All the vulnerabilites related to Siemens - SIMATIC CP 442-1 RNA
cve-2019-19301
Vulnerability from cvelistv5
Published
2020-04-14 19:50
Modified
2024-08-05 02:16
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:16:46.705Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 442-1 RNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5.18" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 RNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5.18" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF180C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF182C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:U/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:01:51.207Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-19301", "datePublished": "2020-04-14T19:50:54", "dateReserved": "2019-11-26T00:00:00", "dateUpdated": "2024-08-05T02:16:46.705Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-27640
Vulnerability from cvelistv5
Published
2022-05-10 09:47
Modified
2024-08-03 05:32
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 442-1 RNA (All versions < V1.5.18), SIMATIC CP 443-1 RNA (All versions < V1.5.18). The affected devices improperly handles excessive ARP broadcast requests. This could allow an attacker to create a denial of service condition by performing ARP storming attacks, which can cause the device to reboot.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-480937.pdf | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Siemens | SIMATIC CP 442-1 RNA | |
Siemens | SIMATIC CP 443-1 RNA |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:32:59.808Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480937.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC CP 442-1 RNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5.18" } ] }, { "product": "SIMATIC CP 443-1 RNA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 442-1 RNA (All versions \u003c V1.5.18), SIMATIC CP 443-1 RNA (All versions \u003c V1.5.18). The affected devices improperly handles excessive ARP broadcast requests. This could allow an attacker to create a denial of service condition by performing ARP storming attacks, which can cause the device to reboot." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-20T13:11:32", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480937.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-27640", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC CP 442-1 RNA", "version": { "version_data": [ { "version_value": "All versions \u003c V1.5.18" } ] } }, { "product_name": "SIMATIC CP 443-1 RNA", "version": { "version_data": [ { "version_value": "All versions \u003c V1.5.18" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC CP 442-1 RNA (All versions \u003c V1.5.18), SIMATIC CP 443-1 RNA (All versions \u003c V1.5.18). The affected devices improperly handles excessive ARP broadcast requests. This could allow an attacker to create a denial of service condition by performing ARP storming attacks, which can cause the device to reboot." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-480937.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480937.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-27640", "datePublished": "2022-05-10T09:47:02", "dateReserved": "2022-03-22T00:00:00", "dateUpdated": "2024-08-03T05:32:59.808Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202205-0834
Vulnerability from variot
A vulnerability has been identified in SIMATIC CP 442-1 RNA (All versions < V1.5.18), SIMATIC CP 443-1 RNA (All versions < V1.5.18). The affected devices improperly handles excessive ARP broadcast requests. This could allow an attacker to create a denial of service condition by performing ARP storming attacks, which can cause the device to reboot. Siemens' simatic cp 442-1 rna firmware and simatic cp 443-1 rna Firmware has a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. Siemens SIMATIC CP 44x-1 RNA is a controller from Siemens (Siemens) company for communication processors connected to Ethernet
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202205-0834", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic cp 442-1 rna", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.5.18" }, { "model": "simatic cp 443-1 rna", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.5.18" }, { "model": "simatic cp 443-1 rna", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 442-1 rna", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp rna", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "443-1\u003cv1.5.18" }, { "model": "simatic cp rna", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "442-1\u003cv1.5.18" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-36386" }, { "db": "JVNDB", "id": "JVNDB-2022-010179" }, { "db": "NVD", "id": "CVE-2022-27640" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_442-1_rna_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.18", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_442-1_rna:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_rna_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.18", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_rna:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-27640" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202205-2739" } ], "trust": 0.6 }, "cve": "CVE-2022-27640", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "impactScore": 6.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 6.1, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-27640", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "CNVD-2022-36386", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-27640", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-27640", "trust": 1.8, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2022-36386", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202205-2739", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-36386" }, { "db": "JVNDB", "id": "JVNDB-2022-010179" }, { "db": "NVD", "id": "CVE-2022-27640" }, { "db": "CNNVD", "id": "CNNVD-202205-2739" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC CP 442-1 RNA (All versions \u003c V1.5.18), SIMATIC CP 443-1 RNA (All versions \u003c V1.5.18). The affected devices improperly handles excessive ARP broadcast requests. This could allow an attacker to create a denial of service condition by performing ARP storming attacks, which can cause the device to reboot. Siemens\u0027 simatic cp 442-1 rna firmware and simatic cp 443-1 rna Firmware has a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. Siemens SIMATIC CP 44x-1 RNA is a controller from Siemens (Siemens) company for communication processors connected to Ethernet", "sources": [ { "db": "NVD", "id": "CVE-2022-27640" }, { "db": "JVNDB", "id": "JVNDB-2022-010179" }, { "db": "CNVD", "id": "CNVD-2022-36386" }, { "db": "VULMON", "id": "CVE-2022-27640" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-27640", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-480937", "trust": 3.0 }, { "db": "ICS CERT", "id": "ICSA-22-132-11", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU92977068", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-010179", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-36386", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022051125", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202205-2739", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-27640", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-36386" }, { "db": "VULMON", "id": "CVE-2022-27640" }, { "db": "JVNDB", "id": "JVNDB-2022-010179" }, { "db": "NVD", "id": "CVE-2022-27640" }, { "db": "CNNVD", "id": "CNNVD-202205-2739" } ] }, "id": "VAR-202205-0834", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-36386" } ], "trust": 1.4333333000000001 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-36386" } ] }, "last_update_date": "2023-12-18T11:56:06.530000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SIMATIC CP 44x-1 RNA Denial of Service Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/332576" }, { "title": "Siemens SIMATIC Remediation of resource management error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=194577" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-36386" }, { "db": "CNNVD", "id": "CNNVD-202205-2739" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "Resource exhaustion (CWE-400) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-010179" }, { "db": "NVD", "id": "CVE-2022-27640" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480937.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu92977068/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-27640" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-11" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-480937.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-27640/" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-simatic-cp-442-1-cp-443-1-overload-via-arp-38296" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-132-11" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022051125" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-132-11" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-36386" }, { "db": "VULMON", "id": "CVE-2022-27640" }, { "db": "JVNDB", "id": "JVNDB-2022-010179" }, { "db": "NVD", "id": "CVE-2022-27640" }, { "db": "CNNVD", "id": "CNNVD-202205-2739" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-36386" }, { "db": "VULMON", "id": "CVE-2022-27640" }, { "db": "JVNDB", "id": "JVNDB-2022-010179" }, { "db": "NVD", "id": "CVE-2022-27640" }, { "db": "CNNVD", "id": "CNNVD-202205-2739" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-12T00:00:00", "db": "CNVD", "id": "CNVD-2022-36386" }, { "date": "2023-08-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-010179" }, { "date": "2022-05-20T13:15:15.077000", "db": "NVD", "id": "CVE-2022-27640" }, { "date": "2022-05-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202205-2739" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2022-36386" }, { "date": "2023-08-10T08:26:00", "db": "JVNDB", "id": "JVNDB-2022-010179" }, { "date": "2022-06-01T18:10:37.937000", "db": "NVD", "id": "CVE-2022-27640" }, { "date": "2022-06-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202205-2739" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202205-2739" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0simatic\u00a0cp\u00a0442-1\u00a0rna\u00a0 firmware and \u00a0simatic\u00a0cp\u00a0443-1\u00a0rna\u00a0 Firmware resource exhaustion vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-010179" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202205-2739" } ], "trust": 0.6 } }