified
2024-09-16 17:42
Summary
Insufficient Security Control Vulnerability
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:40:47.142Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Relion 670 Series",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "affected",
              "version": "2.2.2 all revisions"
            },
            {
              "lessThan": "2.2.3.3",
              "status": "affected",
              "version": "2.2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Relion 670/650 Series",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "affected",
              "version": "2.2.0 all revisions"
            },
            {
              "status": "affected",
              "version": "2.2.4 all revisions"
            }
          ]
        },
        {
          "product": "Relion 670/650/SAM600-IO",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "affected",
              "version": "2.2.1 all revisions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Hitachi Energy thanks the following for working with us to help protect customers: U.S. Department of Energy CyTRICS researcher Riley Barello Myers."
        }
      ],
      "datePublic": "2021-11-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Insecure Default Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-18T15:53:12",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Refer to the cybersecurity advisories at https://www.hitachienergy.com/cybersecurity/alerts-and-notifications"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Insufficient Security Control Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@hitachienergy.com",
          "DATE_PUBLIC": "2021-11-04T11:00:00.000Z",
          "ID": "CVE-2021-35535",
          "STATE": "PUBLIC",
          "TITLE": "Insufficient Security Control Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Relion 670 Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "2.2.2",
                            "version_value": "2.2.2 all revisions"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "2.2.3",
                            "version_value": "2.2.3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Relion 670/650 Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "2.2.0",
                            "version_value": "2.2.0 all revisions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "2.2.4",
                            "version_value": "2.2.4 all revisions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Relion 670/650/SAM600-IO",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "2.2.1",
                            "version_value": "2.2.1 all revisions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hitachi Energy"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Hitachi Energy thanks the following for working with us to help protect customers: U.S. Department of Energy CyTRICS researcher Riley Barello Myers."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-1188 Insecure Default Initialization of Resource"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000061\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Refer to the cybersecurity advisories at https://www.hitachienergy.com/cybersecurity/alerts-and-notifications"
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2021-35535",
    "datePublished": "2021-11-18T15:53:12.711689Z",
    "dateReserved": "2021-06-28T00:00:00",
    "dateUpdated": "2024-09-16T17:42:37.566Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-35534
Vulnerability from cvelistv5
Published
2021-11-18 16:35
Modified
2024-09-16 18:45
Summary
Insufficient Security Control Vulnerability
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:40:47.237Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000058\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000059\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000060\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Relion 670 Series",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "affected",
              "version": "2.0 all revisions"
            },
            {
              "status": "affected",
              "version": "2.2.2 all revisions"
            },
            {
              "lessThan": "2.2.3.5",
              "status": "affected",
              "version": "2.2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Relion 670/650 Series",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "affected",
              "version": "2.2.0 all revisions"
            },
            {
              "status": "affected",
              "version": "2.2.4 all revisions"
            },
            {
              "status": "affected",
              "version": "2.1 all revisions"
            }
          ]
        },
        {
          "product": "Relion 670/650/SAM600-IO",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "affected",
              "version": "2.2.1 all revisions"
            },
            {
              "lessThan": "2.2.5.2",
              "status": "affected",
              "version": "2.2.5",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Relion 650",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "affected",
              "version": "1.1 all revisions"
            },
            {
              "status": "affected",
              "version": "1.2 all revisions"
            },
            {
              "status": "affected",
              "version": "1.0 all revisions"
            },
            {
              "lessThan": "1.3.0.8",
              "status": "affected",
              "version": "1.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GMS600",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "status": "affected",
              "version": "1.3.0"
            },
            {
              "status": "affected",
              "version": "1.3.1.0 1.3.0.1"
            },
            {
              "status": "affected",
              "version": "1.2.0"
            }
          ]
        },
        {
          "product": "PWC600",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "1.0.1.4",
              "status": "affected",
              "version": "1.0.1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "1.1.0.1",
              "status": "affected",
              "version": "1.1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Hitachi Energy thanks the following for working with us to help protect customers: U.S. Department of Energy CyTRICS researcher Robert Erbes."
        }
      ],
      "datePublic": "2021-11-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal database tables, could allow anybody with user credentials to bypass security controls that is enforced by the product. Consequently, exploitation may lead to unauthorized modifications on data/firmware, and/or to permanently disabling the product. This issue affects: Hitachi Energy Relion 670 Series 2.0 all revisions; 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.5. Hitachi Energy Relion 670/650 Series 2.1 all revisions. 2.2.0 all revisions; 2.2.4 all revisions; Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions; 2.2.5 versions prior to 2.2.5.2. Hitachi Energy Relion 650 1.0 all revisions. 1.1 all revisions; 1.2 all revisions; 1.3 versions prior to 1.3.0.8; Hitachi Energy GMS600 1.3.0; 1.3.0.1; 1.2.0. Hitachi Energy PWC600 1.0.1 version 1.0.1.4 and prior versions; 1.1.0 version 1.1.0.1 and prior versions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-274",
              "description": "CWE-274 Improper Handling of Insufficient Privileges",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-18T16:35:03",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000058\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000059\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000060\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Refer to the cybersecurity advisories at https://www.hitachienergy.com/cybersecurity/alerts-and-notifications"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Insufficient Security Control Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@hitachienergy.com",
          "DATE_PUBLIC": "2021-11-04T11:00:00.000Z",
          "ID": "CVE-2021-35534",
          "STATE": "PUBLIC",
          "TITLE": "Insufficient Security Control Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Relion 670 Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "2.0",
                            "version_value": "2.0 all revisions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "2.2.2",
                            "version_value": "2.2.2 all revisions"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "2.2.3",
                            "version_value": "2.2.3.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Relion 670/650 Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "2.2.0",
                            "version_value": "2.2.0 all revisions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "2.2.4",
                            "version_value": "2.2.4 all revisions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "2.1",
                            "version_value": "2.1 all revisions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Relion 670/650/SAM600-IO",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "2.2.1",
                            "version_value": "2.2.1 all revisions"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "2.2.5",
                            "version_value": "2.2.5.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Relion 650",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "1.1",
                            "version_value": "1.1 all revisions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "1.2",
                            "version_value": "1.2 all revisions"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "1.3",
                            "version_value": "1.3.0.8"
                          },
                          {
                            "version_name": "1.0",
                            "version_value": "1.0 all revisions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GMS600",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "1.3.0",
                            "version_value": "1.3.0"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "1.3.1.0",
                            "version_value": "1.3.0.1"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "1.2.0",
                            "version_value": "1.2.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PWC600",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "1.0.1",
                            "version_value": "1.0.1.4"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "1.1.0",
                            "version_value": "1.1.0.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hitachi Energy"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Hitachi Energy thanks the following for working with us to help protect customers: U.S. Department of Energy CyTRICS researcher Robert Erbes."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently restrict access to an internal database tables, could allow anybody with user credentials to bypass security controls that is enforced by the product. Consequently, exploitation may lead to unauthorized modifications on data/firmware, and/or to permanently disabling the product. This issue affects: Hitachi Energy Relion 670 Series 2.0 all revisions; 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.5. Hitachi Energy Relion 670/650 Series 2.1 all revisions. 2.2.0 all revisions; 2.2.4 all revisions; Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions; 2.2.5 versions prior to 2.2.5.2. Hitachi Energy Relion 650 1.0 all revisions. 1.1 all revisions; 1.2 all revisions; 1.3 versions prior to 1.3.0.8; Hitachi Energy GMS600 1.3.0; 1.3.0.1; 1.2.0. Hitachi Energy PWC600 1.0.1 version 1.0.1.4 and prior versions; 1.1.0 version 1.1.0.1 and prior versions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-274 Improper Handling of Insufficient Privileges"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000058\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000058\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000059\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000059\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000060\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000060\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Refer to the cybersecurity advisories at https://www.hitachienergy.com/cybersecurity/alerts-and-notifications"
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2021-35534",
    "datePublished": "2021-11-18T16:35:03.214009Z",
    "dateReserved": "2021-06-28T00:00:00",
    "dateUpdated": "2024-09-16T18:45:19.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}