CWE-319
AllowedCleartext Transmission of Sensitive Information
Abstraction: Base · Status: Draft
The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.
1147 vulnerabilities reference this CWE, most recent first.
CVE-2025-3329 (GCVE-0-2025-3329)
Vulnerability from cvelistv5 – Published: 2025-04-07 01:00 – Updated: 2025-04-07 13:53| URL | Tags |
|---|---|
| https://vuldb.com/?id.303543 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.303543 | signaturepermissions-required |
| https://vuldb.com/?submit.551790 | third-party-advisory |
| https://medium.com/@davimouar/from-order-to-explo… | exploit |
| Vendor | Product | Version | |
|---|---|---|---|
| Consumer | Comanda Mobile |
Affected:
14.9.3.0
Affected: 14.9.3.1 Affected: 14.9.3.2 Affected: 15.0.0.0 Affected: 15.0.0.1 Affected: 15.0.0.2 Affected: 15.0.0.3 Affected: 15.0.0.4 Affected: 15.0.0.5 Affected: 15.0.0.6 Affected: 15.0.0.7 Affected: 15.0.0.8 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3329",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-07T13:53:17.245190Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-07T13:53:20.715Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://vuldb.com/?submit.551790"
},
{
"tags": [
"exploit"
],
"url": "https://medium.com/@davimouar/from-order-to-exploit-a-deep-dive-into-restaurant-network-security-64aeaf3a6f64"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Restaurant Order Handler"
],
"product": "Comanda Mobile",
"vendor": "Consumer",
"versions": [
{
"status": "affected",
"version": "14.9.3.0"
},
{
"status": "affected",
"version": "14.9.3.1"
},
{
"status": "affected",
"version": "14.9.3.2"
},
{
"status": "affected",
"version": "15.0.0.0"
},
{
"status": "affected",
"version": "15.0.0.1"
},
{
"status": "affected",
"version": "15.0.0.2"
},
{
"status": "affected",
"version": "15.0.0.3"
},
{
"status": "affected",
"version": "15.0.0.4"
},
{
"status": "affected",
"version": "15.0.0.5"
},
{
"status": "affected",
"version": "15.0.0.6"
},
{
"status": "affected",
"version": "15.0.0.7"
},
{
"status": "affected",
"version": "15.0.0.8"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "davimo (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic has been found in Consumer Comanda Mobile up to 14.9.3.2/15.0.0.8. This affects an unknown part of the component Restaurant Order Handler. The manipulation of the argument Login/Password leads to cleartext transmission of sensitive information. The attack can only be initiated within the local network. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Consumer Comanda Mobile bis 14.9.3.2/15.0.0.8 entdeckt. Sie wurde als problematisch eingestuft. Dabei betrifft es einen unbekannter Codeteil der Komponente Restaurant Order Handler. Durch das Beeinflussen des Arguments Login/Password mit unbekannten Daten kann eine cleartext transmission of sensitive information-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei im lokalen Netzwerk erfolgen. Die Komplexit\u00e4t eines Angriffs ist eher hoch. Sie ist schwierig auszunutzen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 2.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 3.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 3.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 1.8,
"vectorString": "AV:A/AC:H/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-310",
"description": "Cryptographic Issues",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-07T01:00:14.297Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303543 | Consumer Comanda Mobile Restaurant Order cleartext transmission",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.303543"
},
{
"name": "VDB-303543 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303543"
},
{
"name": "Submit #551790 | Consumer Comanda Mobile 14.7.1.4 \u2013 15.0.0.8 Improper Authorization",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.551790"
},
{
"tags": [
"exploit"
],
"url": "https://medium.com/@davimouar/from-order-to-exploit-a-deep-dive-into-restaurant-network-security-64aeaf3a6f64"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-06T14:28:14.000Z",
"value": "VulDB entry last update"
}
],
"title": "Consumer Comanda Mobile Restaurant Order cleartext transmission"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3329",
"datePublished": "2025-04-07T01:00:14.297Z",
"dateReserved": "2025-04-06T12:23:03.859Z",
"dateUpdated": "2025-04-07T13:53:20.715Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2861 (GCVE-0-2025-2861)
Vulnerability from cvelistv5 – Published: 2025-03-28 13:11 – Updated: 2025-04-03 12:58- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Arteche | saTECH BCU |
Affected:
2.1.3
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2861",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-28T13:35:01.742369Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-03T12:58:35.556Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "saTECH BCU",
"vendor": "Arteche",
"versions": [
{
"status": "affected",
"version": "2.1.3"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Aar\u00f3n Flecha"
},
{
"lang": "en",
"type": "finder",
"value": "Gabriel V\u00eda Echezarreta"
}
],
"datePublic": "2025-03-27T11:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SaTECH BCU in its firmware version 2.1.3 uses the HTTP protocol. The use of the HTTP protocol for web browsing has the problem that information is exchanged in unencrypted text. Since sensitive data such as credentials are exchanged, an attacker could obtain them and log in legitimately."
