All the vulnerabilites related to siemens - simatic_hmi_basic_panels_2nd_generation
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_hmi_basic_panels_1st_generation:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF9AA1D8-BDF6-40EC-8D04-49C5EAB39431", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_basic_panels_2nd_generation:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E561873-49B4-4D85-8D40-9D33CEE7E7CE", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C98A381-02D5-460E-8849-63F4576BC52C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp700f_mobile_arctic_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BAC6E895-5577-4047-B7CC-95398563984D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp700f_mobile_arctic:-:*:*:*:*:*:*:*", "matchCriteriaId": "4631C615-B2A4-40C3-9D1A-A1AD3C64EC51", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08693615-7A47-4062-A73D-7CDE359826F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels_2nd_generation:-:*:*:*:*:*:*:*", "matchCriteriaId": "59D5490F-EACA-467F-89ED-988A45393EAC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Basic Panels 1st Generation (incluyendo las variantes SIPLUS) (Todas las versiones), SIMATIC HMI Basic Panels 2nd Generation (incluyendo las variantes SIPLUS) (Todas las versiones), SIMATIC HMI Comfort Panels (incluyendo las variantes SIPLUS) (Todas las versiones), SIMATIC HMI KTP700F Mobile Arctic (Todas las versiones), SIMATIC HMI Mobile Panels 2nd Generation (Todas las versiones), SIMATIC WinCC Runtime Advanced (Todas las versiones). Una comunicaci\u00f3n no cifrada entre el software de configuraci\u00f3n y el dispositivo respectivo podr\u00eda permitir a un atacante capturar la comunicaci\u00f3n potencial de texto plano y tener acceso a informaci\u00f3n confidencial" } ], "id": "CVE-2020-7592", "lastModified": "2024-11-21T05:37:26.090", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:19.073", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-319" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-319" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-09-09 19:15
Modified
2024-11-21 05:06
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04B80487-9B16-451E-914C-52D69D7E68C2", "versionEndIncluding": "14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C98A381-02D5-460E-8849-63F4576BC52C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA6D06D6-AA28-47C7-8944-A7500A330311", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "55E03180-BE77-4A22-A6C1-FE90B9760570", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_united_comfort_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DC20A46A-6B84-48E3-8E53-715F13BDFD4B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_united_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "2B1E4ACE-F6FE-4706-9720-89C3773AFDC4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions \u003c V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c= V16), SIMATIC HMI Mobile Panels (All versions \u003c= V16), SIMATIC HMI Unified Comfort Panels (All versions \u003c= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (Todas las versiones anteriores V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (Todas las versiones anteriores o iguales a la versi\u00f3nV16), SIMATIC HMI Mobile Panels (Todas las versiones anteriores o iguales a la versi\u00f3nV16), SIMATIC HMI Unified Comfort Panels (Todas las versiones anteriores o iguales a la versi\u00f3nV16). Los dispositivos afectados bloquean de forma insuficiente los intentos de autenticaci\u00f3n excesivos. Esto podr\u00eda permitir a un atacante remoto detectar las contrase\u00f1as de los usuarios y obtener acceso al Servidor Sm@rt mediante un ataque de fuerza bruta" } ], "id": "CVE-2020-15786", "lastModified": "2024-11-21T05:06:10.660", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-09-09T19:15:19.787", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-307" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-307" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-03-25 15:15
Modified
2024-11-21 06:21
Severity ?
