All the vulnerabilites related to Hitachi Energy - eSOMS
cve-2023-5516
Vulnerability from cvelistv5
Published
2023-11-01 02:54
Modified
2024-08-02 07:59
Summary
Poorly constructed webap requests and URI components with special characters trigger unhandled errors and exceptions, disclosing information about the underlying technology and other sensitive information details. The website unintentionally reveals sensitive information including technical details like version Info, endpoints, backend server, Internal IP. etc., which can potentially expose additional attack surface containing other interesting vulnerabilities.
Impacted products
Hitachi EnergyeSOMS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:59:44.747Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000175\u0026languageCode=en\u0026Preview=true"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "eSOMS",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "6.3.13",
              "status": "affected",
              "version": "6.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nPoorly constructed webap requests and URI components with special characters trigger unhandled errors and exceptions, disclosing\ninformation about the underlying technology and other sensitive information details. The website unintentionally reveals sensitive information including technical details like version Info, endpoints,\nbackend server, Internal IP. etc., which can potentially expose additional attack surface containing other interesting vulnerabilities. \n\n"
            }
          ],
          "value": "\nPoorly constructed webap requests and URI components with special characters trigger unhandled errors and exceptions, disclosing\ninformation about the underlying technology and other sensitive information details. The website unintentionally reveals sensitive information including technical details like version Info, endpoints,\nbackend server, Internal IP. etc., which can potentially expose additional attack surface containing other interesting vulnerabilities. \n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-410",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-410 Information Elicitation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-01T02:54:21.225Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000175\u0026languageCode=en\u0026Preview=true"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2023-5516",
    "datePublished": "2023-11-01T02:54:21.225Z",
    "dateReserved": "2023-10-11T01:30:14.840Z",
    "dateUpdated": "2024-08-02T07:59:44.747Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-5515
Vulnerability from cvelistv5
Published
2023-11-01 02:49
Modified
2024-08-02 07:59
Summary
The responses for web queries with certain parameters disclose internal path of resources. This information can be used to learn internal structure of the application and to further plot attacks against web servers and deployed web applications.
Impacted products
Hitachi EnergyeSOMS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:59:44.854Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000175\u0026languageCode=en\u0026Preview=true"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "eSOMS",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "6.3.13",
              "status": "affected",
              "version": "6.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nThe responses for web queries with certain parameters disclose internal path of resources. This information can be used to learn internal structure of the application and to further plot attacks against\nweb servers and deployed web applications.\n\n"
            }
          ],
          "value": "\nThe responses for web queries with certain parameters disclose internal path of resources. This information can be used to learn internal structure of the application and to further plot attacks against\nweb servers and deployed web applications.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-410",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-410 Information Elicitation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-01T02:49:08.085Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000175\u0026languageCode=en\u0026Preview=true"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2023-5515",
    "datePublished": "2023-11-01T02:49:08.085Z",
    "dateReserved": "2023-10-11T01:30:12.236Z",
    "dateUpdated": "2024-08-02T07:59:44.854Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-5514
Vulnerability from cvelistv5
Published
2023-11-01 02:40
Modified
2024-08-02 07:59
Summary
The response messages received from the eSOMS report generation using certain parameter queries with full file path can be abused for enumerating the local file system structure.
Impacted products
Hitachi EnergyeSOMS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:59:44.760Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000175\u0026languageCode=en\u0026Preview=true"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "eSOMS",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "6.3.13",
              "status": "affected",
              "version": "6.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nThe response messages received from the eSOMS report generation using certain parameter queries with full file path can be\nabused for enumerating the local file system structure.\n\n"
            }
          ],
          "value": "\nThe response messages received from the eSOMS report generation using certain parameter queries with full file path can be\nabused for enumerating the local file system structure.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-410",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-410 Information Elicitation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-209",
              "description": "CWE-209 Generation of Error Message Containing Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-01T02:40:53.285Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000175\u0026languageCode=en\u0026Preview=true"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2023-5514",
    "datePublished": "2023-11-01T02:40:53.285Z",
    "dateReserved": "2023-10-11T01:30:06.720Z",
    "dateUpdated": "2024-08-02T07:59:44.760Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}