All the vulnerabilites related to Siemens - SICAM PQ Analyzer
cve-2021-45460
Vulnerability from cvelistv5
Published
2022-01-11 11:27
Modified
2024-08-04 04:39
Severity ?
Summary
A vulnerability has been identified in SICAM PQ Analyzer (All versions < V3.18). A service is started by an unquoted registry entry. As there are spaces in this path, attackers with write privilege to those directories might be able to plant executables that will run in place of the legitimate process. Attackers might achieve persistence on the system ("backdoors") or cause a denial of service.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:39:21.093Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173318.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SICAM PQ Analyzer",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V3.18"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SICAM PQ Analyzer (All versions \u003c V3.18). A service is started by an unquoted registry entry. As there are spaces in this path, attackers with write privilege to those directories might be able to plant executables that will run in place of the legitimate process. Attackers might achieve persistence on the system (\"backdoors\") or cause a denial of service."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-428",
              "description": "CWE-428: Unquoted Search Path or Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-11T11:27:18",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173318.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-45460",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SICAM PQ Analyzer",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V3.18"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SICAM PQ Analyzer (All versions \u003c V3.18). A service is started by an unquoted registry entry. As there are spaces in this path, attackers with write privilege to those directories might be able to plant executables that will run in place of the legitimate process. Attackers might achieve persistence on the system (\"backdoors\") or cause a denial of service."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-428: Unquoted Search Path or Element"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-173318.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173318.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-45460",
    "datePublished": "2022-01-11T11:27:18",
    "dateReserved": "2021-12-22T00:00:00",
    "dateUpdated": "2024-08-04T04:39:21.093Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

var-201807-2193
Vulnerability from variot

A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue. plural Siemens The product contains an access control vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens IEC 61850 system configurator and so on are the products of German Siemens. Siemens IEC 61850 system configurator is a system configurator for smart substations; DIGSI is a unified configuration software for Siemens protection and measurement and control systems.

There are security holes in several Siemens products. An attacker can exploit this issue to bypass certain security restrictions and perform unauthorized actions; this may aid in launching further attacks

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201807-2193",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sicam pq analyzer",
        "scope": "lt",
        "trust": 1.8,
        "vendor": "siemens",
        "version": "3.11"
      },
      {
        "model": "digsi 4",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sicam scc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ec 61850 system configurator",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.80"
      },
      {
        "model": "digsi 5",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.80"
      },
      {
        "model": "sicam pas\\/pqs",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "8.11"
      },
      {
        "model": "digsi 4",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "digsi 5",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "iec 61850 system configurator",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "5.80"
      },
      {
        "model": "sicam pas/pqs",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "8.11"
      },
      {
        "model": "sicam scc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "iec system configurator",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "61850\u003cv5.80"
      },
      {
        "model": "digsi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "561850\u003cv7.80"
      },
      {
        "model": "digsi",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4\u003cv4.93"
      },
      {
        "model": "sicam pas/pqs",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.11"
      },
      {
        "model": "sicam pq analyzer",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v3.11"
      },
      {
        "model": "sicam scc hf3",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v9.02"
      },
      {
        "model": "sicam scc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "9.0"
      },
      {
        "model": "sicam pqs",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "8.10"
      },
      {
        "model": "sicam pq analyzer",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.10"
      },
      {
        "model": "sicam pas",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "8.10"
      },
      {
        "model": "sicam pas",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "8.08"
      },
      {
        "model": "sicam pas",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "8.07"
      },
      {
        "model": "sicam pas",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "8.00"
      },
      {
        "model": "sicam pas",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "6.0"
      },
      {
        "model": "iec system configurator",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "618504.0"
      },
      {
        "model": "digsi",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "57.0"
      },
      {
        "model": "digsi",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "44.92"
      },
      {
        "model": "sicam scc hf3",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "9.02"
      },
      {
        "model": "sicam pqs",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "8.11"
      },
      {
        "model": "sicam pq analyzer",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.11"
      },
      {
        "model": "sicam pas",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "8.11"
      },
      {
        "model": "iec system configurator",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "618505.80"
      },
      {
        "model": "digsi",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "57.80"
      },
      {
        "model": "digsi",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "44.93"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ec 61850 system configurator",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sicam pas pqs",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sicam pq analyzer",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sicam scc",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "digsi 4",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "digsi 5",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "db": "BID",
        "id": "105933"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-4858"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ec_61850_system_configurator_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.80",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ec_61850_system_configurator:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sicam_pq_analyzer_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.11",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sicam_pq_analyzer:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sicam_scc_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sicam_scc:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:digsi_4_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:digsi_4:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:digsi_5_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "7.80",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:digsi_5:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sicam_pas\\/pqs:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "8.11",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-4858"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The vendor reported this issue.",
    "sources": [
      {
        "db": "BID",
        "id": "105933"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2018-4858",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 9.3,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2018-4858",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2020-02201",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "VHN-134889",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2018-4858",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2018-4858",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-02201",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201807-480",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-134889",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "db": "VULHUB",
        "id": "VHN-134889"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-4858"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in IEC 61850 system configurator (All versions \u003c V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions \u003c V7.80), DIGSI 4 (All versions \u003c V4.93), SICAM PAS/PQS (All versions \u003c V8.11), SICAM PQ Analyzer (All versions \u003c V3.11), SICAM SCC (All versions \u003c V9.02 HF3). A service of the affected products listening on all of the host\u0027s network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service\u0027s client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue. plural Siemens The product contains an access control vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens IEC 61850 system configurator and so on are the products of German Siemens. Siemens IEC 61850 system configurator is a system configurator for smart substations; DIGSI is a unified configuration software for Siemens protection and measurement and control systems. \n\nThere are security holes in several Siemens products. \nAn attacker can exploit this issue to bypass certain security restrictions and perform unauthorized actions; this may aid in launching further attacks",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-4858"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "db": "BID",
        "id": "105933"
      },
      {
        "db": "IVD",
        "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e"
      },
      {
        "db": "VULHUB",
        "id": "VHN-134889"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-4858",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-317-01",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "105933",
        "trust": 2.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-159860",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-480",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "0CC7FCFD-B25F-456E-8B03-2034EC5B8A7E",
        "trust": 0.2
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-98851",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-134889",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "db": "VULHUB",
        "id": "VHN-134889"
      },
      {
        "db": "BID",
        "id": "105933"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-4858"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ]
  },
  "id": "VAR-201807-2193",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "db": "VULHUB",
        "id": "VHN-134889"
      }
    ],
    "trust": 1.583262806
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:43:38.897000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-159860",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-159860.pdf"
      },
      {
        "title": "Patch for Multiple Siemens Product Access Bypass Vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/197073"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=84011"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-284",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-134889"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-4858"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.8,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-01"
      },
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/105933"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-159860.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-4858"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-4858"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "db": "VULHUB",
        "id": "VHN-134889"
      },
      {
        "db": "BID",
        "id": "105933"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-4858"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "db": "VULHUB",
        "id": "VHN-134889"
      },
      {
        "db": "BID",
        "id": "105933"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-4858"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-01-14T00:00:00",
        "db": "IVD",
        "id": "0cc7fcfd-b25f-456e-8b03-2034ec5b8a7e"
      },
      {
        "date": "2020-01-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "date": "2018-07-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-134889"
      },
      {
        "date": "2018-11-15T00:00:00",
        "db": "BID",
        "id": "105933"
      },
      {
        "date": "2018-10-11T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "date": "2018-07-09T19:29:00.407000",
        "db": "NVD",
        "id": "CVE-2018-4858"
      },
      {
        "date": "2018-07-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-01-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-02201"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-134889"
      },
      {
        "date": "2018-11-15T00:00:00",
        "db": "BID",
        "id": "105933"
      },
      {
        "date": "2018-11-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      },
      {
        "date": "2023-10-16T13:52:15.963000",
        "db": "NVD",
        "id": "CVE-2018-4858"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Access control vulnerabilities in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008212"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "lack of information",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-480"
      }
    ],
    "trust": 0.6
  }
}

var-202201-0774
Vulnerability from variot

A vulnerability has been identified in SICAM PQ Analyzer (All versions < V3.18). A service is started by an unquoted registry entry. As there are spaces in this path, attackers with write privilege to those directories might be able to plant executables that will run in place of the legitimate process. Attackers might achieve persistence on the system ("backdoors") or cause a denial of service. SICAM PQ Analyzer contains an unquoted search path or element vulnerability.Information is tampered with and service operation is interrupted (DoS) It may be in a state. SICAM PQ Analyzer is a power quality system software that provides the option of evaluating archived PQ measurement data and fault records

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202201-0774",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sicam pq analyzer",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "3.18"
      },
      {
        "model": "sicam pq analyzer",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": "sicam pq analyzer  firmware  3.18"
      },
      {
        "model": "sicam pq analyzer",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45460"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sicam_pq_analyzer_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.18",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sicam_pq_analyzer:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-45460"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens has released an update for the SICAM PQ Analyzer and recommends users update to",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2021-45460",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.5,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 5.5,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2021-45460",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 3.6,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2022-02751",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "impactScore": 5.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.1,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2021-45460",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-45460",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-02751",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202201-869",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45460"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SICAM PQ Analyzer (All versions \u003c V3.18). A service is started by an unquoted registry entry. As there are spaces in this path, attackers with write privilege to those directories might be able to plant executables that will run in place of the legitimate process. Attackers might achieve persistence on the system (\"backdoors\") or cause a denial of service. SICAM PQ Analyzer contains an unquoted search path or element vulnerability.Information is tampered with and service operation is interrupted (DoS) It may be in a state. SICAM PQ Analyzer is a power quality system software that provides the option of evaluating archived PQ measurement data and fault records",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-45460"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-45460",
        "trust": 3.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-173318",
        "trust": 2.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-013-06",
        "trust": 1.4
      },
      {
        "db": "JVN",
        "id": "JVNVU98508242",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-869",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45460"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ]
  },
  "id": "VAR-202201-0774",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      }
    ],
    "trust": 1.24285713
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      }
    ]
  },
  "last_update_date": "2023-12-18T10:46:39.090000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-173318",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173318.pdf"
      },
      {
        "title": "Patch for Siemens SICAM PQ Analyzer Search Path Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/312991"
      },
      {
        "title": "Siemens Sicam Pq Analyzer Fixes for code issue vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=178728"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-428",
        "trust": 1.0
      },
      {
        "problemtype": "unquoted search path or element (CWE-428) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45460"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173318.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45460"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu98508242/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-06"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-013-06"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45460"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45460"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-01-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      },
      {
        "date": "2023-02-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "date": "2022-01-11T12:15:10.193000",
        "db": "NVD",
        "id": "CVE-2021-45460"
      },
      {
        "date": "2022-01-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-01-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-02751"
      },
      {
        "date": "2023-02-02T05:18:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      },
      {
        "date": "2022-01-18T20:29:54.297000",
        "db": "NVD",
        "id": "CVE-2021-45460"
      },
      {
        "date": "2022-02-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SICAM\u00a0PQ\u00a0Analyzer\u00a0 Unquoted Search Path or Element Vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-003005"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "code problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-869"
      }
    ],
    "trust": 0.6
  }
}