}
],
"value": "SaTECH BCU in its firmware version 2.1.3 uses the HTTP protocol. The use of the HTTP protocol for web browsing has the problem that information is exchanged in unencrypted text. Since sensitive data such as credentials are exchanged, an attacker could obtain them and log in legitimately."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-28T13:11:29.282Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-arteches-satech-bcu"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been fixed by Arteche in firmware version 2.2.1."
}
],
"value": "The vulnerability has been fixed by Arteche in firmware version 2.2.1."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Cleartext Transmission of Sensitive Information vulnerability in saTECH BCU",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-2861",
"datePublished": "2025-03-28T13:11:29.282Z",
"dateReserved": "2025-03-27T10:59:42.618Z",
"dateUpdated": "2025-04-03T12:58:35.556Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2818 (GCVE-0-2025-2818)
Vulnerability from cvelistv5 – Published: 2025-07-17 19:17 – Updated: 2025-07-17 20:11- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Motorola | Smart Connect Android Application |
Affected:
0 , < 08.0.1.011.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2818",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-17T20:11:21.730503Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-17T20:11:30.889Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smart Connect Android Application",
"vendor": "Motorola",
"versions": [
{
"lessThan": "08.0.1.011.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:motorola:smart_connect:*:*:*:*:*:android:*:*",
"versionEndExcluding": "08.0.1.011.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Motorola/Lenovo thanks MS. Candidate Bai Xingyu, Ph.D. Candidate Liu Xiaofeng, Ph.D. Candidate Song Xiangpu, Prof. Hu Chengyu, Prof. Guo Shanqing from Shandong University for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA vulnerability was reported in version 1.0 of the Bluetooth Transmission Alliance protocol adopted by Motorola Smart Connect Android Application that could allow a nearby attacker within the Bluetooth interaction range to intercept files when transferred to a device not paired in Smart Connect. \u003cbr\u003e\u003c/p\u003e"
}
],
"value": "A vulnerability was reported in version 1.0 of the Bluetooth Transmission Alliance protocol adopted by Motorola Smart Connect Android Application that could allow a nearby attacker within the Bluetooth interaction range to intercept files when transferred to a device not paired in Smart Connect."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-17T19:17:51.443Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://en-us.support.motorola.com/app/answers/detail/a_id/186727"
},
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-188742"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpdate Motorola Smart Connect Android Application to version 08.0.1.011.0 (or newer).\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Update Motorola Smart Connect Android Application to version 08.0.1.011.0 (or newer)."
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2025-2818",
"datePublished": "2025-07-17T19:17:51.443Z",
"dateReserved": "2025-03-26T14:25:01.182Z",
"dateUpdated": "2025-07-17T20:11:30.889Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-2311 (GCVE-0-2025-2311)
Vulnerability from cvelistv5 – Published: 2025-03-20 11:55 – Updated: 2026-06-06 06:14| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-25-0074 | government-resourcebroken-link |
| https://siberguvenlik.gov.tr/guvenlik-bildirimler… | government-resource |
| Vendor | Product | Version | |
|---|---|---|---|
| Sechard Information Technologies | SecHard |
Affected:
0 , < 3.3.0.20220411
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2311",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-20T13:01:52.171386Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-20T13:05:28.736Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SecHard",
"vendor": "Sechard Information Technologies",
"versions": [
{
"lessThan": "3.3.0.20220411",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Berat Ugur DEMIRKAN"
},
{
"lang": "en",
"type": "sponsor",
"value": "BG-TEK Cyber Security"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Incorrect Use of Privileged APIs, Cleartext Transmission of Sensitive Information, Insufficiently Protected Credentials vulnerability in Sechard Information Technologies SecHard allows Authentication Bypass, Interface Manipulation, Authentication Abuse, Harvesting Information via API Event Monitoring.\u003cp\u003eThis issue affects SecHard: before 3.3.0.20220411.\u003c/p\u003e"
}
],
"value": "Incorrect Use of Privileged APIs, Cleartext Transmission of Sensitive Information, Insufficiently Protected Credentials vulnerability in Sechard Information Technologies SecHard allows Authentication Bypass, Interface Manipulation, Authentication Abuse, Harvesting Information via API Event Monitoring.\n\nThis issue affects SecHard: before 3.3.0.20220411."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
},
{
"capecId": "CAPEC-113",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-113 Interface Manipulation"
}
]
},
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
},
{
"capecId": "CAPEC-383",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-383 Harvesting Information via API Event Monitoring"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-648",
"description": "CWE-648 Incorrect Use of Privileged APIs",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-06T06:14:52.819Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"government-resource",
"broken-link"
],
"url": "https://www.usom.gov.tr/bildirim/tr-25-0074"
},
{
"tags": [
"government-resource"
],
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-25-0074"
}
],
"source": {
"advisory": "TR-25-0074",
"defect": [
"TR-25-0074"
],
"discovery": "UNKNOWN"
},
"title": "Authentication Bypass in Sechard Information Technologies\u0027 SecHard",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2025-2311",
"datePublished": "2025-03-20T11:55:51.628Z",
"dateReserved": "2025-03-14T13:25:01.277Z",
"dateUpdated": "2026-06-06T06:14:52.819Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-1060 (GCVE-0-2025-1060)
Vulnerability from cvelistv5 – Published: 2025-02-13 05:53 – Updated: 2025-02-13 15:57- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | ASCO 5310 Single-Channel Remote Annunciator |
Affected:
All versions
|
|
| Schneider Electric | ASCO 5350 Eight Channel Remote Annunciator |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1060",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-13T15:57:29.829889Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T15:57:42.661Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ASCO 5310 Single-Channel Remote Annunciator",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ASCO 5350 Eight Channel Remote Annunciator",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure\nof data when network traffic is being sniffed by an attacker.\n\n\n\n\u003cbr\u003e"
}
],
"value": "CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure\nof data when network traffic is being sniffed by an attacker."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-13T05:53:14.338Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=sevd-2025-042-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-042-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-1060",
"datePublished": "2025-02-13T05:53:14.338Z",
"dateReserved": "2025-02-05T13:09:13.862Z",
"dateUpdated": "2025-02-13T15:57:42.661Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-0784 (GCVE-0-2025-0784)
Vulnerability from cvelistv5 – Published: 2025-01-28 20:00 – Updated: 2025-02-12 20:01| URL | Tags |
|---|---|
| https://vuldb.com/?id.293908 | vdb-entry |
| https://vuldb.com/?ctiid.293908 | signaturepermissions-required |
| https://vuldb.com/?submit.483835 | third-party-advisory |
| https://eldruin.notion.site/Intelbras-InControl-v… | exploit |
| Vendor | Product | Version | |
|---|---|---|---|
| Intelbras | InControl |
Affected:
2.21.0
Affected: 2.21.1 Affected: 2.21.2 Affected: 2.21.3 Affected: 2.21.4 Affected: 2.21.5 Affected: 2.21.6 Affected: 2.21.7 Affected: 2.21.8 Affected: 2.21.9 Affected: 2.21.10 Affected: 2.21.11 Affected: 2.21.12 Affected: 2.21.13 Affected: 2.21.14 Affected: 2.21.15 Affected: 2.21.16 Affected: 2.21.17 Affected: 2.21.18 Affected: 2.21.19 Affected: 2.21.20 Affected: 2.21.21 Affected: 2.21.22 Affected: 2.21.23 Affected: 2.21.24 Affected: 2.21.25 Affected: 2.21.26 Affected: 2.21.27 Affected: 2.21.28 Affected: 2.21.29 Affected: 2.21.30 Affected: 2.21.31 Affected: 2.21.32 Affected: 2.21.33 Affected: 2.21.34 Affected: 2.21.35 Affected: 2.21.36 Affected: 2.21.37 Affected: 2.21.38 Affected: 2.21.39 Affected: 2.21.40 Affected: 2.21.41 Affected: 2.21.42 Affected: 2.21.43 Affected: 2.21.44 Affected: 2.21.45 Affected: 2.21.46 Affected: 2.21.47 Affected: 2.21.48 Affected: 2.21.49 Affected: 2.21.50 Affected: 2.21.51 Affected: 2.21.52 Affected: 2.21.53 Affected: 2.21.54 Affected: 2.21.55 Affected: 2.21.56 Affected: 2.21.57 Affected: 2.21.58 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0784",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-28T20:32:08.923755Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:01:10.799Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Registered User Handler"
],
"product": "InControl",
"vendor": "Intelbras",
"versions": [
{
"status": "affected",
"version": "2.21.0"
},
{
"status": "affected",
"version": "2.21.1"
},
{
"status": "affected",
"version": "2.21.2"
},
{
"status": "affected",
"version": "2.21.3"
},
{
"status": "affected",
"version": "2.21.4"
},
{
"status": "affected",
"version": "2.21.5"
},
{
"status": "affected",
"version": "2.21.6"
},
{
"status": "affected",
"version": "2.21.7"
},
{
"status": "affected",
"version": "2.21.8"
},
{
"status": "affected",
"version": "2.21.9"
},
{
"status": "affected",
"version": "2.21.10"
},
{
"status": "affected",
"version": "2.21.11"
},
{
"status": "affected",
"version": "2.21.12"
},
{
"status": "affected",
"version": "2.21.13"
},
{
"status": "affected",
"version": "2.21.14"
},
{
"status": "affected",
"version": "2.21.15"
},
{
"status": "affected",
"version": "2.21.16"
},
{
"status": "affected",
"version": "2.21.17"
},
{
"status": "affected",
"version": "2.21.18"
},
{
"status": "affected",
"version": "2.21.19"
},
{
"status": "affected",
"version": "2.21.20"
},
{
"status": "affected",
"version": "2.21.21"
},
{
"status": "affected",
"version": "2.21.22"
},
{
"status": "affected",
"version": "2.21.23"
},
{
"status": "affected",
"version": "2.21.24"
},
{
"status": "affected",
"version": "2.21.25"
},
{
"status": "affected",
"version": "2.21.26"
},
{
"status": "affected",
"version": "2.21.27"
},
{
"status": "affected",
"version": "2.21.28"
},
{
"status": "affected",
"version": "2.21.29"
},
{
"status": "affected",
"version": "2.21.30"
},
{
"status": "affected",
"version": "2.21.31"
},
{
"status": "affected",
"version": "2.21.32"
},
{
"status": "affected",
"version": "2.21.33"
},
{
"status": "affected",
"version": "2.21.34"
},
{
"status": "affected",
"version": "2.21.35"
},
{
"status": "affected",
"version": "2.21.36"
},
{
"status": "affected",
"version": "2.21.37"
},
{
"status": "affected",
"version": "2.21.38"
},
{
"status": "affected",
"version": "2.21.39"
},
{
"status": "affected",
"version": "2.21.40"
},
{
"status": "affected",
"version": "2.21.41"
},
{
"status": "affected",
"version": "2.21.42"
},
{
"status": "affected",
"version": "2.21.43"
},
{
"status": "affected",
"version": "2.21.44"
},
{
"status": "affected",
"version": "2.21.45"
},
{
"status": "affected",
"version": "2.21.46"
},
{
"status": "affected",
"version": "2.21.47"
},
{
"status": "affected",
"version": "2.21.48"
},
{
"status": "affected",
"version": "2.21.49"
},
{
"status": "affected",
"version": "2.21.50"
},
{
"status": "affected",
"version": "2.21.51"
},
{
"status": "affected",
"version": "2.21.52"
},
{
"status": "affected",
"version": "2.21.53"
},
{
"status": "affected",
"version": "2.21.54"
},
{
"status": "affected",
"version": "2.21.55"
},
{
"status": "affected",
"version": "2.21.56"
},
{
"status": "affected",
"version": "2.21.57"
},
{
"status": "affected",
"version": "2.21.58"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "eldruin (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Intelbras InControl up to 2.21.58 and classified as problematic. This vulnerability affects unknown code of the file /v1/usuario/ of the component Registered User Handler. The manipulation leads to cleartext transmission of sensitive information. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 2.21.59 is able to address this issue. It is recommended to upgrade the affected component."
},
{
"lang": "de",
"value": "In Intelbras InControl bis 2.21.58 wurde eine problematische Schwachstelle gefunden. Dabei geht es um eine nicht genauer bekannte Funktion der Datei /v1/usuario/ der Komponente Registered User Handler. Durch Beeinflussen mit unbekannten Daten kann eine cleartext transmission of sensitive information-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Die Komplexit\u00e4t eines Angriffs ist eher hoch. Das Ausnutzen gilt als schwierig. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung. Ein Aktualisieren auf die Version 2.21.59 vermag dieses Problem zu l\u00f6sen. Als bestm\u00f6gliche Massnahme wird das Einspielen eines Upgrades empfohlen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 2.6,
"vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-310",
"description": "Cryptographic Issues",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T20:00:13.220Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-293908 | Intelbras InControl Registered User usuario cleartext transmission",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.293908"
},
{
"name": "VDB-293908 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.293908"
},
{
"name": "Submit #483835 | Intelbras InControl 2.21.57 Cleartext Transmission of Sensitive Information",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.483835"
},
{
"tags": [
"exploit"
],
"url": "https://eldruin.notion.site/Intelbras-InControl-v2-21-57-Password-exposed-in-clear-text-17d27474cccb806fba1efda195c78258?pvs=4"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-01-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-01-28T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-01-28T15:05:34.000Z",
"value": "VulDB entry last update"
}
],
"title": "Intelbras InControl Registered User usuario cleartext transmission"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-0784",
"datePublished": "2025-01-28T20:00:13.220Z",
"dateReserved": "2025-01-28T13:59:47.508Z",
"dateUpdated": "2025-02-12T20:01:10.799Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-0631 (GCVE-0-2025-0631)
Vulnerability from cvelistv5 – Published: 2025-01-28 18:27 – Updated: 2025-02-06 21:26- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | PowerFlex 755 |
Affected:
<=16.002.279
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0631",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-28T18:57:46.274914Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T21:26:17.072Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerFlex 755",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=16.002.279"
}
]
}
],
"datePublic": "2025-01-28T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eA Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text.\u003c/span\u003e\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text."
}
],
"impacts": [
{
"capecId": "CAPEC-157",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-157 Sniffing Attacks"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T18:27:32.084Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1717.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to v20.3.407"
}
],
"value": "Upgrade to v20.3.407"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "PowerFlex\u00ae 755 Credential Exposure Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-0631",
"datePublished": "2025-01-28T18:27:32.084Z",
"dateReserved": "2025-01-21T21:21:05.171Z",
"dateUpdated": "2025-02-06T21:26:17.072Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-0556 (GCVE-0-2025-0556)
Vulnerability from cvelistv5 – Published: 2025-02-12 15:11 – Updated: 2025-02-12 15:33- CWE-319 - Cleartext Transmission of Sensitive Information
| URL | Tags |
|---|---|
| https://docs.telerik.com/report-server/knowledge-… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Progress Software | Telerik Report Server |
Affected:
1.0.0 , < 2025 Q1 (11.0.25.211)
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0556",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-12T15:33:21.152666Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T15:33:35.788Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
".NET Framework Implementation"
],
"platforms": [
"Windows"
],
"product": "Telerik Report Server",
"vendor": "Progress Software",
"versions": [
{
"lessThan": "2025 Q1 (11.0.25.211)",
"status": "affected",
"version": "1.0.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn Progress\u00ae Telerik\u00ae Report Server, versions prior to 2025 Q1 (11.0.25.211) when using the older .NET Framework implementation, communication of non-sensitive information between the service agent process and app host process occurs over an unencrypted tunnel, which can be subjected to local network traffic sniffing.\u003c/p\u003e"
}
],
"value": "In Progress\u00ae Telerik\u00ae Report Server, versions prior to 2025 Q1 (11.0.25.211) when using the older .NET Framework implementation, communication of non-sensitive information between the service agent process and app host process occurs over an unencrypted tunnel, which can be subjected to local network traffic sniffing."
}
],
"impacts": [
{
"capecId": "CAPEC-158",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-158 Sniffing Network Traffic"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T15:11:03.067Z",
"orgId": "f9fea0b6-671e-4eea-8fde-31911902ae05",
"shortName": "ProgressSoftware"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://docs.telerik.com/report-server/knowledge-base/kb-security-cleartext-transmission-cve-2025-0556"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Telerik Report Server Clear Text Transmission of Agent Commands",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f9fea0b6-671e-4eea-8fde-31911902ae05",
"assignerShortName": "ProgressSoftware",
"cveId": "CVE-2025-0556",
"datePublished": "2025-02-12T15:11:03.067Z",
"dateReserved": "2025-01-17T19:39:39.461Z",
"dateUpdated": "2025-02-12T15:33:35.788Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-0432 (GCVE-0-2025-0432)
Vulnerability from cvelistv5 – Published: 2025-01-28 15:56 – Updated: 2025-01-28 16:32- CWE-319 - Cleartext Transmission of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| HMS Networks | Ewon Flexy 202 |
Affected:
All
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0432",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-28T16:32:09.044151Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T16:32:42.081Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Ewon Flexy 202",
"vendor": "HMS Networks",
"versions": [
{
"status": "affected",
"version": "All"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Khalid Markar, Parul Sindhwad and Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai, India reported this vulnerability to CISA"
}
],
"datePublic": "2025-01-23T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eEWON Flexy 202 transmits user credentials in clear text with no encryption when a user is added, or user credentials are changed via its webpage.\u003c/span\u003e"
}
],
"value": "EWON Flexy 202 transmits user credentials in clear text with no encryption when a user is added, or user credentials are changed via its webpage."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T15:56:10.373Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-023-06"
},
{
"url": "https://www.hms-networks.com/cyber-security"
},
{
"url": "https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/ewon/manuals-and-guides---installation-guides/best-practices-for-a-secure-usage-of-the-ewon-solution-en.pdf?sfvrsn=37160847_4"
},
{
"url": "https://support.hms-networks.com/hc/en-us/articles/19393244940818-How-to-block-all-the-unused-Ewon-Flexy-Cosy131-services-on-the-LAN-WAN-and-or-VPN-interface"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "HMS Networks Ewon Flexy 202 Cleartext Transmission of Sensitive Information",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo ensure the highest level of security when using the Ewon Flexy device, HMS strongly recommend following these best practices:\u003c/p\u003e\u003cul\u003e\u003cli\u003eIntegrate with Talk2M Cloud: Always use the Flexy device in conjunction with Talk2M cloud. This guarantees a robust security level for your remote access connections.\u003c/li\u003e\u003cli\u003eFollow the the guidelines outlined here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/ewon/manuals-and-guides---installation-guides/best-practices-for-a-secure-usage-of-the-ewon-solution-en.pdf?sfvrsn=37160847_4\"\u003eBest Practices for Secure Usage of the Ewon Solution\u003c/a\u003e\u003c/li\u003e\u003cli\u003eDisable Unused Protocols: Regularly review and disable any unsecure protocols that are not in use. Learn how to do this here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.hms-networks.com/hc/en-us/articles/19393244940818-How-to-block-all-the-unused-Ewon-Flexy-Cosy131-services-on-the-LAN-WAN-and-or-VPN-interface\"\u003eHow to Block Unused Ewon Services\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor further information, please visit the HMS \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.hms-networks.com/cyber-security\"\u003eSecurity Advisories\u003c/a\u003e\u0026nbsp;page.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "To ensure the highest level of security when using the Ewon Flexy device, HMS strongly recommend following these best practices:\n\n * Integrate with Talk2M Cloud: Always use the Flexy device in conjunction with Talk2M cloud. This guarantees a robust security level for your remote access connections.\n * Follow the the guidelines outlined here: Best Practices for Secure Usage of the Ewon Solution https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/ewon/manuals-and-guides---installation-guides/best-practices-for-a-secure-usage-of-the-ewon-solution-en.pdf \n * Disable Unused Protocols: Regularly review and disable any unsecure protocols that are not in use. Learn how to do this here: How to Block Unused Ewon Services https://support.hms-networks.com/hc/en-us/articles/19393244940818-How-to-block-all-the-unused-Ewon-Flexy-Cosy131-services-on-the-LAN-WAN-and-or-VPN-interface \n\n\nFor further information, please visit the HMS Security Advisories https://www.hms-networks.com/cyber-security \u00a0page."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-0432",
"datePublished": "2025-01-28T15:56:10.373Z",
"dateReserved": "2025-01-13T21:36:12.484Z",
"dateUpdated": "2025-01-28T16:32:42.081Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-0252 (GCVE-0-2025-0252)
Vulnerability from cvelistv5 – Published: 2025-07-25 00:08 – Updated: 2025-07-25 13:19- CWE-319 - Cleartext Transmission of Sensitive Information
| URL | Tags |
|---|---|
| https://support.hcl-software.com/csm?id=kb_articl… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| HCL Software | IEM |
Affected:
1.2
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0252",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-25T13:18:50.215903Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-25T13:19:00.610Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IEM",
"vendor": "HCL Software",
"versions": [
{
"status": "affected",
"version": "1.2"
}
]
}
],
"datePublic": "2025-07-24T23:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "HCL IEM is affected by a password in cleartext vulnerability.\u0026nbsp; Sensitive information is transmitted without adequate protection, potentially exposing it to unauthorized access during transit."
}
],
"value": "HCL IEM is affected by a password in cleartext vulnerability.\u00a0 Sensitive information is transmitted without adequate protection, potentially exposing it to unauthorized access during transit."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.6,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-25T00:19:29.552Z",
"orgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
"shortName": "HCL"
},
"references": [
{
"name": "VDB-299060 | PyTorch Quantized Sigmoid Module nnq_Sigmoid initialization",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hcl-software.com/csm?id=kb_article\u0026sysparm_article=KB0122368"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "HCL IEM is affected by a password in cleartext vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
"assignerShortName": "HCL",
"cveId": "CVE-2025-0252",
"datePublished": "2025-07-25T00:08:13.901Z",
"dateReserved": "2025-01-06T16:00:27.548Z",
"dateUpdated": "2025-07-25T13:19:00.610Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Before transmitting, encrypt the data using reliable, confidentiality-protecting cryptographic protocols.
Mitigation
When using web applications with SSL, use SSL for the entire session from login to logout, not just for the initial login page.
Mitigation
When designing hardware platforms, ensure that approved encryption algorithms (such as those recommended by NIST) protect paths from security critical data to trusted user applications.
Mitigation
Use tools and techniques that require manual (human) analysis, such as penetration testing, threat modeling, and interactive tools that allow the tester to record and modify an active session. These may be more effective than strictly automated techniques. This is especially the case with weaknesses that are related to design and business rules.
Mitigation
Configure servers to use encrypted channels for communication, which may include SSL or other secure protocols.
CAPEC-102: Session Sidejacking
Session sidejacking takes advantage of an unencrypted communication channel between a victim and target system. The attacker sniffs traffic on a network looking for session tokens in unencrypted traffic. Once a session token is captured, the attacker performs malicious actions by using the stolen token with the targeted application to impersonate the victim. This attack is a specific method of session hijacking, which is exploiting a valid session token to gain unauthorized access to a target system or information. Other methods to perform a session hijacking are session fixation, cross-site scripting, or compromising a user or server machine and stealing the session token.
CAPEC-117: Interception
An adversary monitors data streams to or from the target for information gathering purposes. This attack may be undertaken to solely gather sensitive information or to support a further attack against the target. This attack pattern can involve sniffing network traffic as well as other types of data streams (e.g. radio). The adversary can attempt to initiate the establishment of a data stream or passively observe the communications as they unfold. In all variants of this attack, the adversary is not the intended recipient of the data stream. In contrast to other means of gathering information (e.g., targeting data leaks), the adversary must actively position themself so as to observe explicit data channels (e.g. network traffic) and read the content. However, this attack differs from a Adversary-In-the-Middle (CAPEC-94) attack, as the adversary does not alter the content of the communications nor forward data to the intended recipient.
CAPEC-383: Harvesting Information via API Event Monitoring
An adversary hosts an event within an application framework and then monitors the data exchanged during the course of the event for the purpose of harvesting any important data leaked during the transactions. One example could be harvesting lists of usernames or userIDs for the purpose of sending spam messages to those users. One example of this type of attack involves the adversary creating an event within the sub-application. Assume the adversary hosts a "virtual sale" of rare items. As other users enter the event, the attacker records via AiTM (CAPEC-94) proxy the user_ids and usernames of everyone who attends. The adversary would then be able to spam those users within the application using an automated script.
CAPEC-477: Signature Spoofing by Mixing Signed and Unsigned Content
An attacker exploits the underlying complexity of a data structure that allows for both signed and unsigned content, to cause unsigned data to be processed as though it were signed data.
CAPEC-65: Sniff Application Code
An adversary passively sniffs network communications and captures application code bound for an authorized client. Once obtained, they can use it as-is, or through reverse-engineering glean sensitive information or exploit the trust relationship between the client and server. Such code may belong to a dynamic update to the client, a patch being applied to a client component or any such interaction where the client is authorized to communicate with the server.