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*", "matchCriteriaId": "B213E696-A6D9-45E7-B4E4-E4CFE54ECEB8", "versionEndExcluding": "1.1.1k", "versionStartIncluding": "1.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252", "vulnerable": true }, { "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*", "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:-:*:*:*:*:*:*", "matchCriteriaId": "73D9C08B-8F5B-40C4-A5BD-B00D2E4C012D", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p1:*:*:*:*:*:*", "matchCriteriaId": "62A178A3-6A52-4981-9A27-FB07AD8AF778", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p2:*:*:*:*:*:*", "matchCriteriaId": "54A487B1-E5CE-4C76-87E8-518D24C5D86D", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*", "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*", "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:e-series_performance_analyzer:-:*:*:*:*:*:*:*", "matchCriteriaId": "24B8DB06-590A-4008-B0AB-FCD1401C77C6", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*", "matchCriteriaId": "F1BE6C1F-2565-4E97-92AA-16563E5660A5", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*", "matchCriteriaId": "5735E553-9731-4AAC-BCFF-989377F817B3", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*", "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*", "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:snapcenter:-:*:*:*:*:*:*:*", "matchCriteriaId": "BDFB1169-41A0-4A86-8E4F-FDA9730B1E94", "vulnerable": true }, { "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*", "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:tenable:log_correlation_engine:*:*:*:*:*:*:*:*", "matchCriteriaId": "4ACF85D6-6B45-43DA-9C01-F0208186F014", "versionEndExcluding": "6.0.9", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*", "matchCriteriaId": "0AC12300-9051-4C70-9941-9FE5E64B4B30", "versionEndIncluding": "8.13.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.0:*:*:*:*:*:*:*", "matchCriteriaId": "657682A0-54D5-4DC6-A98E-8BAF685926C4", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.1:*:*:*:*:*:*:*", "matchCriteriaId": "8FC5C76C-3474-4B26-8CF0-2DFAFA3D5458", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.0:*:*:*:*:*:*:*", "matchCriteriaId": "8661D361-71B5-4C41-A818-C89EC551D900", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.1:*:*:*:*:*:*:*", "matchCriteriaId": "253603DC-2D92-442A-B3A8-A63E14D8A070", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.13.0:*:*:*:*:*:*:*", "matchCriteriaId": "8E112CFF-31F9-4D87-9A1B-AE0FCF69615E", "vulnerable": true }, { "criteria": "cpe:2.3:a:tenable:tenable.sc:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC1721B5-9FCD-47C3-8338-E02932CF2C05", "versionEndIncluding": "5.17.0", "versionStartIncluding": "5.13.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*", "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mcafee:web_gateway:8.2.19:*:*:*:*:*:*:*", "matchCriteriaId": "DEA7F1FD-9FAB-4654-98B0-4588EEC8B69A", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway:9.2.10:*:*:*:*:*:*:*", "matchCriteriaId": "868B2C4B-CE6B-41DA-A373-7D4FA51EFE9F", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway:10.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "550F47A2-3393-481E-BC40-CE606BFA8776", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:8.2.19:*:*:*:*:*:*:*", "matchCriteriaId": "43392D27-6C07-41C7-A17F-10C433338CE9", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:9.2.10:*:*:*:*:*:*:*", "matchCriteriaId": "8FBF6C4C-195F-49A7-861D-52677D9BE58D", "vulnerable": true }, { "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:10.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "90732D53-E802-4E1B-B6C8-B1FDCE7905A4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r80.40:*:*:*:*:*:*:*", "matchCriteriaId": "A98B128A-C58E-48EC-B691-AF73126A0822", "vulnerable": true }, { "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r81:*:*:*:*:*:*:*", "matchCriteriaId": "345B990F-C1C4-440B-804E-0A2882FE7C01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:checkpoint:quantum_security_management:-:*:*:*:*:*:*:*", "matchCriteriaId": "08601413-25E2-4977-B67A-C11A9D788EA8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r80.40:*:*:*:*:*:*:*", "matchCriteriaId": "EFC067CC-EB90-43F5-9674-089D5C611573", "vulnerable": true }, { "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r81:*:*:*:*:*:*:*", "matchCriteriaId": "80B223A7-1039-445D-ABE1-5E481004D956", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:checkpoint:multi-domain_management:-:*:*:*:*:*:*:*", "matchCriteriaId": "1584E1B4-412C-40E2-BF07-4E464692F2AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r80.40:*:*:*:*:*:*:*", "matchCriteriaId": "A0002A29-8B42-445D-9EC4-58BC93194241", "vulnerable": true }, { "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r81:*:*:*:*:*:*:*", "matchCriteriaId": "3B0EDB21-9305-4601-AB96-A77BD00F311D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:checkpoint:quantum_security_gateway:-:*:*:*:*:*:*:*", "matchCriteriaId": "9016DDF6-285C-4E64-88D0-29ECCEF048F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:oracle:communications_communications_policy_management:12.6.0.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "570DB369-A31B-4108-A7FD-09F674129603", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:enterprise_manager_for_storage_management:13.4.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "61516569-C48F-4362-B334-8CA10EDB0EC2", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:essbase:21.2:*:*:*:*:*:*:*", "matchCriteriaId": "394A16F2-CCD4-44E5-BF6B-E0C782A9FA38", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:graalvm:19.3.5:*:*:*:enterprise:*:*:*", "matchCriteriaId": "058C7C4B-D692-49DE-924A-C2725A8162D3", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:graalvm:20.3.1.2:*:*:*:enterprise:*:*:*", "matchCriteriaId": "0F0434A5-F2A1-4973-917C-A95F2ABE97D1", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:graalvm:21.0.0.2:*:*:*:enterprise:*:*:*", "matchCriteriaId": "96DD93E0-274E-4C36-99F3-EEF085E57655", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*", "matchCriteriaId": "86305E47-33E9-411C-B932-08C395C09982", "versionEndExcluding": "9.2.6.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*", "matchCriteriaId": "0B1CAD50-749F-4ADB-A046-BF3585677A58", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8782A14-89B0-45EE-A5CB-FF715F5BA379", "versionEndIncluding": "8.0.23", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C40ECC8-933B-47A4-8082-FCF0EF9C973E", "versionEndIncluding": "5.7.33", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "32714AD7-BCD1-4624-9923-5E6D927CF3CB", "versionEndIncluding": "8.0.23", "versionStartIncluding": "8.0.15", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*", "matchCriteriaId": "CB1A94E1-A6C6-488D-A74C-6C0B24637272", "versionEndIncluding": "8.0.23", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*", "matchCriteriaId": "7E1E416B-920B-49A0-9523-382898C2979D", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*", "matchCriteriaId": "D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*", "matchCriteriaId": "C8AF00C6-B97F-414D-A8DF-057E6BFD8597", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:*:*:*:*:*:*:*:*", "matchCriteriaId": "08FA59A8-6A62-4B33-8952-D6E658F8DAC9", "versionEndIncluding": "17.12", "versionStartIncluding": "17.7", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:19.12:*:*:*:*:*:*:*", "matchCriteriaId": "10864586-270E-4ACF-BDCC-ECFCD299305F", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:20.12:*:*:*:*:*:*:*", "matchCriteriaId": "38340E3C-C452-4370-86D4-355B6B4E0A06", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:primavera_unifier:21.12:*:*:*:*:*:*:*", "matchCriteriaId": "E9C55C69-E22E-4B80-9371-5CD821D79FE2", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:secure_backup:*:*:*:*:*:*:*:*", "matchCriteriaId": "C01E8B82-71C7-4A4A-A70A-7B147524AB4A", "versionEndExcluding": "18.1.0.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:secure_global_desktop:5.6:*:*:*:*:*:*:*", "matchCriteriaId": "9DA11710-9EA8-49B4-8FD1-3AEE442F6ADC", "vulnerable": true }, { "criteria": "cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*", "matchCriteriaId": "D3E503FB-6279-4D4A-91D8-E237ECF9D2B0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:sonicwall:sma100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E8B6D50-D482-43E9-A20D-FA77FD59AE2D", "versionEndExcluding": "10.2.1.0-17sv", "versionStartIncluding": "10.2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:sonicwall:sma100:-:*:*:*:*:*:*:*", "matchCriteriaId": "8E4A2B7B-40F5-4AE0-ACC7-E94B82435DBA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:sonicwall:capture_client:3.5:*:*:*:*:*:*:*", "matchCriteriaId": "349EB4AE-65E3-42DC-8F9C-3A1A155324D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:sonicwall:sonicos:7.0.1.0:*:*:*:*:*:*:*", "matchCriteriaId": "2BD8688A-2D55-4A7E-A143-1BD0FCF957B0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_rcm1224_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5081E52B-E7C0-46BD-B1D0-2C70ABCC8831", "versionStartIncluding": "6.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_rcm1224:-:*:*:*:*:*:*:*", "matchCriteriaId": "3747CDD7-E833-4B68-A362-77D6A2E9D888", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "058D21EA-E94C-4DDC-AD92-967DAC934457", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*", "matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "424CD8EA-D8CB-40C7-8E0F-AC4B05C59C99", "versionStartIncluding": "6.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "858B6A84-5D0E-4E23-AE32-A45B51BAC8CF", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D173626B-9C50-489F-8BA4-1C45E5F96526", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E967F5FC-6F3E-4982-8813-CA1DAF3BE165", "versionStartIncluding": "6.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81F315D8-0B26-4442-B330-85124017A482", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*", "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F20F735-7A70-4A24-9621-786F99C8F87D", "versionStartIncluding": "4.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*", "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "973B8030-B630-4D67-B897-25A359A96185", "versionStartIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*", "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86EA8E3F-81BD-47BC-9834-A9B69CA7E70C", "versionStartIncluding": "6.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE116AD9-B55F-41C8-8B55-329809DB63E1", "versionStartIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*", "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E40058B3-3726-4F6A-AB41-7679487639F2", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*", "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*", "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54FBE4D4-F31E-4B61-9216-44C8EC2988AB", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "20511D61-FC1D-453E-BDF6-D3FB9951192A", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*", "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "640AC619-B516-46FC-821B-09C4542A3FD6", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1FB979DB-731B-4693-A9F8-B11ED953717C", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*", "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "886D2FE6-B054-4E3B-BACB-F08C0A119A80", "versionStartIncluding": "1.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "3B185B70-CAC9-47AC-8639-7A4707C21540", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "9FA78457-260C-467B-9785-04B3C8EDF3B3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABEA3BEE-E7AF-4C9A-ADE4-CE7FC1DB7639", "versionStartIncluding": "3.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "049460B8-6186-44F9-B41F-284A2EC0B3B4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "205482DA-548C-4757-91F0-1599438873BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45208694-635A-42AC-B668-8B67C60568B8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4C147D9-4649-4289-B18B-55BD6E33521A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DE4FA1E6-4C5A-4CDC-AD40-E384C0BCA90D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*", "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D254DA1D-C53E-426B-9C69-580CC47CF0AA", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "65278BA0-3C81-4D81-9801-D7BE3A1D7680", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C06A02ED-0BA3-4A2C-AF0C-689B8AEB34B8", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_eu:-:*:*:*:*:*:*:*", "matchCriteriaId": "209C7B1E-10F6-4215-AF69-CC36192E0FCE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_us_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF8C00EE-1154-440C-A223-A2CE99CE3126", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_us:-:*:*:*:*:*:*:*", "matchCriteriaId": "171A9543-E677-422F-8AEA-1BC2D0E53593", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB201DD3-8890-453E-A11E-1E13B3DAB3F9", "versionStartIncluding": "3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-8_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "350FD323-C876-4C7A-A2E7-4B0660C87F6C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61E498B1-87FF-454B-8DF0-61D0D3208491", "versionStartIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1EE2F10-A7A6-486F-AE5C-53AE25BAF200", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90FB801F-11B5-438C-98A1-E928BFEA2ADB", "versionEndExcluding": "3.0", "versionStartIncluding": "2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "F56C2BDC-928E-491A-8E7C-F976B3787C7A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4BA1E6-64F7-4B96-8302-134057DAB1BE", "versionStartIncluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543sp-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "783B50B8-2FB7-4982-88AA-B4F2AD094796", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1545-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCA9544-DD17-4F56-B34C-91A3F37154AF", "versionStartIncluding": "1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1545-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "1256EB4B-DD8A-4F99-AE69-F74E8F789C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_telecontrol_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C25165E-EDE9-42F1-A3B9-0E47630D49CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pcs_7_telecontrol:-:*:*:*:*:*:*:*", "matchCriteriaId": "5BF281FB-26E0-43E4-A2B6-4015661368AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pcs_neo_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6EEACFC9-41B7-4EE0-9427-692363880326", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pcs_neo:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF3CA343-CA2A-4593-930C-158612CE7A55", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pdm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E9AE23E-7DAE-4191-BA4E-A7CD655C4BC8", "versionStartIncluding": "9.1.0.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pdm:-:*:*:*:*:*:*:*", "matchCriteriaId": "E092B735-42D5-48D5-947B-288C0FA2E180", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D874D636-392A-4750-B976-F411DBCEBA8D", "versionStartIncluding": "2019", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "968FBB4E-5B0B-43D4-B3AD-418028093990", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*", "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5212F097-B65A-4D73-BB6F-49687F8AD980", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*", "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D806113B-57EB-4AA0-9D5E-12E30337A93B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "53FA50A7-2DF6-454E-8A8E-838C392AB417", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*", "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*", "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FC628CB7-0816-4267-9C5D-954BD0233D2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "88E64167-16AA-48D7-BCDC-B15D37FA666D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*", "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47F1294A-1C26-4D43-9C53-D833F2510536", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4AF60081-D534-44F5-972F-23257F16F372", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AEF1726E-B56F-4D39-AFF4-E79A3CA00DE6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4948734A-0AAD-4D28-B7FF-FFBBB9AA39C6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6EE37798-B068-40E5-BC03-1D8D303E5926", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E0C491C-5C4A-4F1C-ABD4-9502A54AAA78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E7657063-1296-4734-B108-A2FF7A01B07F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*", "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8C477CCD-06C7-4907-8B0C-4FCE7F6DADAD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_connect_300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3360ACCE-E735-4E34-B278-0D4460E74CBF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_connect_300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7B854F5B-78C7-41FE-9364-5E71B36342A3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D2B20D95-C4B3-4D13-A3D8-F22AC42DC059", "versionEndExcluding": "2.2", "versionStartIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_logon:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6F24E40-F3F0-48F3-B3DC-5F98B0564F7A", "versionStartIncluding": "1.6.0.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_logon:1.5:sp3_update_1:*:*:*:*:*:*", "matchCriteriaId": "423359E5-9C36-4C6B-AB24-B030E6C61D53", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_telecontrol:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3169FD3-CBA2-417C-95EF-4F8AE9FAB5AD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*", "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinec_pni:-:*:*:*:*:*:*:*", "matchCriteriaId": "1353DC31-FB12-427A-B1B2-9164A4BEE14B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:-:*:*:*:*:*:*", "matchCriteriaId": "B0A5CC25-A323-4D49-8989-5A417D12D646", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "A690BCD3-6497-43F7-8A51-E033B9121DC8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "AA375D44-ECC5-4BD3-A3D5-6D2AA68782D5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update1:*:*:*:*:*:*", "matchCriteriaId": "6CD26C73-B61F-424B-91C2-352E2CAE6666", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update2:*:*:*:*:*:*", "matchCriteriaId": "DB4EA15F-ECA4-477F-948F-490FC90BC66A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABA14E65-214C-431D-A49A-D8FC142D4541", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*", "matchCriteriaId": "915B09CB-CA0A-445B-89D3-16AE9B08858E", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253", "versionEndExcluding": "1.0.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "25A3180B-21AF-4010-9DAB-41ADFD2D8031", "versionEndIncluding": "10.12.0", "versionStartIncluding": "10.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*", "matchCriteriaId": "43B199B4-D89C-483D-ACAE-6CB2A59EE67C", "versionEndIncluding": "10.24.0", "versionStartIncluding": "10.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A", "versionEndIncluding": "12.12.0", "versionStartIncluding": "12.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*", "matchCriteriaId": "3DEBF7C8-B000-47B9-B597-DC440F2603B3", "versionEndExcluding": "12.22.1", "versionStartIncluding": "12.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482", "versionEndIncluding": "14.14.0", "versionStartIncluding": "14.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*", "matchCriteriaId": "380D03F3-6A7E-43A2-B002-FB2521FD3C58", "versionEndExcluding": "14.16.1", "versionStartIncluding": "14.15.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*", "matchCriteriaId": "3ED4D313-F372-4CC1-BE11-6BBA2F0E90E3", "versionEndExcluding": "15.14.0", "versionStartIncluding": "15.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)." }, { "lang": "es", "value": "Un servidor OpenSSL TLS puede cometer un fallo si un cliente env\u00eda un mensaje ClientHello de renegociaci\u00f3n dise\u00f1ado maliciosamente.\u0026#xa0;Si una renegociaci\u00f3n de TLSv1.2 ClientHello omite la extensi\u00f3n signature_algorithms (donde estaba presente en el ClientHello inicial), pero incluye una extensi\u00f3n signature_algorithms_cert, se producir\u00e1 una desreferencia del puntero NULL, lo que conllevar\u00e1 un bloqueo y un ataque de denegaci\u00f3n de servicio.\u0026#xa0;Un servidor solo es vulnerable si tiene TLSv1.2 y la renegociaci\u00f3n habilitada (que es la configuraci\u00f3n predeterminada).\u0026#xa0;Los clientes de OpenSSL TLS no est\u00e1n afectados por este problema.\u0026#xa0;Todas las versiones de OpenSSL versi\u00f3n 1.1.1 est\u00e1n afectadas por este problema.\u0026#xa0;Los usuarios de estas versiones deben actualizar a OpenSSL versi\u00f3n 1.1.1k.\u0026#xa0;OpenSSL versi\u00f3n 1.0.2 no est\u00e1 afectado por este problema.\u0026#xa0;Corregido en OpenSSL versi\u00f3n 1.1.1k (Afectadas versiones 1.1.1-1.1.1j)" } ], "id": "CVE-2021-3449", "lastModified": "2024-11-21T06:21:33.050", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-25T15:15:13.450", "references": [ { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "source": "openssl-security@openssl.org", "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "source": "openssl-security@openssl.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "source": "openssl-security@openssl.org", "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "source": "openssl-security@openssl.org", "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "source": "openssl-security@openssl.org", "tags": [ "Vendor Advisory" ], "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-05" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-06" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-09" }, { "source": "openssl-security@openssl.org", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-10" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-05" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-06" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-09" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.tenable.com/security/tns-2021-10" } ], "sourceIdentifier": "openssl-security@openssl.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2021-3449
Vulnerability from cvelistv5
Published
2021-03-25 14:25
Modified
2024-09-17 03:43
Severity ?
EPSS score ?
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T16:53:17.609Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "tags": [ "x_transferred" ], "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "name": "DSA-4875", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "name": "GLSA-202103-03", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "name": "FEDORA-2021-cbf14ab8f9", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-10" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-09" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "tags": [ "x_transferred" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-06" }, { "tags": [ "x_transferred" ], "url": "https://www.tenable.com/security/tns-2021-05" }, { "tags": [ "x_transferred" ], "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "tags": [ "x_transferred" ], "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "tags": [ "x_transferred" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update", "tags": [ "mailing-list", "x_transferred" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "OpenSSL", "vendor": "OpenSSL", "versions": [ { "status": "affected", "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)" } ] } ], "credits": [ { "lang": "en", "value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)" } ], "datePublic": "2021-03-25T00:00:00", "descriptions": [ { "lang": "en", "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)." } ], "metrics": [ { "other": { "content": { "lang": "eng", "url": "https://www.openssl.org/policies/secpolicy.html#High", "value": "High" }, "type": "unknown" } } ], "problemTypes": [ { "descriptions": [ { "description": "NULL pointer dereference", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-21T19:05:57.096577", "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5", "shortName": "openssl" }, "references": [ { "url": "https://www.openssl.org/news/secadv/20210325.txt" }, { "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148" }, { "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021", "tags": [ "vendor-advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd" }, { "name": "DSA-4875", "tags": [ "vendor-advisory" ], "url": "https://www.debian.org/security/2021/dsa-4875" }, { "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1" }, { "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3" }, { "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4" }, { "name": "GLSA-202103-03", "tags": [ "vendor-advisory" ], "url": "https://security.gentoo.org/glsa/202103-03" }, { "name": "FEDORA-2021-cbf14ab8f9", "tags": [ "vendor-advisory" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/" }, { "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "url": "https://www.tenable.com/security/tns-2021-10" }, { "url": "https://www.tenable.com/security/tns-2021-09" }, { "url": "https://security.netapp.com/advisory/ntap-20210513-0002/" }, { "url": "https://security.netapp.com/advisory/ntap-20210326-0006/" }, { "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc" }, { "url": "https://www.tenable.com/security/tns-2021-06" }, { "url": "https://www.tenable.com/security/tns-2021-05" }, { "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356" }, { "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845" }, { "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013" }, { "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update", "tags": [ "mailing-list" ], "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html" }, { "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf" }, { "url": "https://www.oracle.com/security-alerts/cpujul2022.html" }, { "url": "https://security.netapp.com/advisory/ntap-20240621-0006/" } ], "title": "NULL pointer deref in signature_algorithms processing" } }, "cveMetadata": { "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5", "assignerShortName": "openssl", "cveId": "CVE-2021-3449", "datePublished": "2021-03-25T14:25:13.659307Z", "dateReserved": "2021-03-17T00:00:00", "dateUpdated": "2024-09-17T03:43:55.497Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-15786
Vulnerability from cvelistv5
Published
2020-09-09 18:11
Modified
2024-08-04 13:22
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) |
Version: All versions < V16 |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:22:30.857Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16" } ] }, { "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c= V16" } ] }, { "product": "SIMATIC HMI Mobile Panels", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c= V16" } ] }, { "product": "SIMATIC HMI Unified Comfort Panels", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c= V16" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions \u003c V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c= V16), SIMATIC HMI Mobile Panels (All versions \u003c= V16), SIMATIC HMI Unified Comfort Panels (All versions \u003c= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-307", "description": "CWE-307: Improper Restriction of Excessive Authentication Attempts", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-06-08T19:47:15", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-15786", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V16" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c= V16" } ] } }, { "product_name": "SIMATIC HMI Mobile Panels", "version": { "version_data": [ { "version_value": "All versions \u003c= V16" } ] } }, { "product_name": "SIMATIC HMI Unified Comfort Panels", "version": { "version_data": [ { "version_value": "All versions \u003c= V16" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions \u003c V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c= V16), SIMATIC HMI Mobile Panels (All versions \u003c= V16), SIMATIC HMI Unified Comfort Panels (All versions \u003c= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-307: Improper Restriction of Excessive Authentication Attempts" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-15786", "datePublished": "2020-09-09T18:11:39", "dateReserved": "2020-07-15T00:00:00", "dateUpdated": "2024-08-04T13:22:30.857Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7592
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens AG | SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) |
Version: All versions |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.896Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC HMI KTP700F Mobile Arctic", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC HMI Mobile Panels 2nd Generation", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319: Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-16T13:40:34", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7592", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC HMI KTP700F Mobile Arctic", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC HMI Mobile Panels 2nd Generation", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-319: Cleartext Transmission of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7592", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.896Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }