All the vulnerabilites related to Kaspersky Lab - UltraVNC
cve-2019-8264
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 19:51
Severity ?
EPSS score ?
Summary
UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-011-ultravnc-access-of-memory-location-after-end-of-buffer/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.529Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-011-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-28T11:55:37", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-011-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8264", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-011-ultravnc-access-of-memory-location-after-end-of-buffer/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-011-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8264", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T19:51:49.467Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8277
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-08-04 21:17
Severity ?
EPSS score ?
Summary
UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/ | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.165Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "revision 1211" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-665", "description": "multiple memory leaks (CWE-665)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-28T12:26:17", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "ID": "CVE-2019-8277", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "revision 1211" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1211 contains multiple memory leaks (CWE-665) in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "multiple memory leaks (CWE-665)" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/", "refsource": "CONFIRM", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-024-ultravnc-improper-initialization/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8277", "datePublished": "2019-03-09T00:00:00", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-08-04T21:17:30.165Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8267
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 16:48
Severity ?
EPSS score ?
Summary
UltraVNC revision 1207 has out-of-bounds read vulnerability in VNC client code inside TextChat module, which results in a denial of service (DoS) condition. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1208.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-014-ultravnc-out-of-bounds-read/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:31.270Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-014-ultravnc-out-of-bounds-read/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1207 has out-of-bounds read vulnerability in VNC client code inside TextChat module, which results in a denial of service (DoS) condition. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1208." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:35:13", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-014-ultravnc-out-of-bounds-read/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8267", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1207 has out-of-bounds read vulnerability in VNC client code inside TextChat module, which results in a denial of service (DoS) condition. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1208." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-125: Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-014-ultravnc-out-of-bounds-read/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-014-ultravnc-out-of-bounds-read/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8267", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T16:48:26.336Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8269
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-17 00:30
Severity ?
EPSS score ?
Summary
UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.516Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:52:57", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8269", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121: Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8269", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-17T00:30:43.266Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8280
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-17 01:40
Severity ?
EPSS score ?
Summary
UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result code execution. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.735Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result code execution. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-28T12:18:29", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8280", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result code execution. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8280", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-17T01:40:44.392Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8266
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 23:05
Severity ?
EPSS score ?
Summary
UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.554Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:30:20", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8266", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8266", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T23:05:39.052Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8273
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 23:16
Severity ?
EPSS score ?
Summary
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:31.298Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:54:47", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8273", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-020-ultravnc-heap-based-buffer-overflow/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8273", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T23:16:03.189Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8268
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-17 01:16
Severity ?
EPSS score ?
Summary
UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.455Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-193", "description": "CWE-193: Off-by-one Error", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:52:16", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8268", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-193: Off-by-one Error" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-015-ultravnc-off-by-one-error/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8268", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-17T01:16:16.319Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8274
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 19:35
Severity ?
EPSS score ?
Summary
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.639Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:55:11", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8274", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-021-ultravnc-heap-based-buffer-overflow/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8274", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T19:35:36.652Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8276
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 18:33
Severity ?
EPSS score ?
Summary
UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.806Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:55:54", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8276", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121: Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8276", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T18:33:31.486Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8272
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 16:43
Severity ?
EPSS score ?
Summary
UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.483Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-193", "description": "CWE-193: Off-by-one Error", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:54:20", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8272", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-193: Off-by-one Error" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-019-ultravnc-off-by-one-error/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8272", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T16:43:07.206Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8263
Vulnerability from cvelistv5
Published
2019-03-05 15:00
Modified
2024-09-16 23:56
Severity ?
EPSS score ?
Summary
UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.560Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-28T11:53:57", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8263", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121: Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-009-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-010-ultravnc-stack-based-buffer-overflow/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8263", "datePublished": "2019-03-05T15:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T23:56:07.697Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8265
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 17:07
Severity ?
EPSS score ?
Summary
UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.842Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-28T11:57:30", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8265", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8265", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T17:07:55.620Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8271
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 23:26
Severity ?
EPSS score ?
Summary
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:31.251Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:53:56", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8271", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-122: Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-018-ultravnc-heap-based-buffer-overflow/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8271", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T23:26:16.493Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8270
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-16 16:34
Severity ?
EPSS score ?
Summary
UltraVNC revision 1210 has out-of-bounds read vulnerability in VNC client code inside Ultra decoder, which results in a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1211.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-017-ultravnc-out-of-bounds-read/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:31.273Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-017-ultravnc-out-of-bounds-read/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1210 has out-of-bounds read vulnerability in VNC client code inside Ultra decoder, which results in a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1211." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-12T20:53:21", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-017-ultravnc-out-of-bounds-read/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8270", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1210 has out-of-bounds read vulnerability in VNC client code inside Ultra decoder, which results in a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1211." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-125: Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-017-ultravnc-out-of-bounds-read/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-017-ultravnc-out-of-bounds-read/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8270", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-16T16:34:02.833Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-8275
Vulnerability from cvelistv5
Published
2019-03-09 00:00
Modified
2024-09-17 03:12
Severity ?
EPSS score ?
Summary
UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/ | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
▼ | Vendor | Product |
---|---|---|
Kaspersky Lab | UltraVNC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T21:17:30.848Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UltraVNC", "vendor": "Kaspersky Lab", "versions": [ { "status": "affected", "version": "1.2.2.3" } ] } ], "datePublic": "2019-03-01T00:00:00", "descriptions": [ { "lang": "en", "value": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-170", "description": "CWE-170: Improper Null Termination", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-28T12:15:25", "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "shortName": "Kaspersky" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnerability@kaspersky.com", "DATE_PUBLIC": "2019-03-01T00:00:00", "ID": "CVE-2019-8275", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UltraVNC", "version": { "version_data": [ { "version_value": "1.2.2.3" } ] } } ] }, "vendor_name": "Kaspersky Lab" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-170: Improper Null Termination" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/", "refsource": "MISC", "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-022-ultravnc-improper-null-termination/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988", "assignerShortName": "Kaspersky", "cveId": "CVE-2019-8275", "datePublished": "2019-03-09T00:00:00Z", "dateReserved": "2019-02-12T00:00:00", "dateUpdated": "2024-09-17T03:12:37.776Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }