Search criteria

4 vulnerabilities found for SVMPC2 by Daikin

CVE-2022-38355 (GCVE-0-2022-38355)

Vulnerability from cvelistv5 – Published: 2022-12-13 21:12 – Updated: 2025-04-16 16:04
VLAI?
Summary
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to attackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Vendor Product Version
Daikin SVMPC1 Affected: 0 , ≤ 2.1.22 (custom)
Create a notification for this product.
    Daikin SVMPC2 Affected: 0 , ≤ 1.2.3 (custom)
Create a notification for this product.
Credits
Chizuru Toyama from TXOne Networks reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.383Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38355",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:53:21.791214Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:04:52.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SVMPC1 ",
          "vendor": "Daikin",
          "versions": [
            {
              "lessThanOrEqual": "2.1.22",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SVMPC2",
          "vendor": "Daikin",
          "versions": [
            {
              "lessThanOrEqual": "1.2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chizuru Toyama from TXOne Networks reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eattackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.\u003c/span\u003e\n\n"
            }
          ],
          "value": "Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to \n\nattackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T21:12:06.551Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nDaikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n\u003cbr\u003e"
            }
          ],
          "value": "Daikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n\n"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-38355",
    "datePublished": "2022-12-13T21:12:06.551Z",
    "dateReserved": "2022-09-29T14:08:03.143Z",
    "dateUpdated": "2025-04-16T16:04:52.712Z",
    "requesterUserId": "bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-41653 (GCVE-0-2022-41653)

Vulnerability from cvelistv5 – Published: 2022-12-13 21:08 – Updated: 2025-04-16 16:05
VLAI?
Summary
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system.
CWE
  • CWE-259 - Use of Hard-Coded Password
Assigner
Impacted products
Vendor Product Version
Daikin SVMPC1 Affected: 0 , ≤ 2.1.22 (custom)
Create a notification for this product.
    Daikin SVMPC2 Affected: 0 , ≤ 1.2.3 (custom)
Create a notification for this product.
Credits
Chizuru Toyama from TXOne Networks reported these vulnerabilities to CISA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:49:43.421Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-41653",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:52:34.591797Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:05:02.144Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SVMPC1 ",
          "vendor": "Daikin",
          "versions": [
            {
              "lessThanOrEqual": "2.1.22",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SVMPC2",
          "vendor": "Daikin",
          "versions": [
            {
              "lessThanOrEqual": "1.2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chizuru Toyama from TXOne Networks reported these vulnerabilities to CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system."
            }
          ],
          "value": "Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259 Use of Hard-Coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T21:08:36.871Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nDaikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n\u003cbr\u003e"
            }
          ],
          "value": "Daikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-41653",
    "datePublished": "2022-12-13T21:08:36.871Z",
    "dateReserved": "2022-09-29T14:08:03.135Z",
    "dateUpdated": "2025-04-16T16:05:02.144Z",
    "requesterUserId": "bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38355 (GCVE-0-2022-38355)

Vulnerability from nvd – Published: 2022-12-13 21:12 – Updated: 2025-04-16 16:04
VLAI?
Summary
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to attackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Vendor Product Version
Daikin SVMPC1 Affected: 0 , ≤ 2.1.22 (custom)
Create a notification for this product.
    Daikin SVMPC2 Affected: 0 , ≤ 1.2.3 (custom)
Create a notification for this product.
Credits
Chizuru Toyama from TXOne Networks reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.383Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38355",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:53:21.791214Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:04:52.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SVMPC1 ",
          "vendor": "Daikin",
          "versions": [
            {
              "lessThanOrEqual": "2.1.22",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SVMPC2",
          "vendor": "Daikin",
          "versions": [
            {
              "lessThanOrEqual": "1.2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chizuru Toyama from TXOne Networks reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eattackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.\u003c/span\u003e\n\n"
            }
          ],
          "value": "Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to \n\nattackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T21:12:06.551Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nDaikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n\u003cbr\u003e"
            }
          ],
          "value": "Daikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n\n"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-38355",
    "datePublished": "2022-12-13T21:12:06.551Z",
    "dateReserved": "2022-09-29T14:08:03.143Z",
    "dateUpdated": "2025-04-16T16:04:52.712Z",
    "requesterUserId": "bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-41653 (GCVE-0-2022-41653)

Vulnerability from nvd – Published: 2022-12-13 21:08 – Updated: 2025-04-16 16:05
VLAI?
Summary
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system.
CWE
  • CWE-259 - Use of Hard-Coded Password
Assigner
Impacted products
Vendor Product Version
Daikin SVMPC1 Affected: 0 , ≤ 2.1.22 (custom)
Create a notification for this product.
    Daikin SVMPC2 Affected: 0 , ≤ 1.2.3 (custom)
Create a notification for this product.
Credits
Chizuru Toyama from TXOne Networks reported these vulnerabilities to CISA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:49:43.421Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-41653",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:52:34.591797Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:05:02.144Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SVMPC1 ",
          "vendor": "Daikin",
          "versions": [
            {
              "lessThanOrEqual": "2.1.22",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SVMPC2",
          "vendor": "Daikin",
          "versions": [
            {
              "lessThanOrEqual": "1.2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Chizuru Toyama from TXOne Networks reported these vulnerabilities to CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system."
            }
          ],
          "value": "Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259 Use of Hard-Coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T21:08:36.871Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-284-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nDaikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n\u003cbr\u003e"
            }
          ],
          "value": "Daikin Holdings Singapore Pte Ltd. has released an update that will \nautomatically install if the SVM controller is enabled. No user \noperation is required. \n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-41653",
    "datePublished": "2022-12-13T21:08:36.871Z",
    "dateReserved": "2022-09-29T14:08:03.135Z",
    "dateUpdated": "2025-04-16T16:05:02.144Z",
    "requesterUserId": "bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}