All the vulnerabilites related to Siemens AG - SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8
cve-2018-11458
Vulnerability from cvelistv5
Published
2018-12-12 16:00
Modified
2024-08-05 08:10
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/106185 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf | x_refsource_CONFIRM |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T08:10:14.359Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "106185", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106185" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1" }, { "status": "affected", "version": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5" }, { "status": "affected", "version": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3" } ] } ], "datePublic": "2018-12-12T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-190", "description": "CWE-190: Integer Overflow or Wraparound", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-14T10:57:02", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "106185", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106185" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-11458", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8", "version": { "version_data": [ { "version_value": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1" }, { "version_value": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5" }, { "version_value": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-190: Integer Overflow or Wraparound" } ] } ] }, "references": { "reference_data": [ { "name": "106185", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106185" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-11458", "datePublished": "2018-12-12T16:00:00", "dateReserved": "2018-05-25T00:00:00", "dateUpdated": "2024-08-05T08:10:14.359Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-11457
Vulnerability from cvelistv5
Published
2018-12-12 16:00
Modified
2024-08-05 08:10
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/106185 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf | x_refsource_CONFIRM |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T08:10:14.429Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "106185", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106185" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1" }, { "status": "affected", "version": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5" }, { "status": "affected", "version": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3" } ] } ], "datePublic": "2018-12-12T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-14T10:57:02", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "106185", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106185" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-11457", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8", "version": { "version_data": [ { "version_value": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1" }, { "version_value": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5" }, { "version_value": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "106185", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106185" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-11457", "datePublished": "2018-12-12T16:00:00", "dateReserved": "2018-05-25T00:00:00", "dateUpdated": "2024-08-05T08:10:14.429Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-11464
Vulnerability from cvelistv5
Published
2018-12-12 16:00
Modified
2024-08-05 08:10
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/106185 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf | x_refsource_CONFIRM |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T08:10:14.565Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "106185", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106185" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1" }, { "status": "affected", "version": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5" }, { "status": "affected", "version": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3" } ] } ], "datePublic": "2018-12-12T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-248", "description": "CWE-248: Uncaught Exception", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-14T10:57:02", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "106185", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106185" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-11464", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8", "version": { "version_data": [ { "version_value": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1" }, { "version_value": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5" }, { "version_value": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-248: Uncaught Exception" } ] } ] }, "references": { "reference_data": [ { "name": "106185", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106185" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-11464", "datePublished": "2018-12-12T16:00:00", "dateReserved": "2018-05-25T00:00:00", "dateUpdated": "2024-08-05T08:10:14.565Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }