Vulnerabilites related to siemens - simatic_hmi_mobile_panels_firmware
cve-2020-15786
Vulnerability from cvelistv5
Published
2020-09-09 18:11
Modified
2024-08-04 13:22
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
Impacted products
Vendor Product Version
Siemens SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) Version: All versions < V16
Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants) Version: All versions <= V16
Siemens SIMATIC HMI Mobile Panels Version: All versions <= V16
Siemens SIMATIC HMI Unified Comfort Panels Version: All versions <= V16
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:22:30.857Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c= V16"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Mobile Panels",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c= V16"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Unified Comfort Panels",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c= V16"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions \u003c V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c= V16), SIMATIC HMI Mobile Panels (All versions \u003c= V16), SIMATIC HMI Unified Comfort Panels (All versions \u003c= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-307",
              "description": "CWE-307: Improper Restriction of Excessive Authentication Attempts",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-08T19:47:15",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-15786",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c= V16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Mobile Panels",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c= V16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Unified Comfort Panels",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c= V16"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions \u003c V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c= V16), SIMATIC HMI Mobile Panels (All versions \u003c= V16), SIMATIC HMI Unified Comfort Panels (All versions \u003c= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-307: Improper Restriction of Excessive Authentication Attempts"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-15786",
    "datePublished": "2020-09-09T18:11:39",
    "dateReserved": "2020-07-15T00:00:00",
    "dateUpdated": "2024-08-04T13:22:30.857Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2020-09-09 19:15
Modified
2024-11-21 05:06
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04B80487-9B16-451E-914C-52D69D7E68C2",
              "versionEndIncluding": "14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C98A381-02D5-460E-8849-63F4576BC52C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA6D06D6-AA28-47C7-8944-A7500A330311",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55E03180-BE77-4A22-A6C1-FE90B9760570",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_united_comfort_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC20A46A-6B84-48E3-8E53-715F13BDFD4B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_united_comfort_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B1E4ACE-F6FE-4706-9720-89C3773AFDC4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions \u003c V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c= V16), SIMATIC HMI Mobile Panels (All versions \u003c= V16), SIMATIC HMI Unified Comfort Panels (All versions \u003c= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (Todas las versiones anteriores V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (Todas las versiones anteriores o iguales a la versi\u00f3nV16), SIMATIC HMI Mobile Panels (Todas las versiones anteriores o iguales a la versi\u00f3nV16), SIMATIC HMI Unified Comfort Panels (Todas las versiones anteriores o iguales a la versi\u00f3nV16). Los dispositivos afectados bloquean de forma insuficiente los intentos de autenticaci\u00f3n excesivos. Esto podr\u00eda permitir a un atacante remoto detectar las contrase\u00f1as de los usuarios y obtener acceso al Servidor Sm@rt mediante un ataque de fuerza bruta"
    }
  ],
  "id": "CVE-2020-15786",
  "lastModified": "2024-11-21T05:06:10.660",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-09-09T19:15:19.787",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-307"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-307"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}